Buhler Technologies Zirconia oxygen analyzer BA 1000 Instruction Manual
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Lesen Sie die Bedienungsanleitung vor dem Gebrauch des Gerätes gründlich durch, insbesondere die Hinweise unter Gliederungspunkt 2. Andernfalls könnten Gesundheits- oder Sachschäden auftreten. Die Bühler Technologies GmbH haftet nicht bei eigenmächtigen Änderungen des Gerätes oder für unsachgemäßen Gebrauch. Read this instruction carefully prior to installation and/or use. Pay attention particularly to all advice and safety instructions to prevent injuries. Bühler Technologies GmbH cannot be held responsible for misusing the product or unreliable function due to unauthorised modifications. BX550001, 10/2011 Art. Nr. 9031098 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax. +49 (0) 21 02 / 49 89-20 Internet: www.buehler-technologies.com Email: analyse@buehler-technologies.com 1 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Inhaltsverzeichnis Seite 1  Einleitung ............................................................................................................................. 4  2  Wichtige Hinweise ............................................................................................................... 4  3  Transport und Lagerungsvorschriften .............................................................................. 6  4  Aufbauen und Anschließen ................................................................................................ 6  4.1  Elektrischer Anschluss ......................................................................................................................7  4.2  Einschraubverschraubung ................................................................................................................9  4.3  Einstellung der Grenzwertkontakte beim BA 1000 D 230 G ...........................................................10  5  Betrieb und Wartung ......................................................................................................... 11  5.1  Warnhinweise ..................................................................................................................................11  5.2  Inbetriebnahme ...............................................................................................................................11  5.2.1  Grundeinstellung .........................................................................................................................12  5.2.2  Kalibrierung .................................................................................................................................12  5.3  Wartung ...........................................................................................................................................13  5.3.1  Auswechseln der Schmelzsicherung ..........................................................................................13  5.4  Besonderheiten des BA 1000 S IP 66 zum Einsatz in Kompostmieten ..........................................14  6  Instandsetzung und Entsorgung ..................................................................................... 14  6.1  Entsorgung ......................................................................................................................................14  7  7.1  7.2  7.3  2 Anhang ............................................................................................................................... 15  Ersatzteile und Zubehör ..................................................................................................................15  Gewährleistung ...............................................................................................................................15  Beigefügte Dokumente ....................................................................................................................15  BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Contents Page 1  Introduction ........................................................................................................................16  2  Important advice ................................................................................................................16  3  Transport and storing regulations ...................................................................................17  4  Installation and connection ..............................................................................................17  4.1  Electrical connection ....................................................................................................................... 17  4.2  Screw-in threaded joint ................................................................................................................... 20  4.3  Adjustment of the limit contacts of the BA 1000 D 230 G ............................................................... 21  5  Operation and maintenance..............................................................................................22  5.1  Indication of risk .............................................................................................................................. 22  5.2  Starting ............................................................................................................................................ 22  5.2.1  Basic setting ................................................................................................................................ 23  5.2.2  Calibration ................................................................................................................................... 23  5.3  Maintenance .................................................................................................................................... 24  5.3.1  Replacing the fuse ...................................................................................................................... 24  5.4  Additional hints for BA 1000 S IP66 for decomposition .................................................................. 24  6  Repair and disposal ...........................................................................................................25  6.1  Disposal........................................................................................................................................... 25  7  7.1  7.2  7.3  Appendix.............................................................................................................................26  Spare parts and accessories .......................................................................................................... 26  Warranty .......................................................................................................................................... 26  Attached documents ....................................................................................................................... 26  BX550001, 10/2011 Art. Nr. 9031098 3 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 1 Einleitung Der BA 1000 dient der Analyse des Sauerstoffanteils in Gasgemischen. Das Gerät darf nur in einwandfreiem Zustand unter Beachtung der Bedienungsanleitung betrieben werden. Es ist nicht zum Einsatz in zündfähigen Gasgemischen oder explosionsgefährdeter Umgebung geeignet. Bitte beachten Sie die Angaben der Datenblätter hinsichtlich spezifischen Verwendungszwecks, vorhandener Werkstoffkombinationen sowie Druck- und Temperaturgrenzen. Der BA 1000 S IP66 ist gedacht für die Überwachung des Sauerstoffgehaltes in Kompostmieten während des Verrottungsprozesses. Die Sonde ist ausgestattet mit einer feuchtebeständigen Membran sowie mit einer durch ein IP 66 Gehäuse geschützten Elektronik. Die Sondenlänge beträgt 220 mm. Die Erläuterung der Besonderheiten des BA 1000 S IP66 finden Sie in Kapitel 5.4. 2 Wichtige Hinweise Bitte überprüfen Sie vor Einbau des Gerätes, ob die genannten technischen Daten den Anwendungsparametern entsprechen. Überprüfen Sie ebenfalls, ob alle zum Lieferumfang gehörenden Teile vollständig vorhanden sind. Der Einsatz der Geräte ist nur zulässig, wenn: - das Produkt unter den in der Bedienungs- und Installationsanleitung beschriebenen Bedingungen, dem Einsatz gemäß Typenschild und für Anwendungen, für die es vorgesehen ist, verwendet wird. - die im Datenblatt und der Anleitung angegebenen Grenzwerte eingehalten werden. - Überwachungsvorrichtungen/ Schutzvorrichtung korrekt angeschlossen sind. - die Service- und Reparaturarbeiten, die nicht in dieser Anleitung beschrieben sind, von Bühler Technologies GmbH durchgeführt werden. - Originalersatzteile verwendet werden. Diese Bedienungsanleitung ist Teil des Betriebsmittels. Der Hersteller behält sich das Recht vor, die Leistungs-, die Spezifikations- oder die Auslegungsdaten ohne Vorankündigung zu ändern. Bewahren Sie die Anleitung für den späteren Gebrauch auf. Begriffsbestimmungen für Warnhinweise: HINWEIS Signalwort für wichtige Information zum Produkt, auf die im besonderen Maße aufmerksam gemacht werden soll. VORSICHT Signalwort zur Kennzeichnung einer Gefährdung mit geringem Risiko, die zu einem Sach-schaden oder leichten bis mittelschweren Körperverletzungen führen kann, wenn sie nicht vermieden wird. WARNUNG Signalwort zur Kennzeichnung einer Gefährdung mit mittlerem Risiko, die möglicherweise Tod oder schwere Körperverletzungen zur Folge hat, wenn sie nicht vermieden wird. GEFAHR Signalwort zur Kennzeichnung einer Gefährdung mit hohem Risiko, die unmittelbar Tod oder schwere Körperverletzung zur Folge hat, wenn sie nicht vermieden wird. 4 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Warnung vor einer allgemeinen Gefahr Warnung vor explosionsgefährdeten Bereichen Netzstecker ziehen Warnung vor elektrischer Spannung Warnung vor heißer Oberfläche Atemschutz tragen Warnung vor dem Einatmen giftiger Gase Gesichtsschutz tragen Warnung vor ätzenden Flüssigkeiten Handschuhe tragen Das Gerät darf nur von Fachpersonal installiert werden, das mit den Sicherheitsanforderungen und den Risiken vertraut ist. Beachten Sie unbedingt die für den Einbauort relevanten Sicherheitsvorschriften und allgemein gültigen Regeln der Technik. Beugen Sie Störungen vor und vermeiden Sie dadurch Personen- und Sachschäden. Der für die Anlage Verantwortliche muss sicherstellen, dass: - Sicherheitshinweise und Betriebsanleitungen verfügbar sind und eingehalten werden, - Unfallverhütungsvorschriften der Berufsgenossenschaften beachtet werden; in Deutschland: Allgemeine Vorschriften” (VBG 1) und “Elektrische Anlagen und Betriebsmittel (VBG 4)”, - die zulässigen Daten und Einsatzbedingungen eingehalten werden, - Schutzeinrichtungen verwendet werden und vorgeschriebene Wartungsarbeiten durchgeführt werden, - bei der Entsorgung die gesetzlichen Regelungen beachtet werden. Wartung, Reparatur: - Reparaturen an den Betriebsmitteln dürfen nur von Bühler autorisiertem Personal ausgeführt werden. - Nur Umbau-, Wartungs- oder Montagearbeiten ausführen, die in dieser Bedienungs- und Installationsanleitung beschrieben sind. - Nur Original-Ersatzteile verwenden. Bei Durchführung von Wartungsarbeiten jeglicher Art müssen die relevanten Sicherheits- und Betriebsbestimmungen beachtet werden. ! GEFAHR Elektrische Spannung Gefahr eines elektrischen Schlages. Trennen Sie das Gerät vor Beginn der Wartungsarbeiten vom Netz. Sichern Sie das Gerät gegen unbeabsichtigtes Wiedereinschalten. Anschluss und Wartung dürfen nur von geschultem Fachpersonal vorgenommen werden. Achten Sie auf die korrekte Spannungsversorgung! BX550001, 10/2011 Art. Nr. 9031098 5 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 ! GEFAHR Giftige, ätzende Gase Messgas kann gesundheitsgefährdend sein. Sorgen Sie ggf. für eine sichere Ableitung des Gases. Stellen Sie vor Beginn der Wartungsarbeiten die Gaszufuhr ab und sichern Sie sie gegen unbeabsichtigtes Aufdrehen. Schützen Sie sich bei der Wartung vor giftigen / ätzenden Gasen. Tragen Sie die entsprechende Schutzausrüstung. ! GEFAHR Explosionsgefahr bei Verwendung in Explosionsgefährdeten Bereichen Das Betriebsmittel ist nicht für den Einsatz in explosionsgefährdeten Bereichen geeignet. Durch das Gerät dürfen keine zündfähigen oder explosiven Gasgemische geleitet werden. 3 Transport und Lagerungsvorschriften Die Betriebsmittel nur in der Originalverpackung oder einem geeigneten Ersatz transportieren. Bei längerer Nichtbenutzung sind sie gegen Feuchtigkeit und Wärme zu schützen. Die Betriebsmittel müssen in einem überdachten, trockenen, vibrations- und staubfreien Raum bei einer Temperatur von –20°C bis +50°C aufbewahrt werden. 4 Aufbauen und Anschließen Das Gerät darf nur von Fachpersonal installiert werden, das mit den Sicherheitsanforderungen und den Risiken vertraut ist. Beachten Sie unbedingt die für den Einbauort relevanten Sicherheitsvorschriften und allgemein gültigen Regeln der Technik. Beugen Sie Störungen vor und vermeiden Sie dadurch Personen- und Sachschäden. Wo immer möglich, sollte der O2-Sensor nach unten zeigend eingebaut werden. Dies muss immer dann erfolgen, wenn im Prozess ein sehr hoher Feuchteanteil vorhanden ist. Kommt es zur Kondensatbildung, kann der Einbau eines zusätzlichen Schutzrohres erforderlich sein. In trockenen Applikationen kann das Gerät auch waagerecht installiert werden. Der Montageort sollte jederzeit zugänglich und einsehbar Umgebungsbedingungen sollen die zulässigen Werte nicht überschreiten. sein. Die Bei Montage im Freien sollte der BA 1000 vor direkten Witterungseinwirkungen geschützt werden. Der O2-Sensor darf von Wasser oder Spritzwasser nicht erreicht werden. Die Montage in Feuchträumen ist unzulässig. 6 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 4.1 Elektrischer Anschluss WARNUNG Der Anschluss darf nur von geschultem Fachpersonal vorgenommen werden. Auf korrekte Spannungsversorgung achten. Örtliche Vorschriften beachten. HINWEIS ! Signalleitungen und Starkstromkabel nicht nebeneinander verlegen um die Gefahr von Störeinstrahlungen zu vermeiden. Ggf. abgeschirmtes Kabel verwenden. Beachten Sie zudem die nachfolgende Abbildung, um Fehler bei der elektrischen Verdrahtung zu vermeiden. Buchse J1: Stromversorgung Buchse J3: Messfühlerleitung grün -gelb* 2 PE Nr. 2* 3 GND weiß* GND grün* 0-10 V IMP 4 braun* 4-20 mA Nr. 1* 1 + 24 V GND 2 5 3 1 *Die Kabelzeichnungen gelten für das mitgelieferte Verbindungskabel Art.-Nr. 55012995 Netzteil BA 1000 N: 1 2 3 4 5 6 + - PE L1 N PE ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24V DC ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Netz 230V AC 48 – 62 Hz Digitalanzeige BA 1000 D 24: 1 2 3 4 + - + ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA 7 8 - + - PE ⏐ ⏐ ↓ ⏐ ⏐ ↑ ⏐ ⏐ ↑ 5 Abschirmung 6 BX550001, 10/2011 Art. Nr. 9031098 7 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Digitalanzeige BA 1000 D 230 7 8 9 10 11 - + - PE L1 N PE ⏐ ⏐ ↓ ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24V DC 2 3 4 + - + ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA 5 Abschirmung 6 1 ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Netz 230V AC 48 – 62 Hz 1 2 3 4 + - + - ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA ⏐ ⏐ ↓ 5 Abschirmung Digitalanzeige BA 1000 D 230 G 6 7 8 + - PE ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24 V DC ⎡ ⎢ ⎢ 9 \ \ 10 ⎤ ⎥ ⎥ 11 ⎡ ⎢ ⎢ 12 \ \ 13 Grenzwertkontakte ⎤ ⎥ ⎥ 14 15 16 17 L1 N PE ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Netz 230V AC 48 – 62 Hz Beim Anschluss des 4-20 mA- Ausgangs muss in den Digitalanzeigen die Brücke zwischen Klemme 3 und 4 entfernt werden. Beachten Sie die erforderlichen Leitungsquerschnitte in Abhängigkeit von der Kabellänge: Kabellänge Leitungsquerschnitt 30 m 0,25 mm2 60 m 0,5 mm2 100 m 0,75 mm2 Weiterhin ist folgender Einschaltstrom zu beachten. 8 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 A Einschaltstrom 4,4 2,6 0,6 0 15ms 70 ms 4.2 Einschraubverschraubung Es stehen 2 Einschraubverschraubungen für den Einbau des O2 Sensors zur Auswahl • 1/2“ NPT Einschraubverschraubung mit PTFE Klemmringen zur stufenlosen Längeneinstellung des O2 Sensors Artikelnummer 55012993 • 1/2“ NPT Einschraubverschraubung mit Edelstahl Klemmringen Artikelnummer 55012994 Bei dieser Ausführung ist nach dem Festziehen der Mutter keine nachträgliche Längeneinstellung des O2 Sensors möglich. (Der Schneidring wird im Sondenrohr eingeschnitten.) ∅12 NPT - 1/2" Montage BX550001, 10/2011 Art. Nr. 9031098 9 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 4.3 Einstellung der Grenzwertkontakte beim BA 1000 D 230 G Grau hinterlegte Tasten dauernd gedrückt halten. Im Anzeigemodus haben die Tasten folgende Funktionen: GW1 Anzeige Schaltausgang 1 GW2 Anzeige Schaltausgang 2 P Anzeige Geräteversion < Anzeige Minimalwert > Anzeige Maximalwert < + P lösche Minimalwert > + P lösche Maximalwert P +2x GW1 Änderungsmodus Schaltausgang 1 P +2x GW2 Änderungsmodus Schaltausgang 2 P + GW1 +2x GW2 Änderungsmodus Grundeinstellungen Tastenfunktionen im Änderungsmodus GW2 blättert vorwärts, zum nächsten Einstellpunkt GW1 blättert rückwärts, zum vorherigen Einstellpunkt < wählt die zu ändernde Stelle ( blinkend ) an > zählt die blinkenden Ziffern hoch P übernimmt Einstellungen, Ende Änderungsmodus Erfolgt zwei Minuten lang keine Eingabe, so schaltet das Gerät ohne Übernahme der Änderungen zurück in den Anzeigemodus. Änderungsmodus Schaltausgänge P +2x GW1 Änderungsmodus Schaltausgang 1 blättern GW2 GW1 P + GW1 Anzeige Einstellpunkt Bereich S1. S S1. H S1. An S1. Ab Schaltpunkt Schalthysterese Abzugsverzögerung ( in s ) Abfallverzögerung ( in s ) -19999...+19999 1...19999 Digit 0...999,9s 0...999,9s +2x GW2 Änderungsmodus Grundeinstellungen Einstellpunkte siehe oben 10 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5 Betrieb und Wartung 5.1 Warnhinweise Das Gerät darf nur von Fachpersonal installiert Sicherheitsanforderungen und den Risiken vertraut ist. und gewartet werden, das mit den - Das Gerät darf nicht außerhalb seiner Spezifikationen betrieben werden. - Reparaturen an den Betriebsmitteln dürfen nur von Bühler autorisiertem Personal ausgeführt werden. - Führen Sie nur Umbau-, Wartungs- oder Montagearbeiten aus, die in dieser Bedienungs- und Installationsanleitung beschrieben sind. - Verwenden Sie nur Original-Ersatzteile. - Beachten Sie bei der Durchführung von Wartungsarbeiten jeglicher Art die relevanten Sicherheits- und Betriebsbestimmungen. GEFAHR Elektrische Spannung Gefahr eines elektrischen Schlages. Trennen Sie das Gerät bei allen Wartungsarbeiten vom Netz. Sichern Sie das Gerät gegen unbeabsichtigtes Wiedereinschalten. Der Anschluss darf nur von geschultem Fachpersonal vorgenommen werden. Achten Sie auf die korrekte Spannungsversorgung! ! VORSICHT Spannungsverlust Beschädigung des Gerätes durch fehlende Versorgungsspannung Der BA 1000 muss im eingebauten Zustand immer mit Spannung versorgt werden, um den Sensor auf Betriebstemperatur zu halten. Dies ist erforderlich, damit es am Sensor auf keinen Fall zu Kondensatbildung kommt. 5.2 Inbetriebnahme Bei Einsatz in Kompostmieten siehe auch Kapitel 5.4 Vergewissern Sie sich vor der Inbetriebnahme, ob der Prozess unter Normalbedingungen läuft, alle Installationshinweise beachtet wurden und die korrekte Spannungsversorgung vorliegt. Überprüfen Sie weiterhin, ob alle Verbindungen korrekt ausgeführt sind. Lediglich der Deckel am O2Sensor kann geöffnet bleiben, damit die Grundeinstellung überprüft bzw. vorgenommen werden kann. BX550001, 10/2011 Art. Nr. 9031098 11 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5.2.1 Grundeinstellung An jedem BA 1000 wird vor Auslieferung ab Werk die Grundeinstellung vorgenommen. Diese kann vor Ort wie folgt überprüft werden: ¾ Schließen Sie an die Buchse J3 ein Amperemeter oder eine Kalibriereinheit BA 1000 KA an. ¾ Ziehen Sie den Sensor aus dem Prozess und halten Sie ihn für einige Minuten in die Umgebungsluft. Die Kalibriereinheit sollte bei Normalbedingungen (1013 mbar / 20°C) 20,9 bzw. 21 Vol% O2 anzeigen, das Amperemeter 17,44 mA. Dabei wird vorausgesetzt, dass die Umgebungsluft 20,9 Vol% O2 hat. Wird die Prüfung unter Umgebungsbedingungen vorgenommen, in denen der Normal O2-Gehalt zweifelhaft ist, muss ggf. Prüfgas verwendet werden. Die Sauerstoffanzeige ist abhängig von den Umgebungsbedingungen (Luftdruck, Temperatur). Bei der Überprüfung der Grundeinstellung nach längerem Betrieb des Analysators kann es erforderlich sein, dass dieser erst längere Zeit an Umgebungsluft betrieben wird, bevor die Grundeinstellung wieder erreicht wird. Dies hängt damit zusammen, dass aus dem Prozess stammende Gaskomponenten zunächst aus der Messzelle ausdiffundieren müssen. 5.2.2 Kalibrierung Der Endwert kann mit dem Span- Potentiometer eingestellt werden. Hierzu muss der Gehäusedeckel am O2 Sensor abgenommen werden. Sicherung/ Fuse Endwert/ Span A000106X Sicherung/ Fuse Endwert/ Span Abb.1 Innenansicht Standardgehäuse (links) und IP 66 – Gehäuse (rechts) ! VORSICHT Die Potentiometer Uref und Zero dürfen nicht verstellt werden! 12 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 Das Potentiometer Span dient zum Abgleich der Sauerstoffkonzentration. 20,9 Vol.-% O2 = 17,44 mA = 8,4V (bei 1013mbar/20°C) Span Zero Uref 5.3 Wartung Der BA 1000 arbeitet wartungsfrei. Je nach Anwendung empfiehlt sich von Zeit zu Zeit die Überprüfung der Grundeinstellung. Dabei ist zu beachten, dass die Druckverhältnisse innerhalb des Prozesses und in der Umgebungsluft von einander abweichen können. Dies führt zu Abweichungen in den Ausgabewerten. Um die Beeinflussung des Sensors der Messzelle durch Kondensat zu verhindern, empfehlen wir den Sensor aus dem Prozess zu ziehen. ! WARNUNG Heiße Oberfläche Verbrennungsgefahr bei Berührung der Sondenspitze Die Sondenspitze ist heiß. Berühren Sie die Sondenspitze nicht und tragen Sie Schutzhandschuhe. Trennen Sie ihn danach vom Netz, wenn Sie sichergestellt haben, dass kein Kondensat in die Messzelle gelangen kann. 5.3.1 Auswechseln der Schmelzsicherung Die Sicherung befindet sich im Gehäuse des O2-Sensors (siehe Abb. 1). ¾ Sensor aus dem Prozess ziehen. ¾ Sicherstellen, dass kein Kondensat in die Messzelle eindringen kann. ¾ Gerät vom Netz trennen und gegen wiedereinschalten sichern und Gehäuse öffnen. ¾ Schraubkappe von der Sicherung abnehmen. ¾ Schmelzsicherung 0,8 A träge ersetzen. ¾ Schraubkappe aufsetzen und wieder anziehen, Gehäusedeckel schließen, Gerät wieder ans Netz anschließen. BX550001, 10/2011 Art. Nr. 9031098 13 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5.4 Besonderheiten des BA 1000 S IP 66 zum Einsatz in Kompostmieten - Der Analysator darf nur in Verbindung mit einer Bodenlanze zur Überwachung von Kompostmieten eingesetzt werden. - Die Kalibrierung des Gerätes darf nur in trockener Umgebung durchgeführt werden, um ein Eindringen von Feuchtigkeit in die Elektronik zu vermeiden. - Sollte dies offensichtlich nicht der Fall sein und es zu starken Beschädigungen der Elektronik kommen verfällt der Garantieanspruch. ! HINWEIS Die Messzelle, einschließlich der Heizung, ist ein Verschleißteil und von der Gewährleistung ausgenommen. Ansonsten gelten unsere allgemeinen Geschäftsbedingungen. - Die Kalibrierung verläuft wie unter Punkt 4.1.2 beschrieben. - Das Elektronikgehäuse ist nach der Kalibrierung wieder absolut dicht zu verschließen. (Ein Dichtungswechsel am Elektronikgehäuse ist nach 4-5-maligem Kalibrieren zu empfehlen) - Sollte Feuchtigkeit in die Membran des Sensors dringen kann dieser nach Abtrocknen an der Luft wiederverwendet werden. - Eine Reinigung der Sonde mit einem Dampfstrahler zerstört das Gerät und ist nicht gestattet. - Hohe Konzentrationen an Schwermetallen und Schwefelverbindungen, sowie ein Ammoniakgehalt von > 2000 ppm beeinflussen die Lebensdauer der Messzelle. - Während des Betriebes in der Kompostmiete, darf das Gerät nicht von der Spannungsquelle abgeschaltet werden. (ÆAbkühlung der Heizung hat evtl. Kondensateinbrüche zur Folge.) 6 Instandsetzung und Entsorgung Sollte ein Fehler beim Betrieb auftreten, muss das Gerät durch den Hersteller überprüft werden. Sollten Sie Fragen haben, wenden Sie sich bitte an unseren Service Tel.: +49-(0)2102-498955 oder Ihre zuständige Vertretung. Bitte senden Sie das Gerät in geeigneter Verpackung an: Bühler Technologies GmbH - Reparatur/Service Harkortstraße 29 40880 Ratingen Deutschland Bringen Sie zusätzlich die Dekontaminierungserklärung ausgefüllt und unterschrieben an der Verpackung an. Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht möglich! Das Formular kann per E-Mail angefordert werden: service@buehler-technologies.com. 6.1 Entsorgung Bei der Entsorgung sind die gesetzlichen und Normenregelungen im Anwenderland zu beachten. 14 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 7 Anhang 7.1 Ersatzteile und Zubehör Art. Nr. Bezeichnung 5501599 Netzteil BA 1000 N, 115/ 230 V, 50/ 60 Hz, 24 V DC 5501699 Digitalanzeige 3 ½ stellig, BA 1000 D24, 24 V DC 5501799 Digitalanzeige 3 ½ stellig, incl. Netzteil, BA 1000 D230, 24 V DC 5501899 Digitalanzeige 4 ½ stellig, incl. Netzteil, BA 1000 D230G, 24 V DC 55012992 Kalibrieranzeige BA 1000 KA 55012993 Einschraubverschraubung ½“ NPT/ PTFE 55012994 Einschraubverschraubung ½“ NPT/ SS 9146100094 Stecker (Versorgung) J1-09-5106-15-03 9146100095 Stecker (Signalausgang) J3-09-5117-15-05 55013991 Sonde 380 mm 55014991 Sonde 780 mm 5501299 Elektronik Standardsonde 5502399 Bodensonde zum Einsatz in Kompostmieten 5502009953 Ersatzsonde 220 mm 550200995110 Elektronik (Kompostsonde) IP 66 7.2 Gewährleistung Die Messzelle, einschließlich der Heizung, ist ein Verschleißteil und von der Gewährleistung ausgenommen! Ansonsten gelten unsere allgemeinen Geschäftsbedingungen. 7.3 Beigefügte Dokumente - Datenblatt BA 1000. DD/DE/DA 550001 - Konformitätserklärung: KX 550007 - Dekontaminierungserklärung BX550001, 10/2011 Art. Nr. 9031098 15 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 1 Introduction The BA 1000 is for analysing the proportion of oxygen in gaseous mixtures. The unit may only be operated when it is in perfect condition and the operating instructions are followed. It is not suitable for use in ignitable gas mixtures or in surroundings endangered by explosion. Please take note of the information on the data sheets with regard to specific purpose and material combinations, as well as pressure and temperature limits. The BA 1000 S IP 66 is designed for monitoring oxygen in the decomposition during the rotting process. The probe is equipped with a damp-steady diaphragm as well as with IP 66-protected electronics. The probe length is 220 mm. For additional description of the BA 1000 S IP 66 see chapter 5.4. 2 Important advice Please check before installation of the device that the technical data matches the application parameters. Also, check that the delivery is complete. Operation of the device is only valid if - the product is used under the conditions described in the installation- and operation instruction, the intended application according to the type plate and the intended use, - the performance limits given in the datasheets and in the installation- and operation instruction are obeyed, - monitoring devices and safety devices are installed properly, - service and repair is carried out by Bühler Technologies GmbH, unless described in this manual, - only original spare parts are used. This manual is part of the equipment. The manufacturer keeps the right to modify specifications without advanced notice. Keep this manual for later use. Definitions for warnings: NOTE Signal word for important information to the product. CAUTION Signal word for a hazardous situation with low risk, resulting in damaged to the device or the property or minor or medium injuries if not avoided. WARNING Signal word for a hazardous situation with medium risk, possibly resulting in severe injuries or death if not avoided. DANGER Signal word for an imminent danger with high risk, resulting in severe injuries or death if not avoided. 16 Warning against hazardous situation Warning against possible explosive atmospheres disconnect from mains Warning against electrical voltage Warning against hot surface wear respirator Warning against respiration of toxic gases wear face protection Warning against acid and corrosive substances wear gloves BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 3 Transport and storing regulations The equipment should be only transported in the original case or in appropriate packing. Protect the equipment against heat and humidity. The level switch must be stored in roofed, dry, vibration- und dust free room. Temperature should be between –20°C and +50°C (-4°F and 122°F). 4 Installation and connection Take all necessary precautions and follow all safety regulations where you are installing the unit. The installation and connection may only be done by authorized members of staff. Check the power supply before connection! Wherever possible, the O2 sensor should be installed pointing down. This must always be done when a high proportion of moisture is in the process. If condensates should form, the installation of an additional protective pipe can be necessary. In dry applications, the unit can also be installed horizontally. The place of mounting should be accessible and visible at all times. The surroundings should be suitable. If mounted outdoors, the BA 1000 should be protected against the direct effects of weather. The O2 sensor must not be exposed to water or water spray. Mounting in damp rooms is not permissible. 4.1 Electrical connection WARNING The device must be installed by trained staff only. Regard the correct mains voltage as given on the type plate. NOTE ! To avoid the danger of spurious irradiation, do not lay signal lines and highvoltage cables next to one another. If appropriate, use shielded cables. Please note also the following illustration to avoid errors in wiring. Jack J1: Power supply green -yellow* 2 PE Nr. 2* 3 GND Jack J3: Sensor line green* 0-10 V IMP Nr. 1* 1 + 24 V white* brown* GND 4-20 mA 4 GND 2 5 1 BX550001, 10/2011 3 Art. Nr. 9031098 17 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 * The cable drawings refer to the supplied connection cable, part no. 55012995 BA 1000 N power pack: 1 2 3 4 5 6 + - PE L1 N PE ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24V DC ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Mains 230V AC 48 – 62 Hz BA 1000 D 24 digital display: 7 8 - + - PE ⏐ ⏐ ↓ ⏐ ⏐ ↑ ⏐ ⏐ ↑ 6 7 8 9 10 11 - PE L1 N PE 2 3 4 + - + ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA 5 shielding 6 1 BA 1000 D 230 digital display: 18 2 3 4 + - + - + ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA ⏐ ⏐ ↓ ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24V DC ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Mains 230V AC 48 – 62 Hz BX550001, 10/2011 Art. Nr. 9031098 5 Shielding 1 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 1 2 3 4 + - + - ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↓ 4 – 20 mA ⏐ ⏐ ↓ 5 Shielding BA 1000 D 230 G digital display: ⎡ ⎢ ⎢ 9 6 7 8 + - PE \ \ 10 ⏐ ⏐ ⏐ ⏐ ↓ ↓ 24 V DC ⎤ ⎥ ⎥ 11 ⎡ ⎢ ⎢ 12 \ \ 13 Limit contacts ⎤ ⎥ ⎥ 14 15 16 17 L1 N PE ⏐ ⏐ ⏐ ⏐ ⏐ ⏐ ↑ ↑ ↑ Mains 230V AC 48 – 62 Hz When the 4-20 mA- output is connected, the bridge between terminals 3 and 4 in the digital displays must be removed. Please note the required wire diameters depending on the cable length: Cable length 30 m 60 m 100 m Cross-section (approx. 98.5 ft) 0.25 mm2 (AWG 23) (approx. 197 ft) 0.5 mm 2 (AWG 21) 0.75 mm 2 (AWG 19) (approx. 328 ft) In addition, note the following starting current. A starting current 4,4 2,6 0,6 0 15ms 70 ms BX550001, 10/2011 Art. Nr. 9031098 19 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 4.2 Screw-in threaded joint There are two screw-in threaded joints to choose from for the installation of the sensor • 1/2“ NPT screw-in threaded joint with PTFE clamp collars for gradual adjustment of the length of the O2 sensor; part number 55012993 • 1/2“ NPT screw-in threaded joint with special steel clamp collars; part number 55012994 This model does not allow the length to be adjusted after the nut has been tightened. (The cutting ring is cut into the tube of the probe) Assembly NPT - 1/2" ∅12 20 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 4.3 Adjustment of the limit contacts of the BA 1000 D 230 G Press the gray keys and hold them down. In display mode, the keys have the following functions: GW1 Switch output display 1 GW2 Switch output display 2 P Unit version display < Minimum value display > Maximum value display < + P Delete minimum value > + P Delete maximum value P +2x GW1 Modification mode for switch output 1 P +2x GW2 Modification mode for switch output 2 P + GW1 +2x GW2 Modification mode basic settings Key functions in modification mode GW2 scrolls forward to next index point GW1 scrolls back to previous index point < selects the place to be modified ( blinks ) > counts up the blinking numbers P takes over settings, end modification mode If nothing is entered for two minutes, the unit will switch back to display mode without taking over the modifications. Display mode switch outputs P +2x GW1 scroll GW2 GW1 P +2x Modification mode for switch output 1 Display Index point Range S1. S S1. H S1. An S1. Ab switching point switching hysteresis discharge delay ( in s ) drop-out delay ( in s ) -19999...+19999 1...19999 Digit 0...999,9s 0...999,9s GW2 Modification mode for switch output 2 Index points see above BX550001, 10/2011 Art. Nr. 9031098 21 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5 Operation and maintenance 5.1 Indication of risk Installation and maintenance of the device shall be performed by trained staff only, familiar with the safety requirements and risks. - The device must be operated within its specifications. All repairs must be carried out by Bühler authorised personnel only. Only perform modifications, servicing, or mounting described in this manual. Only use original spare parts. Regard all relevant safety regulations and internal operating instructions during maintenance. DANGER Electrical voltage Electrocution hazard. Before any manipulation on the device, disconnect the electrical equipment from mains power supply. Make sure that the electrical equipment cannot be reconnected during repair or maintenance. The wiring must be done by trained staff only. Regard the correct mains voltage. ! CAUTION Voltage drop Damage of the device due to voltage drop The BA 1000 must always be supplied with power when it is installed in order to keep the sensors at operating temperature. This is necessary to ensure that no condensate forms on the sensor. 5.2 Starting For use in compost windrows see also chapter 5.4 for special hints. Before starting, make sure that the process will run under normal conditions, and that all installation instructions have been observed and the correct voltage supply is available. Also, check that all connections have been correctly made. The cover on the O2-sensor alone can remain open so that the basic setting can be checked or set. 22 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5.2.1 Basic setting The basic setting has been set on every BA 1000 before it leaves the factory. This can be checked on site as follows: ¾ Hook up an ampere meter or BA 1000 KA calibration unit to the J3 socket. ¾ Pull the sensor out of the process and hold it in the air for a few minutes. The calibration unit should now display 20.9 or 21Vol% O2, the ampere meter 17.44 mA. (Normal conditions assumed: 1013 mbar / 20°C (14.69 psi / 68°F)). This implies that the ambient air contains 20.9Vol% O2. In certain cases, a calibration gas must be used if the O2-content of ambient air cannot be guaranteed. The oxygen value depends on ambient conditions (barometric pressure / temperature). When the basic setting is checked after the analyser has been in operation for a long period, it may be necessary first to operate it for some time in ambient air before the basic setting is reached again. This is related to the fact that the gas components from the process first have to diffuse out of the measuring cell. 5.2.2 Calibration The final value can be set with the span potentiometer. To do so, remove the case cover of the O2 sensor. Sicherung/ Fuse Endwert/ Span Sicherung/ Fuse Endwert/ Span A000106X Fig.1 Interior view of the Standard housing (left) and the IP 66 model (right) ! CAUTION The Uref and Zero potentiometers must not be adjusted! The span potentiometer is for balancing the oxygen concentration. Span Zero Uref 20.9 vol.- % O2 = 17.44 mA = 8.4V (normal conditions 1013 mbar / 20°C) BX550001, 10/2011 Art. Nr. 9031098 23 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 5.3 Maintenance The BA 1000 requires no maintenance. Depending on the application, a check of the basic setting is advisable from time to time. In doing so, note that the pressure conditions in the process and in the surrounding air can deviate from each other. This leads to deviations in the output values. ! WARNING Hot surface Burning hazard when touching the probe. The tip of the probe is hot. Do not touch the probe and wear protection gloves. In order to prevent condensate from affecting the sensor on the measuring cell, we recommend pulling the sensor out of the process. Thereafter, unplug it when you have made sure that condensate can get into the measuring cell. 5.3.1 Replacing the fuse ¾ Move the sensor out of the process. ¾ Make sure that no condensate can form inside the measuring cell. ¾ Disconnect the device from mains supply, make sure that it cannot be switched on unintentionally, and open the cover. ¾ Take screw-on cap off the fuse. ¾ • Replace 0.8 A slow-acting fuse. ¾ • Put screw-on cap back on and tighten it. ¾ Close the cover and reconnect the device to mains supply. 5.4 Additional hints for BA 1000 S IP66 for decomposition - The analyser may be used only in connection with a soil lance for the monitoring of the decomposition. - The calibration of the equipment should be done only in dry environment, in order to avoid a penetration of humidity into electronics. - In case of not following these instructions the electronic may be damaged and therefore you loose your warranty. ! NOTE The measuring cell, including the heating unit, is subject to wear and tear and not covered by the warranty. See as well the general warranty regulations. - The calibration runs as described in chapter 4.1.2. - The electronics housing should be closed after every calibration again very tight. (We recommend replacing the seal every 4-5 calibrations.) - Should humidity penetrate into the diaphragm of the sensor, it could be reused after drying with air. - Cleaning the probe using a steam jet destroys the equipment and is not permitted. - High concentrations of heavy metals and sulphur compounds, as well as an ammonia concentration > 2000 ppm will affect the life span of the measuring probe. - During the measuring process in the compost, the equipment may not be switched off from the power supply. (ÆCooling down of the heater could effect that condensate can get into the measuring cell.) 24 BX550001, 10/2011 Art. Nr. 9031098 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 6 Repair and disposal If the device shows irregularities, the manufacturer must check the device. If you need help or more information call +49(0)2102-498955 or your local agent. Please hold the data of the type plate ready. Please ship the device with suitable packing to Bühler Technologies GmbH - Service Harkortstraße 29 40880 Ratingen Germany In Addition, attach the filled in and signed Declaration of Decontamination status to the packing. Otherwise, your repair order cannot be processed! The form can be requested by e-mail to service@buehlertechnologies.com. 6.1 Disposal Regard the local regulations for disposal of electric and electronic equipment. BX550001, 10/2011 Art. Nr. 9031098 25 Bedienungs- und Installationsanleitung Installation- and Operation Instruction Zirkonium Sauerstoffanalysator BA 1000 Circonia oxygen analyzer BA 1000 7 Appendix 7.1 Spare parts and accessories Part No. Designation 5501599 BA 1000 N power pack, 115/ 230 V, 50/ 60 Hz, 24 V DC 5501699 Digital display 3 ½ places, BA 1000 D24, 24 V DC 5501799 Digital display 3 ½ places, including power pack, BA 1000 D230, 24 V DC 5501899 Digital display 4 ½ places, including power pack, BA 1000 D230G, 24 V DC 55012992 BA 1000 KA calibration display 55012993 Screw-in threaded joint ½“ NPT/ PTFE 55012994 Screw-in threaded joint ½“ NPT/ SS 9146100094 Plug (power supply) J1-09-5106-15-03 9146100095 Plug (signal output) J3-09-5117-15-05 55013991 Probe 380 mm 55014991 Probe 780 mm 5501299 Electronic standard probe 5502399 Probe for use in compost 5502009953 Probe 220 mm 550200995110 Electronic (compost probe) IP 66 7.2 Warranty The measuring cell, including the heating unit, is subject to wear and tear and not covered by the warranty! See as well the general warranty regulations. 7.3 Attached documents - Data sheet BA 1000: DD/DE/DA 550001 - Declaration of conformity: KX 550007 - Declaration of Contamination status 26 BX550001, 10/2011 Art. Nr. 9031098 Zirkonium-Sauerstoffanalysator BA 1000 Beschreibung Der BA 1000 wurde für den Einsatz als Insitu-Sauerstoffsensor entwickelt. Das Messsystem des Sensors ist selbstüberwachend und daher für die Kontrolle von Feuerungsanlagen bestens geeignet. Funktion der Sauerstoffsonde Der dynamische Sauerstoffsensor ermöglicht es, Sauerstoffmessungen ohne Referenzgas durchzuführen. Der Sensor besteht aus zwei identischen Zirkondioxidscheiben, welche einen Platinring abdecken. Es entsteht eine dichte Kammer (P2), in ihr befindet sich ein Gas mit unbekanntem Sauerstoff-Partialdruck. Eine Scheibe ist mit einer umkehrbaren Stromquelle verbunden, sie dient als elektrochemische Sauerstoffpumpe. Die andere Scheibe ermittelt den O2-Partialdruck über die erzeugte Nernst`sche Spannung. Sensor Glas / glass werden wieder Sauerstoffionen in die Kammer gepumpt. Der Partialdruck P2 steigt an bis er wieder eine bestimmte Spannung erreicht hat, jetzt ändert sich die Stromrichtung erneut. Dieser Vorgang wiederholt sich periodisch. Die Periodenzeit ist linear zum Sauerstoffpartialdruck. Dieses Prinzip ermöglicht es, den Sensor ständig zu überwachen; der Sensor ist "fehlersicher"! Die Kalibrierung der Sonde erfolgt an atmosphärischer Luft. Dabei sind keine zusätzlichen Kalibriergase erforderlich. Ein optionaler Vorfilter ermöglicht den Einsatz auch bei höherer Staubbelastung. Anwendungsgebiete: Industrielle Heizanlagen, Industrielle Verbrennungsanlagen, Industrielle Prozesssteuerungsanlagen, Bio-Technik, Landwirtschaft (Silo), Medizin. Eigenschaften GND § niedriger Energieverbrauch A000063X § temperaturunabhängig UN=Messspannung / measuring voltage § 4 - 20 mA Ausgangssignal § fehlersicher Stromquelle / current source § keine Nullpunktdrift Heizung / heater § hohe Messgenauigkeit § sehr lange Lebensdauer Die Stromquelle wird eingeschaltet. Die Kammer wird evakuiert, der Partialdruck P2 ändert sich linear mit der transportierten Ladungsmenge. Dadurch steigt an der anderen Scheibe die Spannung an. Wenn die Spannung einen bestimmten Wert erreicht hat, ändert die Stromquelle ihre Stromrichtung, es DD 55 0001 10/2011 Seite 1/3 ® § flexibel einsetzbar § keine Referenzgase notwendig § keine Kalibriergase notwendig Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 49 89-0 Fax: + 49 (0) 2102 / 49 89-20 Internet: www.buehler-technologies.com e-mail: analyse@buehler-technologies.com Technische Daten Sensor BA 1000 S 90 ca. 5 Minuten 0,1 - 25 Vol.% O2 4-20 mA +/- 2 % vom Messbereichsendwert von 0 °C bis + 450 °C bis 10 m/s 12 mm ca. 3 sec - 10 bis + 50 °C - 20 bis + 70 °C 24 V DC 650 mA 4,4 A max.100 m IP 54 85 x 90 x 65 mm ca. 1,1 Kg Aluminium Edelstahl rostfrei ø12 Aufheizzeit Messbereich Ausgang Genauigkeit Entnahmetemperatur Abgasgeschwindigkeit Sondenrohrdurchmesser Reaktionszeit Umgebungstemperatur Lagertemperatur Spannungsversorgung Strom Einschaltstrom Entfernung Sonde / Elektronik Schutzart Abmessung ( B x H x T ) Gewicht Werkstoff Gehäuse Sondenrohr A000062X A 71 L 65 Ansicht A 153 85 Ausgang Eingang Erdanschluss Bestellhinweise: Bezeichnung: Sensor BA 1000 S Entnahmelänge L = 220 mm Sensor BA 1000 S Entnahmelänge L = 380 mm Sensor BA 1000 S Entnahmelänge L = 780 mm Optionen Netzteil BA 1000 N für Wandaufbau Spannungsversorgung Schutzart Gewicht Artikel-Nr. 55 01 398 55 01 399 55 01 499 55 01 599 115 / 230V AC 48 - 62 Hz wahlweise IP 65 2,1 kg Digitalanzeige BA 1000 D 230 G für Wandaufbau 4 ½ stellig, inkl. Netzteil mit 2 Grenzwertkontakten Schaltfunktion min - max, Schaltpunkt, Hysterese, Anzug- und Abfallzeiten frei einstellbar Kontaktbelastbarkeit 250 V / 3 A Spannungsversorgung 115 / 230V AC 48 - 62 Hz wahlweise Schutzart IP 65 Gewicht 2,7 kg 55 01 899 Kalibrieranzeige BA 1000 KA zur schnellen Überprüfung der Kalibrierung vor Ort Abmessung Gewicht 55 01 2992 Zubehör : Einschraubverschraubung Einschraubverschraubung Verbindungskabel 5 m Vorfilter ohne Montageflansch Vorfilter incl. Montageflansch DD 55 0001 10/2011 Seite 2/3 54 x 100 x 40 mm (B x H x T) 0,12 kg 1/2“ NPT mit PTFE Klemmring 1/2“ NPT mit Edelstahl Klemmring ( andere Längen auf Anfrage ) 55 01 2993 55 01 2994 55 01 2995 55 01 29971 55 01 2997 Technische Änderungen vorbehalten DD 55 0001 10/2011 Seite 3/3 Zirkonia Oxygen Analyser BA 1000 Description The Buhler Model BA 1000 solid-state oxygen analyser has been developed for in-situ applications. The cell is selfcontrolling and therefore well- suited for applications in flue gas or similar matrices. Principle of operation The dynamic sensor measures oxygen without using a reference gas. The sensor is consists of two zirconium discs covering both sides of a platinum ring. An additional Al2O3 coating protects the sensor from environmental influence and increases it´s life expectancy. The measurement chamber (P2) is filled with a sample gas. One disc is connected with a reversible source of current. It is then used as an solid-state electronic oxygen pump. On the opposite disc the partial pressure of oxygen is determined by measuring the induced Nernst potential. potential has reached a certain threshold, the polarity is reversed. Oxygen ions are then pumped back into the chamber and oxygen concentration increases. After reaching a certain threshold, the polarity changes again. This process is repeated over and over. The time for one period is linearly proportional to the oxygen concentration in the sample gas. An optional pre-filter enables operation in gas streams with high dust concentrations. Fields of applications include: Furnaces, industrial heating facilities, industrial combustion facilities, farming (in silos), medical, biotechnology Advantages and benefits § Low energy consumption Sensor A000063X Glas / glass § Temperature independent GND UN=Messspannung / measuring voltage Stromquelle / current source Heizung / heater First, the oxygen ions are pumped out of the chamber. The change in electrical charge on the first disc changes in direct linear proportion to the oxygen concentration. This increases the electric potential at the opposite disc. When the electric DE 55 0001 10/2011 Page 1/3 ® § § § § § § § § Linear output signals 4 - 20 mA Error protected High measurement precision Independent of gas matrix Long life Variety of applications No reference gas No calibration gas Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 49 89-0 Fax: + 49 (0) 2102 / 49 89-20 Internet: www.buehler-technologies.com e-mail: analyse@buehler-technologies.com Technical Data - Sensor BA 1000 S 90 approx. 5 minutes 0.1 - 25 Vol.% O2 4-20 mA ± 2 % of full scale value 0 °C up to +450 °C up to 10 m/s 12 mm approx. 3 seconds -10 to +50 °C -20 to +70 °C 24 V DC 650 mA 4.4 A max.100 m IP 54 85 x 90 x 65 mm ca. 1.1 kg stainless steel aluminium painted ø12 Warm-up time Measurement range Output Accuracy Sample temperature Exhaust gas velocity Probe diameter Response time Operating ambient temperature Storage temperature Power supply Current Switch-on current Distance analyser/ control unit Protection class Dimensions ( W x H x D ) Weight Material Probe tube Head A000062X A 71 L 65 View A 153 85 Output Input Protection ground Please indicate with order: Description: Sensor BA 1000 S with probe length L = 220 mm Sensor BA 1000 S with probe length L = 380 mm Sensor BA 1000 S with probe length L = 780 mm Options Power supply BA 1000 N wall mounted Power supply Protection class Weight 4 ½ digit LED display BA 1000 D 230 G wall mounted With 2 alarms for min. and max. function Free programmable Relays Power supply Protection class Weight Calibration display BA 1000 KA Quick-check calibration unit Dimensions Weight Tools : Pipe fitting for probe mounting Pipe fitting for probe mounting Interconnecting cable 5 m Complete pre filter with mounting flange Pre filter without mounting flange DE 55 0001 10/2011 Page 2/3 Part-no. 55 01 398 55 01 399 55 01 499 55 01 599 115 / 230V AC 48 - 62 Hz alternatively IP 65 2.1 kg 55 01 899 250 V / 3 A 115 / 230V AC 48 - 62 Hz alternatively IP 65 2.7 kg 55 01 2992 54 x 100 x 40 mm (W x H x D) 0.12 kg 1/2“ NPT with PTFE locking ring 1/2“ NPT with stainless steel locking ring ( other lenght on request ) 55 01 2993 55 01 2994 55 01 2995 55 01 2997 55 01 29971 we reserve the right to amend specification DE 55 0001 10/2011 Page 3/3 Zirconia Oxygen Analyzer BA 1000 Description The Buhler Model BA 1000 solid-state oxygen analyzer has been developed for in-situ applications. The cell is selfcontrolling and therefore well- suited for applications in flue gas or similar matrices. A000063X Principle of operation The dynamic sensor measures oxygen without using a reference gas. The sensor is consists of two zirconium discs covering both sides of a platinum ring. An additional Al2O3 coating protects the sensor from environmental influence and increases it´s life expectancy. The measurement chamber (P2) is filled with a sample gas. One disc is connected with a reversible source of current. It is then used as an solid-state electronic oxygen pump. On the opposite disc the partial pressure of oxygen is determined by measuring the induced Nernst potential. First, the oxygen ions are pumped out of the chamber. The change in electrical charge on the first disc changes in direct linear proportion to the oxygen concentration. This increases the electric potential at the opposite disc. When the electric potential has reached a certain threshold, the polarity is DA 55 0001 10/2011 Page 1/3 reversed. Oxygen ions are then pumped back into the chamber and oxygen concentration increases. After reaching a certain threshold, the polarity changes again. This process is repeated over and over. The time for one period is linearly proportional to the oxygen concentration in the sample gas. An optional pre-filter enables operation in gas streams with high dust concentrations. Fields of applications include: Furnaces, industrial heating facilities, industrial combustion facilities, farming (in silos), medical, biotechnology Advantages and benefits § § § § § § § § § Low energy consumption Temperature independent Linear output signals 4 - 20 mA Error protected High measurement precision Independent of gas matrix Long life Variety of applications No reference gas § No calibration gas Buhler Technologies LLC 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546 Fax: 248.652.1598 Internet: www.buhlertech.com e-mail: sales@buhlertech.com 3.54” Warm-up time approx. 5 minutes Measurement range 0.1 - 25 Vol.% O2 Output 4-20 mA Accuracy +/- 2 % of full scale value Sample temperature 32 °F up to + 840 °F Exhaust gas velocity up to 32 ft/s Probe diameter 12 mm (0.47”) Response time approx. 3 seconds Operating ambient temperature 15 to 120 °F Storage temperature - 5 to + 160 °F Power supply 24 V DC Current 650 mA Switch on current 4.4 A Distance analyzer/control unit max. 325 ft. Protection class IP 54 Dimensions ( B x H x T ) 85 x 90 x 65 mm 3.3 x 3.5 x 2.6 in. Weight ca. 2.43 lb Material Probe tube stainless steel Head aluminum painted A000062X ø0.47” Technical Data - Sensor BA 1000 S A 2.80” L 2.56” View A 6.02” 3.35” Output Input Protection ground Please indicate with order: Description: Sensor BA 1000 S with probe length L = 220 mm (8.7 in.) Sensor BA 1000 S with probe length L = 380 mm (15.0 in.) Sensor BA 1000 S with probe length L = 780 mm (30.7 in.) Options Power supply BA 1000 N wall mounted Power supply Protection class Weight 4 ½ digit LED display BA 1000 D 230 G wall mounted With 2 alarms for min. and max. function Free programmable Relays Power supply Protection class Weight Calibration display BA 1000 KA Quick-check calibration unit Dimensions Weight Tools : Pipe fitting for probe mounting Pipe fitting for probe mounting Interconnecting cable 5 m Complete pre filter with mounting flange Pre filter without mounting flange DA 55 0001 10/2011 Page 2/3 Part-no. 55 01 398 55 01 399 55 01 499 55 01 599 115 / 230V AC 48 - 62 Hz alternatively IP 65 4.6 lb 55 01 899 250 V / 3 A 115 / 230V AC 48 - 62 Hz alternatively IP 65 6.0 lb 55 01 2992 54 x 100 x 40 mm (W x H x D) 0.26 lb 1/2“ NPT with PTFE locking ring 1/2“ NPT with stainless steel locking ring ( other length on request ) 55 01 2993 55 01 2994 55 01 2995 55 01 2997 55 01 29971 we reserve the right to amend specification Note: All dimensions in this diagram are given in mm (unless otherwise noted)! DA 55 0001 10/2011 Page 3/3 RMA - Dekontaminierungserklärung RMA - Decontamination Statement DE/EN Gültig ab / valid since: 2014/11/01 Revision / Revision 1 ersetzt Rev. / replaces Rev. 0 Um eine schnelle und reibungslose Bearbeitung Ihres Anliegens zu erreichen, füllen Sie bitte diesen Rücksendeschein aus. Eine genaue Fehlerbeschreibung ist für die Ursachenanalyse nötig und hilft bei der schnellen Bearbeitung des Vorgangs. Die Aussage „Defekt“ hilft bei der Fehlersuche leider nicht. Please complete this return form to ensure your claim is processed quickly and efficiently. An accurate description of the problem is necessary for cause analysis and will help processing the claim quickly. Unfortunately, stating “defective” will not help us troubleshoot the issue. Die RMA-Nummer bekommen Sie von Ihrem Ansprechpartner im Vertrieb oder Service. You may obtain the RMA number from your sales or service representative. Zu diesem Rücksendeschein gehört eine Dekontaminierungserklärung. Die gesetzlichen Vorschriften schreiben vor, dass Sie uns diese Dekontaminierungserklärung ausgefüllt und unterschrieben zurücksenden müssen. Bitte füllen Sie auch diese im Sinne der Gesundheit unserer Mitarbeiter vollständig aus. This return form includes a decontamination statement. The law requires you to submit this completed and signed decontamination statement to us. Please complete the entire form, also in the interest of our employees’ health. Bringen Sie den Rücksendeschein mit der Dekontaminierungserklärung bitte zusammen mit den Versandpapieren in einer Klarsichthülle außen an der Verpackung an. Ansonsten ist eine Bearbeitung Ihres Reparaturauftrages nicht möglich! Attach the return form including decontamination statement along with the shipping documentation to the outside of the package, inside a clear pouch. Otherwise we are unable to process your repair order! Angaben zum Absender: Sender information: Firma / Company Ansprechpartner / Contact person Anschrift / Address Abteilung / Department E-Mai / E-Mail: Tel. / Phone Fax / Fax: Artikelnummer / Item number Auftragsnummer / Order number Anzahl / Quantity Rücksendegrund / Return reason RMA-Nr. / RMA no. Reparatur / Repair Garantie / Warranty Zur Prüfung / For inspection Rückgabe / Return Vorgangsnummer des Kunden / Customer transaction number:: Fehlerbeschreibung / Description of the problem: Ort, Datum / Place, Date Seite Page 1/2 Unterschrift / Stempel / Signature / Stamp: Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 4989-0 Fax: + 49 (0) 2102 / 4989-20 e-mail: service@buehler-technologies.com Internet: www.buehler-technologies.com RMA - Dekontaminierungserklärung RMA - Decontamination Statement DE/EN Gültig ab / valid since: 2014/11/01 Revision / Revision 1 ersetzt Rev. / replaces Rev. 0 Bitte füllen Sie diese Dekontaminierungserklärung für jedes einzelne Gerät aus. Gerät / Device RMA-Nr / RMA no: Serien-Nr. / Serial no. [ ] Please complete this decontamination statement for each individual item Ich bestätige hiermit, dass das oben spezifizierte Gerät ordnungsgemäß gereinigt und dekontaminiert wurde und keinerlei Gefahren im Umgang mit dem Produkt bestehen. I herewith declare that the device as specified above has been properly cleaned and decontaminated and that there are no risks present when dealing with the device. Ansonsten ist die mögliche Gefährdung genauer zu beschreiben: In other cases, please describe the hazards in detail: Aggregatzustand (bitte ankreuzen): Aggregate state (please check): Flüssig / Liquid Fest / Solid Folgende Warnhinweise sind zu beachten (bitte ankreuzen): Pulvrig / Powdery Please note the following warnings (please check): Explosiv Explosive Giftig / Tödlich Toxic / lethal Entzündliche Stoffe Flammable substances Komprimierte Gase Compressed gasses Gesundheitsgefährdend Hazardous to health Gesundheitsschädlich Harmful to health Bitte legen Sie ein aktuelles Datenblatt des Gefahrenstoffes bei! Ort, Datum / Place, Date: Seite Page 2/2 Gasförmig / Gaseous Brandfördernd Oxidizing Umweltgefährdend Harmful to the environment Please include an updated data sheet of the hazardous substance! Unterschrift / Stempel Signature / Stamp: Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 4989-0 Fax: + 49 (0) 2102 / 4989-20 e-mail: service@buehler-technologies.com Internet: www.buehler-technologies.com