Endress + Hauser Operating Instructions Turbimax CUS52D Turbidity sensor
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
BA01275C/07/EN/01.13 71237021 Products Solutions Operating Instructions Turbimax CUS52D Turbidity sensor Services Document information Warnings The structure, signal words and safety colors of the signs comply with the specifications of ANSI Z535.6 ("Product safety information in product manuals, instructions and other collateral materials"). Safety message structure ! DANGER Causes (/consequences) Consequences if safety message is not heeded ‣ Corrective action ! WARNING Causes (/consequences) Consequences if safety message is not heeded ‣ Corrective action ! CAUTION Causes (/consequences) Consequences if safety message is not heeded ‣ corrective action NOTICE Cause/situation Consequences if safety message is not heeded ‣ Action/note Meaning This symbol alerts you to a dangerous situation. Failure to avoid the situation will result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid the situation can result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or more serious injuries. This symbol alerts you to situations that can result in damage to property and equipment. Icons Additional information, tips Permitted or recommended Forbidden or not recommended Endress+Hauser Turbimax CUS52D Table of contents 1 Basic safety instructions . . . . . . . . . . . . . 4 9 Accessories . . . . . . . . . . . . . . . . . . . . . . . 35 1.1 1.2 1.3 1.4 1.5 Requirements for personnel . . . . . . . . . . . . . . . . . . 4 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Occupational safety . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operational safety . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Product safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Incoming acceptance and product identification . . . . . . . . . . . . . . . . . . . . . . 6 9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8 Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Mounting material . . . . . . . . . . . . . . . . . . . . . . . . . 35 Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Compressed air cleaning . . . . . . . . . . . . . . . . . . . . 36 Ultrasonic cleaning . . . . . . . . . . . . . . . . . . . . . . . . . 36 Bubble trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Calibration set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2.1 2.2 2.3 2.4 Incoming acceptance . . . . . . . . . . . . . . . . . . . . . . . . 6 Product identification . . . . . . . . . . . . . . . . . . . . . . . . 6 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Certificates and approvals . . . . . . . . . . . . . . . . . . . . 6 10 Technical data . . . . . . . . . . . . . . . . . . . . 38 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . 7 10.1 10.2 10.3 10.4 10.5 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Performance characteristics . . . . . . . . . . . . . . . . . 39 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Mechanical construction . . . . . . . . . . . . . . . . . . . . 40 3.1 3.2 3.3 3.4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation instructions . . . . . . . . . . . . . . . . . . . . . . 9 Installation examples . . . . . . . . . . . . . . . . . . . . . . 12 Post-installation check . . . . . . . . . . . . . . . . . . . . . 18 4 Electrical connection . . . . . . . . . . . . . . . 19 4.1 4.2 Connecting to the transmitter . . . . . . . . . . . . . . . 19 Post-connection check . . . . . . . . . . . . . . . . . . . . . 19 5 Device description . . . . . . . . . . . . . . . . . 20 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Sensor design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Measuring principle . . . . . . . . . . . . . . . . . . . . . . . Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cyclic cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signal filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calkit CUS52 solid state reference . . . . . . . . . . . 6 Diagnostics and troubleshooting. . . . . 32 7 Maintenance . . . . . . . . . . . . . . . . . . . . . . 33 7.1 Cleaning the sensor . . . . . . . . . . . . . . . . . . . . . . . 33 8 Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 8.1 8.2 8.3 Spare parts kits . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Endress+Hauser Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 20 20 21 22 30 30 31 3 Basic safety instructions Turbimax CUS52D 1 Basic safety instructions 1.1 Requirements for personnel ‣ Installation, commissioning, operation and maintenance of the measuring system must ‣ ‣ ‣ ‣ only be carried out by specially trained technical personnel. The technical personnel must be authorized for the specified activities by the system operator. Electrical connection must only be carried out by a certified electrician. The technical personnel must have read and understood these Operating Instructions and must follow the instructions they contain. Faults at the measuring point may only be rectified by authorized and specially trained personnel. Repairs not described in the enclosed Operating Instructions may only be carried out at the manufacturer’s premises or by the Service Organization. 1.2 Designated use CUS52D is a sensor designed to measure turbidity in drinking water and process water applications. The sensor is particularly suited for use in the following applications: • Final turbidity measurement in the outlet of waterworks • Turbidity measurement in the inlet of waterworks • Turbidity measurement at all stages of the process • Turbidity measurement for filter monitoring and filter backwashing • Turbidity measurement in drinking water networks Any use other than that described here compromises the safety of persons and the entire measuring system and is, therefore, not permitted. The manufacturer is not liable for damage resulting from improper or non-designated use. 1.3 Occupational safety As the user, you are responsible for complying with the following safety conditions: • Explosion protection guidelines (only devices approved for use in explosion hazardous areas) • Installation instructions • Local prevailing standards and regulations Electromagnetic compatibility This device has been tested for electromagnetic compatibility in accordance with the applicable European standards for industrial applications. The electromagnetic compatibility indicated only applies to a device that has been connected in accordance with the instructions in these Operating Instructions. 1.4 Operational safety ‣ Before commissioning the entire measuring point, make sure all the connections are ‣ ‣ 4 correct. Ensure that electrical cables and hose connections are not damaged. Do not operate damaged products, and secure them against unintentional commissioning. Mark the damaged product as defective. If faults cannot be rectified, the products must be taken out of service and secured against unintentional commissioning. Endress+Hauser Turbimax CUS52D Basic safety instructions 1.5 Product safety The product is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. Relevant regulations and European standards have been observed. Endress+Hauser 5 Incoming acceptance and product identification 2 Incoming acceptance and product identification 2.1 Incoming acceptance Turbimax CUS52D • Make sure the packaging is not damaged. • Notify the supplier of any damage to the packaging. Keep the damaged packaging until the matter has been settled. • Make sure the contents are not damaged. • Notify the supplier of any damage to the delivery contents. Keep the damaged products until the matter has been settled. • Check the delivery to make sure nothing is missing. Compare it against the shipping documents and your order. • Pack the product for storage and transportation in such a way that it is reliably protected against impact and moisture. The original packaging offers the best protection. Furthermore, the permitted ambient conditions must also be observed (see "Technical data"). • If you have any questions, contact your supplier or your local sales center. 2.2 Product identification 2.2.1 Nameplate The nameplate contains the following information: • Manufacturer details • Order code • Extended order code • Serial number • Operating conditions • Safety information symbols Compare the order code on the nameplate with your order. 2.2.2 Identifying the product The order code and serial number of your device can be found in the following locations: • On the nameplate • In the shipping documents To discover what product version you have, enter the order code on the nameplate into the search screen at the following address: www.products.endress.com/order-ident 2.3 Scope of delivery The scope of delivery comprises: • 1 Turbimax CUS52D sensor in the version ordered • 1 Set of Operating Instructions BA01275C/07/EN If you have any questions, contact your supplier or your local sales center. 2.4 Certificates and approvals Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the 4 mark. 6 Endress+Hauser Turbimax CUS52D Installation 3 Installation 3.1 Dimensions a0022048 Fig. 1: Dimensions in mm (inch) Compressed air cleaning Consumption: 50 l/min (13.2 gal/min) Pressure: 1.5 to 2 bar (22 to 30 psi) Connection: 6/8 mm or 6.35 mm (¼") a0022011 Fig. 2: Endress+Hauser CUS52D with compressed air cleaning 7 Installation Turbimax CUS52D a0022911 Fig. 3: 8 Calkit CUS52 solid state reference, dimensions in mm (inch) Endress+Hauser Turbimax CUS52D Installation 3.2 Installation instructions 3.2.1 Measuring system A complete measuring system consists of: • Turbimax CUS52D turbidity sensor • Liquiline CM44x multichannel transmitter • Direct installation in a pipe connection (2" clamp) or • Assembly: – CUA252 flow assembly or – CUA262 flow assembly or – Flexdip CYA112 assembly and Flexdip CYH112 holder system or – Retractable assembly, e.g. Cleanfit CUA451 a0022017 Fig. 4: 1 2 3 Direct installation in a pipe connection (2" clamp) Liquiline CM44x multichannel transmitter Turbimax CUS52D turbidity sensor Flow direction a0022018 Fig. 5: 1 2 3 4 Endress+Hauser Measuring system with flow assembly CUA252 Liquiline CM44x multichannel transmitter Turbimax CUS52D turbidity sensor CUA252 flow assembly Flow direction 9 Installation Turbimax CUS52D a0022019 Fig. 6: 1 2 3 4 Measuring system with flow assembly CUA262 Liquiline CM44x multichannel transmitter Turbimax CUS52D turbidity sensor CUA262 flow assembly Flow direction a0022229 Fig. 7: 1 2 3 4 10 Measuring system with retractable assembly Turbimax CUS52D turbidity sensor Liquiline CM44x multichannel transmitter Cleanfit CUA451 retractable assembly Flow direction Endress+Hauser Turbimax CUS52D Installation a0022020 Fig. 8: 1 2 3 Measuring system with immersion assembly Liquiline CM44x multichannel transmitter Weather protection cover Flexdip CYH112 holder system 4 5 Flexdip CYA112 assembly Turbimax CUS52D turbidity sensor a0022023 Fig. 9: 1 2 3 Endress+Hauser Measuring system with immersion assembly on chain holder system Flexdip CYH112 holder system Liquiline CM44x multichannel transmitter Weather protection cover 4 5 Flexdip CYA112 assembly Turbimax CUS52D turbidity sensor 11 Installation Turbimax CUS52D 3.3 Installation examples 3.3.1 Installation options • with clamp connection • with Flowfit CUA252 flow assembly • with Flowfit CUA262 flow assembly • with Cleanfit CUA451 retractable assembly • with "E" or "S" flow assembly from CUS31 • with Flexdip CYA112 immersion assembly and Flexdip CYH112 holder system The installation angle is 90°. The arrow points in the direction of flow. The optical windows in the sensor must be aligned against the direction of flow. A weld-in adapter is available as an accessory for installation (see "Accessories" section). a0022032 Fig. 10: Installation with 2" clamp connection > 10 0 (3 .9 4) 60 ... 64 (2.36 ... 2.52) 36 (1.42) a0022844 Fig. 11: Pipe connection with weld-in adapter, dimensions in mm (inch) The installation angle is 90°. The arrow points in the direction of flow. The optical windows in the sensor must be aligned against the direction of flow. a0022034 Fig. 12: 12 Installation with flow assembly CUA252 Endress+Hauser Turbimax CUS52D Installation The installation angle is 90°. The arrow points in the direction of flow. The optical windows in the sensor must be aligned against the direction of flow. a0022281 Fig. 13: Installation with flow assembly CUA262 The installation angle is 90°. The arrow points in the direction of flow. The optical windows in the sensor must be aligned against the direction of flow. For manual insertion/retraction of the assembly the medium pressure may not exceed 2 bar (29 psi). a0022285 Fig. 14: Installation with retractable assembly CUA451 The installation angle is 90°. The alignment of the sensor depends on the medium. In the case of media with little outgassing and with a tendency to form deposits, the optical windows face downwards (as shown in the graphic). In the case of media with strong outgassing and with no tendency to form deposits, the optical windows face upwards. The installation marking on the sensor helps the user align the sensor. a0022687 Fig. 15: Installation in CUS31-S flow assembly 1 a0022852 Fig. 16: 1 Endress+Hauser Installation marking for sensor alignment in the CUS31-S flow assembly Installation marking 13 Installation Turbimax CUS52D The arrow points in the direction of flow. The installation angle is 0°. If you are using the sensor in open basins, the sensor must be installed in such a way that bubbles cannot accumulate on it. a0022033 Fig. 17: 14 Installation with immersion assembly Endress+Hauser Turbimax CUS52D Installation 3.3.2 Pipe installation 3 3 5 4 1 2 2 a0022045 Fig. 18: Orientation and positions • Install the sensor in places with uniform flow conditions. • The best installation location is in the ascending pipe (pos. 1). Installation is also possible in the horizontal pipe (pos. 5). • Do not install in places where air spaces or bubbles occur (pos. 3) or where sedimentation may occur (pos. 2). • Avoid installation in the down pipe (pos. 4). • Avoid fittings downstream from pressure reduction stages which may cause outgassing. Wall effects: Backscattering on the pipe wall may result in the distortion of measurement values in the case of turbidity values < 200 FNU. Assembly adjustment is recommended. Black plastic pipes with diameter > DN 60 exhibit hardly any wall effects (<0.05 FNU). For this reason, the use of black plastic pipes is recommended. Endress+Hauser 15 Installation Turbimax CUS52D Additional information on avoiding wall effects: a0022249 Fig. 19: Orientations for pipes and assemblies • Install the sensor in such a way that the light beam is not reflected (pos. 6). • Avoid sudden changes in cross-section (pos. 9). Changes in cross-section should be gradual and located as far away as possible from the sensor (pos. 10). • Do not install the sensor directly downstream from a bend (pos. 7). Instead position it as far away as possible from the bend (pos. 8). • When using reflective materials (e.g. stainless steel), the pipe diameter must be at least 100 mm (4"). An assembly adjustment onsite is recommended. • Pipes made of stainless steel with diameter >DN 300 exhibit hardly any wall effects. 16 Endress+Hauser Turbimax CUS52D Installation 3.3.3 Immersion operation a0022020 Fig. 20: 1 2 3 Measuring system with immersion assembly Flexdip CYH112 holder system Liquiline CM44x multichannel transmitter Weather protection cover 4 5 Flexdip CYA112 assembly Turbimax CUS52D turbidity sensor Weather protection cover This type of installation is particularly suitable for strong or turbulent flow (>0.5 m/s (1.6 ft/s)) in basins or channels. Endress+Hauser 17 Installation Turbimax CUS52D Compressed air cleaning a0022713 Fig. 21: Installation marks 1 to 3 a0022715 Fig. 22: Mounting position Mount the compressed air cleaning system as follows: 1. Fit the compressed air cleaning system on the sensor ( å 22). 2. Position the securing ring of the compressed air cleaning system between installation marks 2 and 3 ( å 21) 3. Using a 4 mm Allen key, tighten the securing screw of the compressed air cleaning system slightly so that the compressed air cleaning system can still be rotated. 4. Turn the compressed air cleaning system so that the slit on the black ring is on installation mark 1 ( å 21). This way the nozzle is offset by 20° when blowing air at the optical windows. 5. Tighten the securing screw. 6. Fit the compressed air hose on the hose connection. 3.4 Post-installation check ‣ Sensor and cable undamaged? ‣ Is the orientation correct? ‣ Is the sensor installed in an assembly and not suspended freely from a cable? 18 Endress+Hauser Turbimax CUS52D Electrical connection 4 ! Electrical connection WARNING The device is live! Incorrect connection may result in injury or death ‣ The electrical connection must only be established by an electrical technician. ‣ The electrical technician must have read and understood these Operating Instructions and must follow the instructions they contain. ‣ Prior to commencing the connection work, make sure no voltage is applied at any of the cables. 4.1 Connecting to the transmitter The sensor is connected to the Liquiline CM442 transmitter as follows: • With the M12 plug (version: fixed cable, M12 plug) or • With the fixed cable connected to the terminal strips (version: fixed cable, end sleeves): a0012460 Fig. 23: Sensor connection The maximum cable length is 100 m (328 ft). 4.2 Post-connection check Device condition and specifications Notes Is damage visible on the outside of the sensor, assembly, junction box or cable? Visual inspection Electrical connection Notes Does the transmitter supply voltage match the specifications on the nameplate? Are the installed cables strain-relieved and not twisted? Is the cable type route completely isolated at the mounting location? Power cables / signal cables Are the power supply and signal cables connected correctly? Use the transmitter wiring diagram Are the cable cores stripped sufficiently and installed correctly in the terminal? Check if seated correctly (pull gently) Are all the screw terminals firmly tightened? Tighten Are all the cable entries installed, firmly tightened and leak-tight? For lateral cable entries, make sure the cable loops downwards to ensure water Are all the cable entries mounted on the side or pointing downwards? can drain off. Endress+Hauser 19 Device description Turbimax CUS52D 5 Device description 5.1 Sensor design The sensor is suitable for all drinking water and process water applications. The sensor is designed as a 40 mm sensor that can be operated directly and completely in the process without the need for further sampling (in situ). All the necessary modules are contained in the sensor: • Power supply • Light sources • Detectors detect the measuring signals, digitize them and process them to form a measured value. • The sensor microcontroller is responsible for controlling the internal processes and transmitting the data. All the data - including the calibration data - are stored in the sensor. The sensor can thus be precalibrated and used at a measuring point, calibrated externally, or used for several measuring points with different calibrations. a0022012 Fig. 24: 1 2 5.2 Arrangement of light source and light receiver Light receiver Light source Measuring principle The sensor works using the 90° light scattering principle in accordance with ISO 7027 and meets all the requirements of this standard (no divergence and a maximum divergence of 1.5°). The ISO 7027 standard is obligatory for turbidity measurements in the drinking water sector. 90° ± 2.5° 20° - 30° a0022230 Fig. 25: Measurement in accordance with ISO 7027 Measurement is done using a wavelength of 860 nm. 20 Endress+Hauser Turbimax CUS52D Device description 5.3 Applications The formazin factory calibration is used as the basis for precalibrating additional applications and optimizing them for the different media characteristics. Application: water Recommended operational range Max. display range Factory calibration for formazin 0.000 to 4000 FNU 0.000 to 9999 FNU Application: Kaolin 0 to 600 mg/l 0 to 3 g/l Application: PSL 0 to 500 0 to 3000 Application: diatomite 0 to 2200 mg/l 0 to 10 g/l To adapt to a specific application, customer calibrations can be carried out with up to 6 points. Endress+Hauser 21 Device description Turbimax CUS52D 5.4 Calibration The sensor is precalibrated on leaving the factory. As such, it can be used in a wide range of applications without the need for additional calibration. In addition the sensor offers a variety of ways to adapt the measurement to the particular application: • Assembly adjustment (compensation of wall effects in pipes and assemblies) • Calibration or adjustment (1 to 6 points) • Enter a factor (multiply the measured values by a constant factor) • Enter an offset (add/subtract a constant value to/from the measured values) • Duplicate the factory calibration data records a0022718-en Fig. 26: Flowchart To use the "Offset", "Factor" or "Assembly adjustment" functions, a new data record must first be created using 1 to 6-point calibration or by duplicating a factory data record. 22 Endress+Hauser Turbimax CUS52D Device description 5.4.1 Assembly adjustment Both the optical design of the CUS52D sensor and the CUA252 and CUA262 flow assemblies are optimized to minimize measured errors caused by wall effects in assemblies or pipes (measured error in CUA252 < 0.02 FNU). Using the "Assembly adjustment" function, it is possible to automatically compensate for the remaining measured errors caused by wall effects. The programmed function is based on formazin measurements and therefore may require subsequent calibration to adjust the measurement to the corresponding application or medium. The following types of assembly adjustment are available: Adjustment Description PE 100 Adjustment to Flowfit CUA 252 flow assembly 1.4404 (AISI 316 L) Adjustment to CUA 262 flow assembly Standard customer adjustment Adjustment to any pipes / assemblies Specialist customer adjustment Adjustment only recommended for E+H Service staff • If the "PE100" and "1.4404/316L" assembly adjustment options are selected, no other parameters must be specified. • The "Standard customer adjustment" option requires the user to enter additional parameters (material, surface and internal diameter). 5.4.2 Calibration / adjustment The factory calibrations of the individual applications (Formazin, Kaolin, PSL, Diatomite) are each based on 20 calibration points. Apart from the uneditable factory calibrations, the sensor contains six additional data records for saving process calibrations or for adaptation to the corresponding measuring point (application). 5.4.3 Selecting the applications On the CM44x, select the appropriate application for your field of application during initial commissioning or calibration. Model name Application Unit Formazin Drinking water, process water FNU; NTU; TE/F; EBC; ASBG Kaolin Drinking water, filtratable substances, process water mg/l; g/l; ppm PSL The calibration standard commonly used in Japan for drinking water turbidity Diatomite Mineral-based solids (sand) (dough) mg/l; g/l; ppm 1 to 6 points can be calibrated for all applications. Endress+Hauser 23 Device description Turbimax CUS52D 5.4.4 Single-point and multipoint calibration • Before a calibration, rinse the system until all air pockets and fouling are removed. • You can edit both the actual values and the target values in the calibration table (right and left column) • You can also add additional pairs of calibration values without measuring in a medium. • Lines interpolate between the calibration points. • When factory calibration data records are duplicated, the value pair 1000/1000 is automatically generated to map the factory data record 1:1 to the duplicated record. If you perform a single-point or multipoint calibration after duplicating the data record, you must delete this value pair (1000/1000) from the calibration table. Single-point calibration Application example: The sensor measured value in an application deviates from the laboratory value. This is corrected by a single-point calibration. a0022722-en Fig. 27: 1 2 Example for single-point calibration Factory calibration Application calibration Proceed as follows: 1. Select a data record. 2. Set a calibration point in the medium or enter the target sample value (laboratory value). In our example ( å 27) these are the values 600 FNU (measured value) and 400 FNU (target sample value). The gain for the application calibration changes accordingly. 24 Measured value Target sample value 600 400 Endress+Hauser Turbimax CUS52D Device description Two-point calibration Application example: Deviations in the measured value must be compensated for at two different points in an application (e.g. maximum value and minimum value of the application). This aims to ensure a maximum level of accuracy between these two extremes. a0022723-en Fig. 28: 1 2 Example for two-point calibration Factory calibration Application calibration Proceed as follows: 1. Select a data record. 2. Set two different calibration points in the medium or enter the target sample values for your application range. In our example ( å 28) these are the values 300 FNU (measured value) and 400 FNU (target sample value) as well as 800 FNU / 600 FNU. The gain and offset for the application calibration change accordingly. Measured value Target sample value 300 400 800 600 The gain outside the selected operational range is determined by the adjacent operational range (gray line). The characteristic must increase monotonically. Endress+Hauser 25 Device description Turbimax CUS52D Three-point calibration a0022724-en Fig. 29: 1 2 Example for three-point calibration Factory calibration Application calibration Proceed as follows: 1. Select a data record. 2. Set three different calibration points in the medium or enter the measured values and target sample values for your application range. In our example ( å 29) these are 300 / 400, 600 / 500 and 800 / 800. The gain and offset for the application calibration change accordingly. Measured value Target sample value 300 400 600 500 800 800 The gain outside the selected operational range is determined by the adjacent operational range (gray line). The characteristic must increase monotonically. 26 Endress+Hauser Turbimax CUS52D Device description Four-point calibration a0022725-en Fig. 30: 1 2 Example for four-point calibration Factory calibration Application calibration Proceed as follows: 1. Select a data record. 2. Set four different calibration points in the medium or enter the measured values and target sample values for your application range. In our example ( å 30) these are 200 / 200, 300 / 400, 600 / 500 and 800 / 800. The gain and offset for the application calibration change accordingly. Measured value Target sample value 200 200 300 400 600 500 800 800 The gain outside the selected operational range is determined by the adjacent operational range (gray line). The characteristic must increase monotonically. Endress+Hauser 27 Device description Turbimax CUS52D Calibration example for filter monitoring Application example: If a threshold is exceeded, the measured value is set to a maximum value regardless of the actual turbidity. a0022719-en Fig. 31: Example for filter monitoring Values for example above ( å 31): 28 Measured value Target sample value 0 0 100 100 101 1000 1000 1001 Endress+Hauser Turbimax CUS52D Device description 5.4.5 Factor With the "Factor" function, the measured values are multiplied by a constant factor. The functionality corresponds to that of a single-point calibration. Example This type of adjustment can be selected if the measured values were compared to the laboratory values over an extended period and all the values are too low by a constant factor of 10%, for instance. The values are adjusted by entering the factor 1.1. Application calibration FNU 2000 1500 1000 500 500 1000 1500 2000 FNU Factory calibration a0022733-en Fig. 32: Example for factor To use the "Factor" function, a new data record must first be created using 1 to 6-point calibration or by duplicating a factory data record. 5.4.6 Offset With the "Offset" function, the measured values are offset by a constant amount (added or subtracted). Application calibration FNU 2000 1500 1000 500 500 1000 1500 2000 FNU Factory calibration a0022734-en Fig. 33: Example for offset To use the "Offset" function, a new data record must first be created using 1 to 6-point calibration or by duplicating a factory data record. Endress+Hauser 29 Device description Turbimax CUS52D 5.5 Cyclic cleaning Compressed air is most suitable for cyclic cleaning in open basins and channels. The optional cleaning unit is either ready-supplied or can be retrofitted, and is fitted on the sensor head. It operates at a rate of 50 l/min (13.2 US gal/min) The following settings are recommended for the cleaning unit: Type of fouling Cleaning interval Cleaning duration Severe fouling with rapid buildup 5 min 10 s Low degree of fouling 10 min 10 s The CYR52 ultrasonic cleaning system is suitable for cyclic cleaning in pipes and assemblies. The (retrofittable) cleaning unit can be mounted on the CUA252, CUA262 flow assemblies, the flow assembly of CUS31 or on any customer pipe. The following cleaning settings are recommended to prevent the ultrasonic transducer from overheating: Cleaning duration Cleaning interval 5.6 max. 5 seconds min. 5 minutes Signal filter Optical turbidity measurements have a low signal-to-noise ratio particularly in the low turbidity range. In addition, disturbance variables can occur as a result of air bubbles, fouling etc. However a high level of damping affects the sensitivity of the measured value required in applications. For this reason, the sensor is fitted with an internal signal filter function in order to adapt the measurement flexibly to different measuring requirements. The following filter settings are possible: 30 Measured value filter Description Weak Low filtering, high sensitivity, fast response time (2 sec.) to changes Normal (default) Medium filtering, 10 sec. response time Strong Strong filtering, low sensitivity, slow response to changes (25 sec.) Specialist This menu is designed for the Endress+Hauser Service Team. Endress+Hauser Turbimax CUS52D Device description 5.7 Calkit CUS52 solid state reference The function and accuracy of the CUS52D sensor can be checked with the Calkit CUS52 solid state references. During factory calibration, every solid state reference is aligned with a special CUS52D sensor and can only be used with this sensor. Therefore the solid state reference and the CUS52D sensor are married (permanently assigned) to one another. The following solid state references are available: • 5 FNU (NTU) • 20 FNU (NTU) • 50 FNU (NTU) The reference value indicated on the solid state reference is reproduced with an accuracy of ±10% when the sensor is operating correctly. Function check using Calkit CUS52 a0022914 Fig. 34: Fitting the solid state reference on the sensor Preparatory steps: 1. Clean the sensor (see the "Cleaning the sensor" section). 2. Fix the sensor in place (e.g. with a laboratory stand). 3. With the solid state reference turned slightly ( å 34, B), fit it gently on the sensor (C) and 4. then allow the solid state reference to slide into the final position (D). Function check: 1. Enable the factory calibration on the transmitter. 2. Read off the measured value at the transmitter (depending on the signal filter settings it can take 2 to 25 seconds until the correct measured value appears). 3. Compare the measured value with the reference value on the Calkit52. The sensor is working perfectly if the value deviates by less than 10%. If you activate a calibration data record other measured values will result. Therefore, always select the factory calibration (formazin) when checking the function with Calkit solid state references. Endress+Hauser 31 Diagnostics and troubleshooting Turbimax CUS52D 6 Diagnostics and troubleshooting You must take the entire measuring point into account when troubleshooting: • Transmitter • Electrical connections and cables • Assembly • Sensor The possible causes of error indicated in the table below primarily refer to the sensor. Problem Check Remedial measures Nothing displayed, no reaction from the sensor Power supplied to the transmitter? Sensor connected correctly? Buildup on optical windows? Connect the mains voltage Connect sensor correctly Clean sensor Display value too high or Buildup on optical windows? too low Sensor calibrated? Clean Calibrate Display value fluctuates a lot Select other mounting location Adjust the measured value filter Check mounting location. Please observe the troubleshooting instructions provided in the transmitter operating manual. Examine the transmitter if necessary. 32 Endress+Hauser Turbimax CUS52D Maintenance 7 Maintenance You have to perform maintenance tasks at regular intervals. We recommend setting the maintenance times in advance in an operations journal or log. The maintenance cycle primarily depends on the following: • The facility • The installation conditions • The medium being measured ! CAUTION Risk of injury due to acid or medium ‣ Switch off the cleaning unit before removing the sensor from the medium. 7.1 Cleaning the sensor Sensor fouling can affect the measurement results and even cause a malfunction. The sensor must be cleaned at regular intervals to ensure reliable measurement results. The frequency and intensity of the cleaning process depends on the medium. Clean the sensor: • As specified in the maintenance schedule • Before every calibration • Before returning the sensor for repair Type of fouling Cleaning measure Lime deposits Immerse the sensor in 1-5 % hydrochloric acid (for a few minutes). Dirt particles on the optical windows Use a cleaning cloth to clean the optical windows. You must rinse the sensor thoroughly with water after cleaning. Endress+Hauser 33 Repair Turbimax CUS52D 8 Repair 8.1 Spare parts kits Order number Description 71247510 Cable assembly, ferrules, 3 m cable length 71247510 Cable assembly, ferrules, 7 m cable length 71247510 Cable assembly, ferrules, 15 m cable length 71247510 Cable assembly, M12 plug, 3 m cable length 71247510 Cable assembly, M12 plug, 7 m cable length 71247510 Cable assembly, M12 plug, 15 m cable length Detailed information on the spare parts kits is available in the "Spare Part Finding Tool", which can be accessed on the Web at: www.products.endress.com/spareparts_consumables 8.2 Return The product must be returned if repairs or a factory calibration are required, or if the wrong product has been ordered or delivered. According to legal regulations Endress+Hauser, as an ISO-certified company, is required to follow certain procedures when handling returned products that are in contact with the medium. To ensure swift, safe and professional device returns: Visit our website to obtain information about the return procedure and basic conditions: www.services.endress.com/return-material 8.3 Disposal The device contains electronic components and must therefore be disposed of in accordance with regulations on the disposal of electronic waste. Please observe local regulations. 34 Endress+Hauser Turbimax CUS52D Accessories 9 Accessories 9.1 Assemblies Flowfit CUA252 flow assembly • For CUS52D • Order as per product structure (--> Online Configurator, www.products.endress.com/ cua252) • Technical Information TI01139C/07/EN Flowfit CUA262 flow assembly • For CUS52D • Order as per product structure (--> Online Configurator, www.products.endress.com/ cua262) • Technical Information TI01152C/07/EN Flexdip CYA112 wastewater assembly • Modular assembly system for sensors in open basins, channels and tanks • PVC and stainless steel version • Order as per product structure (--> Online Configurator, www.products.endress.com/ cya112) • Technical Information TI00432C/07/EN Cleanfit CUA451 retractable assembly • Manual retractable assembly made of stainless steel with ball valve shut-off for turbidity sensors • Order as per product structure (--> Online Configurator, www.products.endress.com/ cua451) • Technical Information TI00369C/07/EN 9.2 Mounting material Weld-in adapter for clamp connection DN 50 • Material: 1.4404 (AISI 316 L) • Wall thickness 1.5 mm • Order number: 71242201 36 (1.42) 30 (1.18) Ø 53 (2.09) Ø 64 (2.52) a0022838 Fig. 35: Endress+Hauser Dimensions in mm (inch) 35 Accessories Turbimax CUS52D 9.3 Holder Flexdip CYH112 holder system for Flexdip CYA112 water and wastewater assemblies • Modular holder system for sensors and assemblies in open basins, channels and tanks • The holder system can be secured in any way, be it on the floor, the cap stone, the wall or directly on a railing. • Stainless steel version • Order as per product structure (--> Online Configurator: www.products.endress.com/ cyh112) • Technical Information TI00430C/07/EN 9.4 Compressed air cleaning Compressed air cleaning for CUS52D • Connection: 6 mm • Materials: PE black • Order no.: 71242026 a0022052 Fig. 36: X Compressed air cleaning, dimensions in mm (inch) 6 mm hose nozzle Compressor • For compressed air cleaning • 230 V AC order no. 71072583 • 115 V AC order no. 71194623 9.5 Ultrasonic cleaning Ultrasonic cleaning system CYR52 • For attachment to assemblies and pipes • Order as per product structure (--> Online Configurator, www.products.endress.com/ cyr52) • Technical Information TI01153C/07/EN 36 Endress+Hauser Turbimax CUS52D Accessories 9.6 Bubble trap 1 2 3 12 (3/8") 12 (3/8") Bubble trap • For sensor CUS52D • Process pressure: up to 3 bar (43.5 psi) • Process temperature: 0 to 50 °C (32 to 122 °F) • Adapter to D 12 with connection for vent line (top connection on CUA252), is included in the delivery. • Orifice plates for the following volume flow rates: – < 60 l/h (15.8 gal/hr) – 60 to 100 l/h (15.8 to 26.4 gal/hr) – > 100 l/h (26.4 gal/hr) • The vent line is fitted with a PVC hose, hose check valve and a Luer lock adapter. • Order number, suitable for assembly CUA252: 71242170 • Order number, suitable for assembly S of CUS31: 71247364 254 (10.0) a0022631 Fig. 37: 1 2 3 9.7 Bubble trap, dimensions in mm (inch) Inlet for medium (without hose system) Outlet for bubbles (hose system is included in scope of supply) Outlet for medium (without hose system) Calibration set CUY52 calibration set • For CUS52D • Order as per product structure (--> Online Configurator, www.products.endress.com/ cuy52) • Technical Information TI01154C/07/EN 9.8 Transmitter Liquiline CM44x/CM44xR • Multichannel transmitter for connecting digital sensors with Memosens technology • Field device (CM44x) or DIN rail device (CM44xR) • Power supply 100 to 230 V AC, 24 V AC/DC • Universally extensible • Slot for SD card • Order as per product structure (--> Configurator on product page) • Technical Information TI00444C/07/EN (CM44x) or TI01112C/07/EN (CM44xR) Endress+Hauser 37 Technical data Turbimax CUS52D 10 Technical data 10.1 Input Measured variables Turbidity Temperature Measuring ranges CUS52D Turbidity Temperature 0.000 to 4000 FNU Display range up to 9999 FNU -20 to +85 °C (-4 to +185 °F) Application Formazin For measuring range up to 10 FNU, the sensor exhibits a detection limit (LOD) of 0.0015 FNU (measured in accordance with ISO 15839). 38 Endress+Hauser Turbimax CUS52D Technical data 10.2 Performance characteristics Measured error 2% ±0.01 FNU; reference: factory calibration Wavelength 860 nm Conformity Determining turbidity in accordance with ISO 7027 Factory calibration The sensor has been calibrated in the factory for "formazin" applications. Basis: internal 20-point characteristic curve Applications The formazin factory calibration is used as the basis for precalibrating additional applications and optimizing them for the different media characteristics. Application: water Recommended operating ranges Max. display range Factory calibration for formazin 0.000 to 4000 FNU 0.000 to 9999 FNU Application: Kaolin 0 to 600 mg/l 0 to 3 g/l Application: PSL 0 to 500 0 to 3000 Application: diatomite 0 to 2200 mg/l 0 to 10 g/l To adapt to a specific application, customer calibrations can be carried out with up to 6 points. Drift Detection limits Working on the basis of electronic controls, the sensor is largely free of drifts. Application Measuring range Detection limit Formazin 0 to 10 FNU (ISO 15839) 0.0015 FNU Response time >1 sec, adjustable Repeatability < 0.5 % of measured value (measuring range : 0 to 10 FNU) Endress+Hauser 39 Technical data Turbimax CUS52D 10.3 Environment Ambient temperature range -20 to 60 °C (-4 to 140 °F) Storage temperature -20 to 70 °C (-4 to 158 °F) Degree of protection IP 68 (test condition: 1.8 m (5.91 ft) water column over 20 days, 1 mol/l KCl) 10.4 Process Process temperature -20 to 85 °C (-4 to 185 °F) Process pressure 0.5 to 10 bar (7 to 145 psi) absolute Minimum flow No minimum flow necessary. For solids which have a tendency to form deposits, ensure that sufficient mixing is performed. 10.5 Mechanical construction Dimensions See "Installation conditions" Weight Sensor with 7 m cable With clamp Without clamp approx. 1.56 kg approx. 1.48 kg Materials Sensor Optical windows O-rings Process connections G1 and NPT ¾'' 2" clamp (depends on sensor version)/ DIN 32676 40 Stainless steel 1.4404 (AISI 316 L) Sapphire EPDM Endress+Hauser Turbimax CUS52D Endress+Hauser Technical data 41 Turbimax CUS52D Index A Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . 40 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 39 Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Assembly adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 B Bubble trap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cyclic cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 37 33 19 30 D Damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Designated use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 E Electrical technician . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . 4 F Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Factory calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Filter monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 H Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 I Immersion operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Incoming acceptance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Input Measured variables . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Measuring ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 M Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Measured error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Measured variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Measuring ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Minimum flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Mounting material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Multipoint calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 N Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 O Occupational safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Operational safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 P Performance characteristics Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Measured error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Pipe installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Post-connection check . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Post-installation check . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Process pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Process temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Product identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 R Requirements for personnel . . . . . . . . . . . . . . . . . . . . . . . . 4 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 S Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Selecting the applications . . . . . . . . . . . . . . . . . . . . . . . . . 23 Sensor design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Signal filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Single-point calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Solid state reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Spare parts kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Storage temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 T Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Transmitter connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 U Ultrasonic cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 42 Endress+Hauser Turbimax CUS52D W Wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Endress+Hauser 43 71237021 www.addresses.endress.com