Endress + Hauser Operating Instructions Condumax CLS15D/16D/21D Sensors with Memosens protocol
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
BA01147C/07/EN/03.16 71333350 Products Solutions Services Operating Instructions Condumax CLS15D/16D/21D Sensors with Memosens protocol For conductive measurement of conductivity in liquids 0 Table of contents Table of contents 1 Document information . . . . . . . . . 4 1.1 1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Basic safety instructions . . . . . . . 5 2.1 2.2 2.3 2.4 2.5 Requirements for personnel . . . . . . . . . . . Designated use . . . . . . . . . . . . . . . . . . . . . . Occupational safety . . . . . . . . . . . . . . . . . . Operational safety . . . . . . . . . . . . . . . . . . . Product safety . . . . . . . . . . . . . . . . . . . . . . . 3 Incoming acceptance and product identification . . . . . . . . . . 9 3.1 3.2 3.3 3.4 Incoming acceptance . . . . . . . . . . . . . . . . . 9 Product identification . . . . . . . . . . . . . . . . . 9 Scope of delivery . . . . . . . . . . . . . . . . . . . . 10 Certificates and approvals . . . . . . . . . . . . 11 5 5 5 6 6 4 Installation . . . . . . . . . . . . . . . . . . . . 12 4.1 4.2 Mounting the sensor . . . . . . . . . . . . . . . . 12 Post-installation check . . . . . . . . . . . . . . . 16 5 Electrical connection . . . . . . . . . . 16 5.1 5.2 5.3 5.4 Connection conditions . . . . . . . . . . . . . . . Connecting the sensor . . . . . . . . . . . . . . . Ensuring the degree of protection . . . . . Post-connection check . . . . . . . . . . . . . . . 6 Commissioning . . . . . . . . . . . . . . . . 20 7 Maintenance . . . . . . . . . . . . . . . . . . 20 17 19 19 19 8 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . 21 8.1 8.2 8.3 Sealing ring replacement and recalibration (CLS16D only) . . . . . . . . . . 21 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 9 Technical data . . . . . . . . . . . . . . . . . 23 10 EU Declaration of conformity . . . . . . . . . . . . . . . . . . . . . 29 10.1 ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga . . . . . . . 29 10.2 ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Endress+Hauser 3 Document information Condumax CLS15D/16D/21D 1 Document information 1.1 Warnings Structure of information LDANGER Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action LWARNING Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action LCAUTION Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action NOTICE Meaning This symbol alerts you to a dangerous situation. Failure to avoid the dangerous situation will result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid the dangerous situation can result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or more serious injuries. This symbol alerts you to situations which may result in damage to property. Cause/situation Consequences of non-compliance (if applicable) ‣ Action/note 1.2 Symbol Symbols Meaning Additional information, tips Permitted or recommended Not permitted or not recommended Reference to device documentation Reference to page Reference to graphic  4 Result of a step Endress+Hauser Condumax CLS15D/16D/21D 2 Basic safety instructions 2.1 Requirements for personnel Basic safety instructions • Installation, commissioning, operation and maintenance of the measuring system may be carried out only by specially trained technical personnel. • The technical personnel must be authorized by the plant operator to carry out the specified activities. • The electrical connection may be performed only by an electrical technician. • The technical personnel must have read and understood these Operating Instructions and must follow the instructions contained therein. • Measuring point faults may be repaired only by authorized and specially trained personnel. Repairs not described in the Operating Instructions provided may only be carried out directly by the manufacturer or by the service organization. 2.2 Designated use The conductivity sensors are designed for the conductive measurement of the conductivity of liquids. They are used in the following fields: Sensor Applications Hazardous areas Condumax CLS15D Measurements in pure and ultrapure water Approved for Ex zone 0 Condumax CLS16D Measurements in pure and ultrapure water with hygienic requirements Approved for Ex zone 0 Condumax CLS21D Measurements in media with medium or high conductivity Approved for Ex zone 0 Use of the device for any purpose other than that described, poses a threat to the safety of people and of the entire measuring system and is therefore not permitted. The manufacturer is not liable for damage caused by improper or non-designated use. 2.3 Occupational safety As the user, you are responsible for complying with the following safety conditions: • Installation guidelines • Local standards and regulations • Regulations for explosion protection Electromagnetic compatibility • The product has been tested for electromagnetic compatibility in accordance with the applicable European standards for industrial applications. • The electromagnetic compatibility indicated applies only to a product that has been connected in accordance with these Operating Instructions. Endress+Hauser 5 Basic safety instructions 2.4 Condumax CLS15D/16D/21D Operational safety 1. Before commissioning the entire measuring point, verify that all connections are correct. Ensure that electrical cables and hose connections are undamaged. 2. Do not operate damaged products, and safeguard them to ensure that they are not operated inadvertently. Label the damaged product as defective. 3. If faults cannot be rectified: Take the products out of operation and safeguard them to ensure that they are not operated inadvertently. 2.5 Product safety 2.5.1 State of the art The product is designed to meet state-of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate. The relevant regulations and European standards have been observed. 2.5.2 Electrical equipment in hazardous areas ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga • The Memosens inductive sensor-cable connection system is suitable for use in hazardous areas in accordance with EC type examination certificate BVS 04 ATEX E 121 X. The corresponding EC declaration of conformity is part of this document. • The certified conductivity sensors CLS15D/CLS16D/CLS21D may only be connected via the measuring cable CYK10-G/I*** to the certified intrinsically safe digital sensor output circuits of measuring device Liquiline M CM42-KE/F/G/I/J********** in accordance with EC type-examination certificate TÜV 13 ATEX 7459 X. • The electrical connection must be made according to the wiring diagram of the transmitter. • Metallic process connection parts must be mounted at the mounting location electrostatically conductive (< 1 MΩ). • The CLS15D-type sensors with non-metal process connections and the CLS21D-type sensors may only be employed for measurement in liquids with a minimum conductivity of 10 nS/cm. • The CLS15D-type sensors with non-metal process connections may not be operated under process conditions in which electrostatic charging of the sensor, and particularly of the electrically insulated outer electrode, is likely to occur. • Measuring cable CYK10-G/I*** and its terminal head must be protected against electrostatic charging if it is run through Zone 0. • The maximum permitted cable length is 100 m. • Ex versions of digital sensors with Memosens technology are indicated by an orange-red ring. • Full compliance with regulations for electrical systems in hazardous areas (e.g. EN/IEC 60079-14) is mandatory when using the devices and sensors. 6 Endress+Hauser Condumax CLS15D/16D/21D Basic safety instructions Temperature classes Name Type Medium temp. Ta for temperature class (Tn) Cat. Condumax CLS15D - A ** G -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +120 °C (T4) -20 °C ≤ Ta ≤ +70 °C (T6) II 1G Condumax CLS15D - B/L ** G -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +100 °C (T4) -20 °C ≤ Ta ≤ +50 °C (T6) II 1G Condumax CLS16D - ** ** G -5 °C ≤ Ta ≤ +135 °C (T3) -5 °C ≤ Ta ≤ +115 °C (T4) -5 °C ≤ Ta ≤ +65 °C (T6) II 1G Condumax CLS21D - * ** G -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +115 °C (T4) -20 °C ≤ Ta ≤ +65 °C (T6) II 1G If the specified medium temperatures are complied with, temperatures that are not permitted for the respective temperature class will not occur on the equipment. ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc • The Memosens inductive sensor-cable connection system is suitable for use in hazardous areas, Zone 2. The corresponding EU declaration of conformity is part of this document. • The certified conductivity sensors CLS15D / CLS16D / CLS21D may only be connected via the measuring cable CYK10-V*** to the certified intrinsically safe digital sensor output circuits of measuring device Liquiline M CM42-KV*********. • The electrical connection must be made according to the wiring diagram of the transmitter. • Metallic process connection parts must be mounted at the mounting location electrostatically conductive (< 1 MΩ). • The CLS15D-type sensors with non-metal process connections and the CLS21D-type sensors may only be employed for measurement in liquids with a minimum conductivity of 10 nS/cm. • The CLS15D-type sensors with non-metal process connections may not be operated under process conditions in which electrostatic charging of the sensor, particularly of the electrically insulated outer electrode, is likely to occur. • The maximum permitted cable length is 100 m. • Full compliance with regulations for electrical systems in hazardous areas (EN/IEC 60079-14) is mandatory when using the devices and sensors. Temperature classes Name Type Condumax CLS15D - A ** Condumax CLS15D - B/L ** Endress+Hauser Medium temp. Ta for temperature class (Tn) Cat. V -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +120 °C (T4) -20 °C ≤ Ta ≤ +70 °C (T6) II 3G V -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +100 °C (T4) -20 °C ≤ Ta ≤ +50 °C (T6) II 3G 7 Basic safety instructions Condumax CLS15D/16D/21D Name Type Condumax CLS16D - ** ** Condumax CLS21D - * ** Medium temp. Ta for temperature class (Tn) Cat. V -5 °C ≤ Ta ≤ +135 °C (T3) -5 °C ≤ Ta ≤ +115 °C (T4) -5 °C ≤ Ta ≤ +65 °C (T6) II 3G V -20 °C ≤ Ta ≤ +135 °C (T3) -20 °C ≤ Ta ≤ +115 °C (T4) -20 °C ≤ Ta ≤ +65 °C (T6) II 3G If the specified medium temperatures are complied with, temperatures that are not permitted for the respective temperature class will not occur on the equipment. FM/CSA IS/NI Cl.1 Div.1&2 Gr. A-D Observe the documentation and the control drawings of the transmitter. 8 Endress+Hauser Condumax CLS15D/16D/21D Incoming acceptance and product identification 3 Incoming acceptance and product identification 3.1 Incoming acceptance 1. Verify that the packaging is undamaged.  Notify your supplier of any damage to the packaging. Keep the damaged packaging until the matter has been settled. 2. Verify that the contents are undamaged.  Notify your supplier of any damage to the delivery contents. Keep the damaged products until the matter has been settled. 3. Check the delivery for completeness.  Check it against the delivery papers and your order. 4. Pack the product for storage and transportation in such a way that it is protected against impact and moisture.  The original packaging offers the best protection. The permitted ambient conditions must be observed (see "Technical data"). If you have any questions, please contact your supplier or your local sales center. 3.2 Product identification 3.2.1 Type code for versions with explosion protection Name Type Condumax CLS15D CLS16D CLS21D Version - * ** * ** ** ** Process connections, materials not Ex-relevant Name Type Condumax CLS15D CLS16D CLS21D Name Type CLS15D CLS16D CLS21D - * ** * ** ** ** O O O For use in hazardous areas, FM/CSA IS/NI Cl I Div.1&2 Gr. A-D Version - * ** * ** ** ** Process connections, materials not Ex-relevant Endress+Hauser For use in hazardous areas, ATEX/NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga Version Process connections, materials not Ex-relevant Condumax G G G V V V For use in hazardous areas, ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc 9 Incoming acceptance and product identification 3.2.2 Condumax CLS15D/16D/21D Nameplate The nameplate provides you with the following information on your device: • Manufacturer identification • Extended order code • Serial number • Safety information and warnings • Cell constant (nominal value) • Protection class • Ex labeling on hazardous area versions ‣ Compare the data on the nameplate with your order. 3.2.3 Product identification Product page www.endress.com/cls15d www.endress.com/cls16d www.endress.com/cls21d Interpreting the order code The order code and serial number of your product can be found in the following locations: • On the nameplate • In the delivery papers Obtaining information on the product 1. Go to the product page for your product on the Internet. 2. At the bottom of the page, select the "Online Tools" link followed by "Check your device features".  An additional window opens. 3. Enter the order code from the nameplate into the search field, and then select "Show details".  You will receive information on each feature (selected option) of the order code. Manufacturer's address Endress+Hauser Conducta GmbH+Co. KG Dieselstraße 24 D-70839 Gerlingen 3.3 Scope of delivery The scope of delivery includes: • Sensor in the version ordered • Operating Instructions 10 Endress+Hauser Condumax CLS15D/16D/21D 3.4 Certificates and approvals 3.4.1  mark Incoming acceptance and product identification Declaration of conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the  mark. 3.4.2 Hazardous area approvals ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga FM/CSA IS/NI Cl. I Div.1&2 Gr. A-D in conjunction with Liquiline M CM42 transmitter ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc for use in Zone 2 with Liquiline M CM42-KV*** transmitter ATEX and FM/CSA versions of digital sensors with Memosens technology are indicated by a red-orange ring in the plug-in head. 3.4.3 EHEDG (CLS16D only) Validated as follows: • Cleanability in accordance with EHEDG, Document 2 • Sterilizability in accordance with EHEDG, Document 5 • Bacteria-tightness in accordance with EHEDG, Document 7 3.4.4 FDA (CLS16D only) All materials in contact with the product are listed by the FDA. 3.4.5 Manufacturer inspection certificate Stating the individual cell constant 3.4.6 Biological reactivity test (USP class VI, CLS16D only) Biological reactivity test certificate according to USP (United States Pharmacopeia)part <87> and part <88> class VI with batch traceability of materials in contact with the medium 3.4.7 Inspection certificate in accordance with EN 10204 3.1 A test certificate 3.1 in accordance with EN10204 is supplied depending on the version (→ Product Configurator on the product page). 3.4.8 ASME (CLS16D only) Manufactured in accordance with ASME criteria (American Society of Mechanical Engineers) 3.4.9 Certification body DEKRA EXAM GmbH Bochum Endress+Hauser 11 Installation Condumax CLS15D/16D/21D 4 Installation 4.1 Mounting the sensor 4.1.1 CLS15D The sensors are installed directly via the process connection thread NPT ½" or ¾" or clamp 1 ½". As an option, the sensor can also be installed using a commercially available Tpiece or cross fitting or using a flow assembly. NOTICE Incorrect mounting or disassembly The Memosens head could become loose and fall off, resulting in total sensor failure ‣ Only mount the sensor via the process connection. ‣ To do so, use a suitable tool, such as an open-ended wrench. 12 Endress+Hauser Installation 25 (0.98) Condumax CLS15D/16D/21D 1 3 NPT ½” 1 30 (1.18) 35 (1.38) 160 (6.30) 38.5 (1.52) 3 Ø 6 (0.24) 2 2 Ø 6 (0.24) Ø 29 (1.14) A0019015 1 1 2 3 With NPT ½" thread in T-piece or cross fitting T-piece or cross fitting (DN 32, 40 or 50) Glue-in VC threaded coupling (NPT ½" for DN 20) Glue-in adapter coupling (for DN 32, 40, 50) A0019014 2 1 2 3 With NPT ½" thread in flow assembly 71042405, dimensions in mm (inch) Sensor holder NPT ½" Inlet Outlet Ensure that the electrodes are fully immersed in the medium during measurement. The immersion depth must be at least 35 mm (1.38"). If the sensor is being used in the ultrapure water range, you must work under air-evacuated conditions. Otherwise the CO2 in the air can dissolve in the water and its (weak) dissociation can increase the conductivity by up to 3 µS/cm. Endress+Hauser 13 Installation 4.1.2 Condumax CLS15D/16D/21D CLS16D The sensors are installed directly via the process connection. Take the flow direction into consideration when installing in pipes. A0019017 A0019016 3 Permitted flow direction 4 Inadmissible flow direction Ensure that the electrodes are fully immersed in the medium during measurement. If the sensor is being used in the ultrapure water range, you must work under air-evacuated conditions. Otherwise the CO2 in the air can dissolve in the water and its (weak) dissociation can increase the conductivity by up to 3 µS/cm. 4.1.3 CLS21D Clamp connection Both sheet-metal brackets and solid brackets can be used to secure the sensor. Sheetmetal brackets have a lower dimensional stability, uneven bearing surfaces causing point loads, and sometimes sharp edges that can damage the clamp. We recommend you only use solid brackets due to their higher dimensional stability. Solid brackets can be used over the entire pressure/temperature range (see pressure-temperature ratings). 14 Endress+Hauser Condumax CLS15D/16D/21D Installation The sensors are installed directly via the process connection. As an option, the sensor can also be installed via a flow assembly. NOTICE Incorrect mounting or disassembly The Memosens head could become loose and fall off, resulting in total sensor failure ‣ Only mount the sensor via the process connection. ‣ To do so, use a suitable tool, such as an open-ended wrench. A0019019 5 Installation in flow assembly CLA751 Endress+Hauser A0019020 6 Installation in flow assembly CLA752 15 Electrical connection Condumax CLS15D/16D/21D The Dipfit CLA111 immersion assembly is available to install sensors with a G1 thread in vessels. A B D A0024145 7 Installation in Dipfit CLA111 immersion assembly, fastening versions A, B and D Ensure that the electrodes are fully immersed in the medium during measurement. 4.2 Post-installation check • Are the sensor and cable undamaged? • Is the sensor installed in the process connection and is not suspended from the cable? 5 Electrical connection LWARNING Device is live Incorrect connection may result in injury or death ‣ The electrical connection may be performed only by an electrical technician. ‣ The electrical technician must have read and understood these Operating Instructions and must follow the instructions contained therein. ‣ Prior to commencing connection work, ensure that no voltage is present on any cable. 16 Endress+Hauser Condumax CLS15D/16D/21D Electrical connection 5.1 Connection conditions 5.1.1 Connection at a glance Sensors for zone 0 IIC 3G Zone 2 EX Zone 1 IIC 2G EX CPS11D CPS12D CPS71D CPS72D CPS91D CPS92D CPS16D CPS76D CPS96D CPS171D CPS41D CPS42D CYK10 Ex ia Ga CPS341D Zone 0 IIC 1G CYK10 Ex ia Ga CLS16D CLS15D COS22D CLS21D CPS471D CPS491D CPS441D COS51D CLS50D CLS82D A0031174 8 Electrical connection in hazardous environment Endress+Hauser 17 Electrical connection Condumax CLS15D/16D/21D Sensors for zone 2 EX CYK10 Ex ic CPS11D CPS12D CPS71D CPS72D CPS91D CPS92D CPS16D CPS76D CPS96D CPS171D CPS41D CPS42D Zone 2 II 3G EX CYK10 Ex ic CPS341D CLS16D CLS15D COS22D CLS21D CPS471D CPS491D CPS441D COS51D CLS50D CLS82D A0031184 9 18 Electrical connection in hazardous environment Endress+Hauser Condumax CLS15D/16D/21D 5.2 Electrical connection Connecting the sensor The electrical connection of the sensor to the transmitter is performed using the measuring cable CYK10. GY GND YE Com B GN Com A WH – BN + EY/NG A0024019  10 Measuring cable CYK10 NOTICE Mechanical twist protection for CLS15D and CLS21D If too much force is applied to the Memosens head, this can shear the connections and therefore destroy the sensor ‣ There is no need to exert excessive force when connecting the sensor to the cable coupling. Always connect the sensor gently. ‣ If the Memosens coupling clearly will not close, check the coupling for dirt or mechanical damage and make sure you are turning in the right direction. Pay attention to the lock symbol on the coupling. ‣ Use another Memosens cable if necessary. 5.3 Ensuring the degree of protection Only the mechanical and electrical connections which are described in these instructions and which are necessary for the required, designated use, may be carried out on the device delivered. ‣ Exercise care when carrying out the work. Otherwise, the individual types of protection (Ingress Protection (IP), electrical safety, EMC interference immunity) agreed for this product can no longer be guaranteed due, for example, to covers being left off or cable (ends) which are loose or insufficiently secured. 5.4 Post-connection check Device condition and specifications Notes Are the outside of the sensor, assembly, cable undamaged? Visual inspection Electrical connection Notes Are the installed cables strain-relieved and not twisted? Is a sufficient length of the cable cores stripped, and is it positioned in the terminal correctly? Check the fit (by pulling gently) Are all the screws terminals properly tightened? Tighten Endress+Hauser 19 Commissioning Condumax CLS15D/16D/21D Device condition and specifications Notes Are all cable entries mounted, tightened and leak-tight? For lateral cable entries, make sure the cables loop downwards to allow water to drip off Are all cable entries installed downwards or mounted laterally? 6 Commissioning Before first commissioning, check if: • the sensor is correctly installed • the electrical connection is correct. If using an assembly with automatic cleaning, check that the cleaning medium (e.g. water or air) is connected correctly. LWARNING Escaping process medium Risk of injury from high pressure, high temperatures or chemical hazards ‣ Before applying compressed air to an assembly with cleaning facility, make sure the connections are correctly fitted. ‣ Do not install the assembly in the process if you cannot make the correct connection reliably. 7 Maintenance LCAUTION Corrosive chemicals Danger of chemical burns to the eyes and skin. Danger of damage to clothing and equipment ‣ It is absolutely essential to protect the eyes and hands properly when working with acids, bases and organic solvents! ‣ Wear protective goggles and safety gloves. ‣ Clean away splashes on clothes and other objects to prevent any damage. ‣ Pay particular attention to the information provided in the safety data sheets for the chemicals used. LWARNING Hydrofluoric acid and mineral acids Risk of serious or fatal injury from caustic burns ‣ Wear protective goggles to protect your eyes. ‣ Wear protective gloves and appropriate protective clothing. ‣ Avoid all contact with the eyes, mouth and skin. ‣ If using hydrofluoric acid, only use plastic vessels. 20 Endress+Hauser Condumax CLS15D/16D/21D Repair LWARNING Thiocarbamide Harmful if swallowed. Limited evidence of carcinogenicity. Possible risk of harm to the unborn child. Dangerous for the environment with long-term effects. ‣ Wear protective goggles, protective gloves and appropriate protective clothing. ‣ Avoid all contact with the eyes, mouth and skin. ‣ Avoid releases into the environment. Clean away fouling on the sensor as follows depending on the type of fouling: 1. Oily and greasy films: Clean with grease remover, e.g. alcohol, as well as hot water and (alkaline) agents containing surfactants (e.g. dishwashing detergent). 2. Lime, cyanide and metal hydroxide buildup and low solubility organic buildup: Dissolve buildup with diluted hydrochloric acid (3 %) and then rinse thoroughly with plenty of clear water. 3. Sulfidic buildup (from flue gas desulfurization or sewage treatment plants): Use a mixture of hydrochloric acid (3 %) and thiocarbamide (commercially available) and then rinse thoroughly with plenty of clear water. 4. Buildup containing proteins (e.g. food industry): Use a mixture of hydrochloric acid (0.5 %) and pepsin (commercially available) and then rinse thoroughly with plenty of clear water. 5. Readily soluble biological buildup: Rinse with pressurized water. After cleaning or regeneration, you must rinse the sensor thoroughly with water and then recalibrate it. 8 Repair 8.1 Sealing ring replacement and recalibration (CLS16D only) Intact seals are a prerequisite for safe and reliable measurements. The seal should be replaced at regular intervals to guarantee maximum sensor operational safety and hygiene. Practical repair intervals can only be determined by the user as they depend greatly on the operating conditions, such as: • Type and temperature of the product • Type and temperature of the cleaning agent • Number of cleanings • Number of sterilizations • Operating environment Endress+Hauser 21 Repair Condumax CLS15D/16D/21D Recommended intervals for seal replacement (reference values) Application Window Media with temperatures from 50 to 100 °C (122 to 212 °F) Approx. 18 months Media with temperatures < 50 °C (122 °F) Approx. 36 months Sterilization cycles, max. 150 °C (302 °F), 45 min. Approx. 400 cycles To ensure your sensor is operational again after being exposed to very high loads, you can have it regenerated in the factory. In the factory, the sensor is fitted with new seals and recalibrated. Please contact your sales office for information on replacing the seal and recalibration in the factory. 8.2 Return The product must be returned if repairs or a factory calibration are required, or if the wrong product was ordered or delivered. As an ISO-certified company and also due to legal regulations, Endress+Hauser is obliged to follow certain procedures when handling any returned products that have been in contact with medium. To ensure swift, safe and professional device returns, please read the return procedures and conditions at www.endress.com/support/return-material. 8.3 Disposal The device contains electronic components and must therefore be disposed of in accordance with regulations on the disposal of electronic waste. Observe the local regulations. 22 Endress+Hauser Condumax CLS15D/16D/21D 9 Technical data 9.1 Input 9.1.1 Measured values Technical data • Conductivity • Temperature 9.1.2 Measuring ranges Conductivity CLS15D-A CLS15D-B/L CLS16D CLS21D Temperature CLS15D CLS16D CLS21D 9.1.3 -20 to 100 °C (-4 to 212 °F) -5 to 100 °C (23 to 212 °F) -20 to 100 °C (-4 to 212 °F) Cell constant CLS15D-A CLS15D-B/L CLS16D CLS21D 9.1.4 (in relation to water at 25 °C (77 °F)) 0.04 to 20 μS/cm 0.10 to 200 μS/cm 0.04 to 500 μS/cm 10 μS/cm to 20 mS/cm k = 0.01 cm–1 k = 0.1 cm–1 k = 0.1 cm–1 k = 1.0 cm–1, nominal Temperature compensation NTC 30K Endress+Hauser 23 Technical data Condumax CLS15D/16D/21D 9.2 Performance characteristics 9.2.1 Uncertainty of measurement CLS15D Each individual sensor is factory-measured in a solution of approx. 5 μS/cm for cell constant 0.01 cm-1 or approx. 50 μS/cm for cell constant 0.1 cm-1 using a reference measuring system traceable to NIST or PTB. The exact cell constant is entered into the quality certificate supplied. The uncertainty of measurement in determining the cell constant is 1.0 %. CLS16D Each individual sensor is factory-measured in a solution of approx. 5 μS/cm using a reference measuring system traceable to NIST or PTB. The exact cell constant is entered into the quality certificate supplied. The uncertainty of measurement in determining the cell constant is 1.0 %. CLS21D Each individual sensor is factory-measured in a solution of approx. 5 mS/cmusing a reference measuring system traceable to NIST or PTB. The exact cell constant is entered into the quality certificate supplied. The uncertainty of measurement in determining the cell constant is 1.0 %. 9.2.2 Response time Conductivity Temperature CLS15D-A CLS15D-B/L CLS16D CLS21D 9.2.3 t90 ≤ 39 s t90 ≤ 17 s t90 ≤ 13 s t90 ≤ 296 s Maximum measured error CLS15D CLS16D 2% of reading 2 % of reading up to 200 μS/cm 3 % of reading from 200 to 500 μS/cm 5% of reading CLS21D 9.2.4 t95 ≤ 3 s Repeatability 0.2% of reading 24 Endress+Hauser Condumax CLS15D/16D/21D 9.3 Environment 9.3.1 Ambient temperature range Technical data -20 to +60 °C (-4 to 140 °F) 9.3.2 Storage temperature -25 to +80 °C (-10 to +180 °F) 9.3.3 Degree of protection IP 68 / NEMA type 6P (1 m water column, 25 °C, 24 h) 9.4 Process 9.4.1 Process temperature CLS15D Normal operation Sterilization (max. 1 h) 1) CLS16D Normal operation Sterilization (max. 45 min) CLS21D 1) -20 to 120 °C (-4 to 248 °F) Max. 140 °C (284 °F) -5 to 120 °C (23 to 248 °F) Max. 150 °C (302 °F) at 6 bar (87 psi) absolute -20 to +135 °C (-4 to 275 °F) at 3.5 bar (50 psi) absolute Threaded versions: max. 30 minutes The maximum temperature for communication with the transmitter is 130 °C (266°F) for the Memosens versions. 9.4.2 Process pressure CLS15D CLS16D CLS21D Endress+Hauser 13 bar (188 psi) absolute, at 20 °C (68 °F) 2 bar (29 psi) absolute, at 120 °C (248 °F) 13 bar (188 psi) absolute, at 20 °C (68 °F) 9 bar (130 psi) absolute, at 120 °C (248 °F) 0.1 bar (1.5 psi) absolute (negative pressure), at 20 °C (68 °F) 17 bar (246 psi) absolute, at 20 °C (68 °F) 25 Technical data 9.4.3 Condumax CLS15D/16D/21D Temperature/pressure ratings CLS15D p (abs.) [psi] [bar] 188 13 159 11 130 9 101 7 72 5 43 3 14 1 –20 -4 0 20 40 60 80 100 120 140 68 212 248 284 20 60 100 140 180 220 260 [°C] T [°F] A A0031428-EN  11 A Mechanical pressure-temperature resistance Can be sterilized for a short time (1 hour) CLS16D p (abs.) [psi] [bar] 188 13 159 11 130 9 101 7 87 6 72 5 43 3 14 1.5 A 1 0.1 –5 23 20 68 60 100 120 150 [°C] 60 120 180 248 240 T 302 300 [°F] A0031431-EN  12 A 26 Mechanical pressure-temperature resistance Can be sterilized for a short time (45 min.) Endress+Hauser Condumax CLS15D/16D/21D Technical data CLS21D p (abs.) [psi] [bar] 246 17 188 13 130 9 72 5 51 14 3.5 1 -20 0 -4 20 20 30 60 90 120 68 60 100 140 180 220 135 [°C] T 275 [°F] A0031435-EN  13 Mechanical pressure-temperature resistance 9.5 Mechanical construction 9.5.1 Weight CLS15D and CLS21D Approx. 0.3 kg (0.66 lbs) depending on version CLS16D Approx. 0.13 to 0.75 kg (0.29 to 1.65 lbs) depending on version 9.5.2 Materials CLS15D Electrodes Sensor shaft O-ring, in contact with medium (only Clamp version) CLS16D Electrodes Seal CLS21D Electrodes Sensor shaft Thermal conductivity socket for temperature probe Endress+Hauser Polished, stainless steel 1.4435 (AISI 316L) Polyethersulfone (PES-GF20) EPDM Electropolished, stainless steel 1.4435 (AISI 316L) Gasket seal ISOLAST (FFKM), FDA-compliant Graphite Polyethersulfone (PES-GF20) Titanium 3.7035 27 Technical data 9.5.3 Condumax CLS15D/16D/21D Process connection CLS15D Thread NPT ½" and ¾" Clamp 1½" as per ISO 2852 CLS16D Clamp 1", 1½", 2" as per ISO 2852 (also suitable for TRI-CLAMP, DIN 32676) Tuchenhagen VARIVENT N DN 50 to 125 NEUMO BioControl D50 CLS21D Thread G1 NPT 1" thread Clamp 2" as per ISO 2852 Sanitary connection DN 25 as per DIN 11851 9.5.4 Surface roughness (CLS15D, CLS16D only) CLS15D Ra ≤ 0.8 μm CLS16D Ra ≤ 0.8 μm, electropolished Ra ≤ 0.38 μm, electropolished, optional 28 Endress+Hauser Condumax CLS15D/16D/21D EU Declaration of conformity 10 EU Declaration of conformity 10.1 ATEX / NEPSI II 1G Ex ia IIC T3/T4/T6 Ga, IECEx Ex ia IIC T3/T4/T6 Ga Endress+Hauser 29 EU Declaration of conformity 10.2 30 Condumax CLS15D/16D/21D ATEX/NEPSI II 3G Ex ic IIC T3/T4/T6 Gc Endress+Hauser *71333350* 71333350 www.addresses.endress.com