Endress + Hauser Operating Instructions Indumax CLS50D/ CLS50 Digital sensor with Memosens protocol or analog sensor
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
BA00182C/07/EN/18.16
71325826
Products
Solutions
Services
Operating Instructions
Indumax CLS50D/ CLS50
Digital sensor with Memosens protocol or analog
sensor
For inductive measurement of conductivity in
liquids
0
Table of contents
Table of contents
1
Document information . . . . . . . . . 3
1.1
1.2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2
Basic safety instructions . . . . . . . 4
2.1
2.2
2.3
2.4
2.5
Requirements for personnel . . . . . . . . . . .
Designated use . . . . . . . . . . . . . . . . . . . . . .
Workplace safety . . . . . . . . . . . . . . . . . . . .
Operational safety . . . . . . . . . . . . . . . . . . .
Product safety . . . . . . . . . . . . . . . . . . . . . . .
3
Incoming acceptance and
product identification . . . . . . . . . . 9
3.1
3.2
3.3
3.4
Incoming acceptance . . . . . . . . . . . . . . . . . 9
Product identification . . . . . . . . . . . . . . . . . 9
Scope of delivery . . . . . . . . . . . . . . . . . . . . 12
Certificates and approvals . . . . . . . . . . . . 13
4
Installation . . . . . . . . . . . . . . . . . . . . 14
4.1
4.2
4.3
Installation conditions . . . . . . . . . . . . . . . 14
Mounting the sensor . . . . . . . . . . . . . . . . 16
Post-installation check . . . . . . . . . . . . . . . 19
4
4
4
5
5
5
Electrical connection . . . . . . . . . . 19
5.1
5.2
5.3
5.4
Connection conditions . . . . . . . . . . . . . . .
Connecting the sensor . . . . . . . . . . . . . . .
Ensuring the degree of protection . . . . .
Post-connection check . . . . . . . . . . . . . . .
6
Commissioning . . . . . . . . . . . . . . . . 26
7
Maintenance . . . . . . . . . . . . . . . . . . 26
20
24
25
25
8
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8.1
8.2
8.3
Spare parts . . . . . . . . . . . . . . . . . . . . . . . . 28
Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
9
Technical data . . . . . . . . . . . . . . . . . 30
10
EU Declaration of
conformity . . . . . . . . . . . . . . . . . . . . . 36
10.1
10.2
10.3
10.4
CLS50D-BA**** . . . . . . . . . . . . . . . . . . . .
CLS50-G*** . . . . . . . . . . . . . . . . . . . . . . .
CLS50D-BV**** . . . . . . . . . . . . . . . . . . . .
CLS50-V*** . . . . . . . . . . . . . . . . . . . . . . .
2
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
36
37
38
39
Endress+Hauser
Indumax CLS50D/ CLS50
Document information
1
Document information
1.1
Warnings
Structure of information
LDANGER
Causes (/consequences)
Consequences of non-compliance (if
applicable)
‣ Corrective action
LWARNING
Causes (/consequences)
Consequences of non-compliance (if
applicable)
‣ Corrective action
LCAUTION
Causes (/consequences)
Consequences of non-compliance (if
applicable)
‣ Corrective action
NOTICE
Meaning
This symbol alerts you to a dangerous situation.
Failure to avoid the dangerous situation will result in a fatal or serious injury.
This symbol alerts you to a dangerous situation.
Failure to avoid the dangerous situation can result in a fatal or serious injury.
This symbol alerts you to a dangerous situation.
Failure to avoid this situation can result in minor or more serious injuries.
This symbol alerts you to situations which may result in damage to property.
Cause/situation
Consequences of non-compliance (if
applicable)
‣ Action/note
1.2
Symbols
Symbol
Meaning
Additional information, tips
Permitted or recommended
Not permitted or not recommended
Reference to device documentation
Reference to page
Reference to graphic
Endress+Hauser
Result of a step
3
Basic safety instructions
2
Basic safety instructions
2.1
Requirements for personnel
Indumax CLS50D/ CLS50
• Installation, commissioning, operation and maintenance of the measuring system may be
carried out only by specially trained technical personnel.
• The technical personnel must be authorized by the plant operator to carry out the specified
activities.
• The electrical connection may be performed only by an electrical technician.
• The technical personnel must have read and understood these Operating Instructions and
must follow the instructions contained therein.
• Measuring point faults may be repaired only by authorized and specially trained personnel.
Repairs not described in the Operating Instructions provided may only be carried out
directly by the manufacturer or by the service organization.
2.2
Designated use
Indumax CLS50/CLS50D is particularly suitable for use in the chemical industry and process
engineering. The six-decade measuring range and the excellent chemical resistance properties
of the materials in contact with the medium (PFA or PEEK) make it possible to use this sensor
in a wide ranges of applications, such as:
• Concentration measurement of acids and bases
• Quality monitoring of chemical products in tanks and pipes
• Phase separation of product/product mixtures
The CLS50D digital sensor is used with Liquiline CM44x or Liquiline M CM42, while the
CLS50 analog sensor is used with the Liquiline M CM42, Liquisys CLM223/253 or
Mycom CLM153 transmitters.
Use of the device for any purpose other than that described, poses a threat to the safety of
people and of the entire measuring system and is therefore not permitted.
The manufacturer is not liable for damage caused by improper or non-designated use.
NOTICE
Non-designated use
Incorrect measurements, malfunctions and even measuring point failure could result
‣ Only use the product in accordance with the product specifications.
‣ Pay particular attention to the technical data on the nameplate.
2.3
Workplace safety
As the user, you are responsible for complying with the following safety conditions:
• Installation guidelines
• Local standards and regulations
• Regulations for explosion protection
4
Endress+Hauser
Indumax CLS50D/ CLS50
Basic safety instructions
Electromagnetic compatibility
• The product has been tested for electromagnetic compatibility in accordance with the
applicable European standards for industrial applications.
• The electromagnetic compatibility indicated applies only to a product that has been
connected in accordance with these Operating Instructions.
2.4
Operational safety
1.
Before commissioning the entire measuring point, verify that all connections are
correct. Ensure that electrical cables and hose connections are undamaged.
2.
Do not operate damaged products, and safeguard them to ensure that they are not
operated inadvertently. Label the damaged product as defective.
3.
If faults cannot be rectified:
Take the products out of operation and safeguard them to ensure that they are not
operated inadvertently.
2.5
Product safety
2.5.1
State of the art
The product is designed to meet state-of-the-art safety requirements, has been tested, and
left the factory in a condition in which it is safe to operate. The relevant regulations and
European standards have been observed.
2.5.2
Electrical equipment in hazardous areas
Sensors with ATEX approval (CLS50-G*** and CLS50D-BA**** for Zone 0, CLS50-V*** and
CLS50D-BV**** for Zone 2) have been developed and manufactured in compliance with
applicable European standards and guidelines and are suitable for use in hazardous locations.
The Declaration of Conformity confirms compliance with the harmonized European standards
for using the sensors in hazardous areas.
CLS50D-BA****, CLS50D-IA****, CLS50D-GB****, CLS50D-NA****, CLS50D-H****,
CLS50-G*** and CLS50-K***
• The sensors may be operated in an environment specified as Ex Zone 0 (1G).
• The sensors may only be used in liquid media with a conductivity >10 nS/cm.
• If the connecting cable runs through Ex Zone 0 (1G), it must be protected against
electrostatic charge.
CLS50D-BA****, CLS50D-IA****, CLS50D-NA**** and CLS50D-GB****
• The sensor is a digital sensor with the Memosens protocol and its connection values are
those specified below.
• The sensor may also be connected to the intrinsically safe Memosens connection of the
FSDG1 module of the Liquiline transmitter, types CM42-LE, CM42-LF, CM42-LI, EC typeexamination certificate EX5 05 03 30266 012 (ATEX or IECEx) or CM42-LK (EAC Ex).
• The maximum permitted length of the measuring cable is 100 m (330 ft) here.
Endress+Hauser
5
Basic safety instructions
Indumax CLS50D/ CLS50
Connection values of the CLS50D-BA****, CLS50D-IA**** and CLS50D-GB**** sensor
Ui
5.1 V
Ii
130 mA
Pi
166 mW
Ci
18 µF
Li
72 µH
Temperature classes of CLS50D-BA****, CLS50D-IA**** and CLS50D-GB****
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50D-BA/IA/
GB*D**
CLS50D-BA/IA/
GB*C**
CLS50D-BA/IA/
GB*B**
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +110 ˚C
-20 to +120 ˚C
-20 to +120 ˚C
T6
CLS50D-BA/IA/
GB*D**
CLS50D-BA/IA/
GB*C**
CLS50D-BA/IA/
GB*B**
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +70 ˚C
-20 to +70 ˚C
-20 to +70 ˚C
CLS50-G***
• The sensor may only be connected to the following transmitters:
– Liquiline types CM42-IG, CM42-IE, CM42-IF, EC type-examination certificate TÜV 13
ATEX 7459 X
– Mycom type CLM153-Z with transmitter module type FCL1, EC type-examination
certificate DMT 99 ATEX E 076
– Mycom type CLM153-G, EC type-examination certificate DMT 01 ATEX E 174
• The maximum permitted length of the measuring cable is 55 m (180 ft) here.
Temperature classes of CLS50-G***
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50-G***
-20 to +125 ˚C
-20 to +125 ˚C
T6
CLS50-G***
-20 to +75 ˚C
-20 to +75 ˚C
CLS50D-BV**** and CLS50-V***
• The sensor may be operated in an environment specified as Ex Zone 2 (3G).
• The sensor may only be connected to the following transmitter:
Liquiline type CM42-LV (CLS50D) or CM42-IV (CLS50), EU Declaration of Conformity
EC_00143_01.16
• Only CLS50-V***: The maximum permitted length of the measuring cable is 55 m (180 ft)
here.
6
Endress+Hauser
Indumax CLS50D/ CLS50
Basic safety instructions
Temperature classes of CLS50D-BV****
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50D-BV*D**
CLS50D-BV*C**
CLS50D-BV*B**
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +110 ˚C
-20 to +120 ˚C
-20 to +120 ˚C
T6
CLS50D-BV****
-20 to +60 ˚C
-20 to +70 ˚C
Temperature classes of CLS50-V***
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50-V***
-20 to +125 ˚C
-20 to +125 ˚C
T6
CLS50-V***
-20 to +75 ˚C
-20 to +75 ˚C
CLS50-K***
• The sensor may only be connected to the following transmitter:
Liquiline type CM42-IK
• The maximum permitted length of the measuring cable is 55 m (180 ft) here.
Temperature classes of CLS50-K***
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50-K***
-20 to +125 ˚C
-20 to +125 ˚C
T6
CLS50-K***
-20 to +75 ˚C
-20 to +75 ˚C
Sensors with FM and CSA approval (CLS50D-FB****, CLS50D-C2****, CLS50-O***,
CLS50-S***)
Observe the documentation and the control drawings of the transmitter.
Sensors with NEPSI approval (CLS50D-NA**** and CLS50-H*** for Zone 0, CLS50-V***
for Zone 2)
Pay attention to the information on the NEPSI certificates. You can download these
certificates from the product page: www.endress.com/cls50d or www.endress.com/cls50.
Temperature classes of CLS50D-NA****
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50D-NA*D**
CLS50D-NA*C**
CLS50D-NA*B**
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +110 ˚C
-20 to +120 ˚C
-20 to +120 ˚C
T6
CLS50D-NA*D**
CLS50D-NA*C**
CLS50D-NA*B**
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +60 ˚C
-20 to +70 ˚C
-20 to +70 ˚C
-20 to +70 ˚C
Endress+Hauser
7
Basic safety instructions
Indumax CLS50D/ CLS50
Temperature classes of CLS50-H***
Temperature class
Sensor
Ambient temperature range Ta
Medium temperature range Tmed
T4
CLS50-H***
-20 to +125 ˚C
-20 to +125 ˚C
T6
CLS50-H***
-20 to +75 ˚C
-20 to +75 ˚C
Sensors with TIIS approval (CLS50D-TA****, CLS50-T***)
Sensors with TIIS approval may only be used in a Zone 1 (2G) environment.
The following also applies for all the sensors listed
• Compliance with the specified ambient and medium temperature ranges is a prerequisite
for safe use.
• The sensor must be connected and operated in accordance with the Operating Instructions
of the sensor and of the transmitter to be connected. All sensor operating data must be
observed.
• Avoid electrostatic charge. Metal process connections must be electrostatically connected (R
≤ 1 MΩ).
• Non-metal process connections must be protected against electrostatic charge.
• In order to avoid electrostatic charge clean the sensor with a damp cloth only.
• Full compliance with regulations for electrical systems in hazardous locations
(EN60079-14) is mandatory when using the devices and sensors.
• Ensure correct installation to maintain the housing protection type. (Use original seal. Fit
cable entry properly. Tighten nut).
• The degree of protection only applies when the flange is mounted.
CLS50 only
In the CLS50 sensor, the internal sensor circuits are connected with the shielded wire of
the supply cable. When installing the CM42 or CLM153 transmitter, the shielding of the
sensor cable must be connected to functional ground as prescribed. As a result, the
intrinsically safe sensor circuits of CLS50 are also connected to ground. Therefore, the
power supply of the transmitter must be galvanically isolated and connected to ground.
The CM42 and CLM153 transmitters already have secure internal galvanic isolation and
therefore safely separate the sensor circuit from the other circuits.
8
Endress+Hauser
Indumax CLS50D/ CLS50
Incoming acceptance and product identification
3
Incoming acceptance and product identification
3.1
Incoming acceptance
1.
Verify that the packaging is undamaged.
Notify your supplier of any damage to the packaging.
Keep the damaged packaging until the matter has been settled.
2.
Verify that the contents are undamaged.
Notify your supplier of any damage to the delivery contents.
Keep the damaged products until the matter has been settled.
3.
Check the delivery for completeness.
Check it against the delivery papers and your order.
4.
Pack the product for storage and transportation in such a way that it is protected
against impact and moisture.
The original packaging offers the best protection.
The permitted ambient conditions must be observed (see "Technical data").
If you have any questions, please contact your supplier or your local sales center.
3.2
Product identification
3.2.1
Type code for versions with explosion protection
Name
Type
Indumax
CLS50D
Version
- BA
For use in hazardous areas, ATEX II 1G
Ex ia IIC T4/T6 Ga
Name
Type
Indumax
CLS50D
Type
Indumax
CLS50D
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
Version
- BV
For use in hazardous areas, ATEX II 3G
Ex ic IIC T4/T6 Gc
Endress+Hauser
x
Version
- IA
For use in hazardous areas, IECEx Ex ia
IIC T4/T6 Ga
Name
x
x
x
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
9
Incoming acceptance and product identification
Name
Type
Indumax
CLS50D
Version
- NA
For use in hazardous areas, NEPSI Ex ia
IIC T4/T6 Ga
Name
Type
Indumax
CLS50D
Type
Indumax
CLS50D
- C2
Type
Indumax
CLS50D
- FB
Type
Indumax
CLS50D
- GB
Type
Indumax
CLS50
- TA
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
B/C/ x
D
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
x
+
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
Version
- G
For use in hazardous areas, ATEX II 1G
Ex ia IIC T4/T6 Ga
10
x
Version
For use in hazardous areas, TIIS Ex ib IIC
T4 Gb
Name
x
Version
For use in hazardous areas, EAC Ex, 0Ex
ia IIC T6/T4 Ga X
Name
x
Version
For use in hazardous areas, FM IS NI
C1.I Div.1&2, Gr. A-D
Name
x
Version
For use in hazardous areas, CSA IS NI
Cl.I Div.1&2,Gr. A-D
Name
Indumax CLS50D/ CLS50
x
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
Endress+Hauser
Indumax CLS50D/ CLS50
Name
Type
Indumax
CLS50
Incoming acceptance and product identification
Version
- V
For use in hazardous areas, ATEX II 3G
Ex ic IIC T4/T6 Gc / NEPSI Ex ic IIC
T4/T6 Gc
Name
Type
Indumax
CLS50
Type
Indumax
CLS50
- H
Type
Indumax
CLS50
- O
Type
Indumax
CLS50
- S
Type
Indumax
CLS50
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
x
x
x
Process connections, materials, cable
connection, calibration, service
No Ex relevance
Version
- K
For use in hazardous areas, EAC Ex, 0Ex
ia IIC T6/T4 Ga X
Endress+Hauser
x
Version
- T
For use in hazardous areas, TIIS Ex ib IIC
T4 Gb
Name
Process connections, materials, cable
connection, calibration, service
No Ex relevance
Version
For use in hazardous areas, CSA IS NI
Cl.I Div.1&2,Gr. A-D
Name
x
Version
For use in hazardous areas, FM IS NI Cl.I
Div.1&2,Gr. A-D
Name
x
Version
For use in hazardous areas, NEPSI Ex ia
IIC T4/T6 Ga
Name
x
x
x
1/2
/
3/4
Process connections, materials, cable
connection, calibration, service
No Ex relevance
11
Incoming acceptance and product identification
3.2.2
Indumax CLS50D/ CLS50
Nameplate
The nameplate provides you with the following information on your device:
• Manufacturer identification
• Extended order code
• Serial number
• Safety information and warnings
• Cell constant (nominal value)
• Protection class
• Ex labeling on hazardous area versions
‣ Compare the data on the nameplate with your order.
3.2.3
Product identification
Product page
www.endress.com/cls50d
www.endress.com/cls50
Interpreting the order code
The order code and serial number of your product can be found in the following locations:
• On the nameplate
• In the delivery papers
Obtaining information on the product
1.
Go to the product page for your product on the Internet.
2.
At the bottom of the page, select the "Online Tools" link followed by "Check your device
features".
An additional window opens.
3.
Enter the order code from the nameplate into the search field, and then select "Show
details".
You will receive information on each feature (selected option) of the order code.
Manufacturer's address
Endress+Hauser Conducta GmbH+Co. KG
Dieselstraße 24
D-70839 Gerlingen
3.3
Scope of delivery
The scope of delivery includes:
• Sensor in the version ordered
• Operating Instructions
If you have any questions, please contact your supplier or your local sales center.
12
Endress+Hauser
Indumax CLS50D/ CLS50
3.4
Certificates and approvals
3.4.1
mark
Incoming acceptance and product identification
Declaration of Conformity
The product meets the requirements of the harmonized European standards. As such, it
complies with the legal specifications of the EU directives. The manufacturer confirms
successful testing of the product by affixing to it the mark.
3.4.2
Ex approvals
CLS50D-BA**** and CLS50-G***
ATEX II 1G Ex ia IIC T4/T6 Ga
CLS50D-BV****
ATEX II 3G Ex ic IIC T4/T6 Gc
CLS50D-IA****
IECEx Ex ia IIC T4/T6 Ga
CLS50-V***
ATEX II 3G Ex ic IIC T4/T6 Gc + NEPSI Ex ic IIC T4/T6 Gc
CLS50D-NA**** and CLS50-H***
NEPSI Ex ia IIC T4/T6 Ga
CLS50D-FB**** and CLS50-O***
FM IS NI Cl.I Div.1&2,G. A-D
CLS50D-C2**** and CLS50-S***
CSA IS NI Cl.I Div.1&2,Gr. A-D
CLS50D-TA**** and CLS50-T***
TIIS Ex ib IIC T4 Gb
CLS50D-GB**** and CLS50-K***
• EAC Ex, 0Ex ia IIC T6/T4 Ga X
• Zone 0
• Certificate number: TC RU C-DE.AA87.B.00088 and TC RU C-DE.ГБ05.B.00172 (only
CLS50-K***)
• The product has been certified in accordance with Directive TR CU 012/2011 which applies
in the European Economic Area (EEA). The EAC conformity mark has been affixed to the
product.
3.4.3
Certification body (only CLS50D-GB and CLS50-K)
OOO "НАНИО ЦСВЭ"
Russian Federation
Endress+Hauser
13
Installation
Indumax CLS50D/ CLS50
4
Installation
4.1
Installation conditions
4.1.1
Orientation
When installing, align the sensor in such a way that the medium flows through the flow
opening of the sensor in the direction of medium flow. The sensor head must be completely
immersed in the medium.
2
a
max. 100
(3.94)
1
A0024950
1
1
2
a
14
Sensor orientation, dimensions in mm (inch)
Direction of medium flow
Minimum water level in the pipe
Distance from pipe wall
Endress+Hauser
Indumax CLS50D/ CLS50
4.1.2
Installation
Installation factor
In confined installation conditions, the conductivity measurement is affected by the pipe walls.
The installation factor compensates for this effect. The transmitter corrects the cell constant
by multiplying by the installation factor. The value of the installation factor depends on the
diameter and the conductivity of the pipe nozzle as well as the sensor's distance to the wall.
The installation factor f can be disregarded (f = 1.00) if the distance to the wall is sufficient (a
> 15 mm (0.59"), from DN 80). If the distance to the wall is smaller, the installation factor
increases for electrically insulating pipes (f > 1) and decreases for electrically conductive pipes
(f < 1). It can be measured using calibration solutions, or a close approximation determined
from the following diagram.
f
1.40
2
1.20
1.00
1
0.80
0
5
10
15
20
0.20
0.39
0.59
0.79
25
a [mm]
0.98 a [inch]
A0005441
2
1
2
Relationship between installation factor f and wall distance
Electrically conductive pipe wall
Electrically insulating pipe wall
4.1.3
Air set
CLS50D
The digital sensor has already been adjusted at the factory. Onsite compensation is not
required.
CLS50
To compensate residual coupling in the cable and between the two sensor coils, zero
adjustment in air ("air set") must be performed before installing the sensor. Follow the
instructions provided in the Operating Instructions of the transmitter used.
Endress+Hauser
15
Installation
Indumax CLS50D/ CLS50
4.2
Mounting the sensor
4.2.1
Installation with flange
The sensor is suitable for installation in T-pieces ≥ DN 80, with the outgoing diameter reduced
to ≥ DN 50.
LWARNING
Leakage
Risk of injury if medium escapes
‣ Tighten the sensor nut with a torque of 20 Nm.
‣ To avoid leakages, regularly check the tightness of the nut.
Flange, not in contact with medium
1
2
3
5
4
A0024949
3
1
2
3
4
5
16
Fixed flange, not in contact with medium (for order option: "Process connection" = 5, 6, 7)
Flange (stainless steel)
Nut
Sealing disk (GYLON)
O-ring
Sensor
Endress+Hauser
Indumax CLS50D/ CLS50
Installation
Flange, in contact with medium
1
2
4
3
A0024953
4
1
2
3
4
Fixed flange, in contact with medium (for order option: "Process connection" = 3, 4)
Flange (stainless steel)
Nut
O-ring
Sensor
Endress+Hauser
17
Installation
Indumax CLS50D/ CLS50
Lap joint flange, not in contact with medium
1
2
5
3
4
A0024954
5
1
2
3
4
5
18
Lap joint flange, not in contact with medium (for order option: "Process connection" = A, B, C)
Lap joint flange (PP-GF)
Nut (stainless steel)
Flange (PVDF)
O-ring
Sensor
Endress+Hauser
Indumax CLS50D/ CLS50
4.2.2
Electrical connection
Installation in assembly
1
2
3
4
A0024960
6
1
2
3
4
4.3
Installation of sensor with assembly
CLA111 with suspension bracket
CLA111 with flange connection
CLA140 with flange connection
CYA112
Post-installation check
Put the sensor into operation only if you can answer "yes" to the following questions:
• Are the sensor and cable undamaged?
• Have you observed the correct orientation (arrow on the threaded sleeve=flow
direction=installation direction)?
• Has the sensor been installed in the process connection, and does not suspend freely from
the cable?
5
Electrical connection
LWARNING
Device is live
Incorrect connection may result in injury or death
‣ The electrical connection may be performed only by an electrical technician.
‣ The electrical technician must have read and understood these Operating Instructions and
must follow the instructions contained therein.
‣ Prior to commencing connection work, ensure that no voltage is present on any cable.
Endress+Hauser
19
Electrical connection
Indumax CLS50D/ CLS50
5.1
Connection conditions
5.1.1
Connection diagram: sensors for Zone 0 (ATEX/EAC Ex)
II 3G
Zone 2
EX
Zone 1
II 2G
EX
Ex ia
II 1G
Zone 0
Ex ia
CLS50D-BA
CLS50-G
CLS50-G
A0013258
20
Endress+Hauser
Indumax CLS50D/ CLS50
5.1.2
Electrical connection
Connection diagram: sensors for Zone 0 (IECEx)
EX
9
Zone 1
II 2G
EX
II 1G
Zone 0
Ex ia
CLS50D-IA
A0025482
Endress+Hauser
21
Electrical connection
5.1.3
Indumax CLS50D/ CLS50
Connection diagram: sensors for Zone 0 (NEPSI)
EX
9
Zone 1
II 2G
EX
II 1G
Zone 0
Ex ia
CLS50D-NA
CLS50-H
A0025481
22
Endress+Hauser
Indumax CLS50D/ CLS50
5.1.4
Electrical connection
Connection diagram: sensors for Zone 2 (ATEX/NEPSI)
EX
4...20 mA
Ex ic
CLS50D-BV
Zone 2
II 3G
EX
CLS50-V
A0010316
5.1.5
Sensors with FM or CSA approval
The instructions in the Control Drawing apply for sensors with FM or CSA approval. You can
find the Control Drawing in the Operating Instructions of the transmitter used.
Endress+Hauser
23
Electrical connection
Indumax CLS50D/ CLS50
5.2
Connecting the sensor
5.2.1
Direct connection, e.g. to CM42
CM42
Sensor cable
Sensor
CM42
Cable
Sensor
RD
187
188
197
BN
WH
GN
U+
215
U–
216
Com A
112
Com B
113
BU
RD
GN
J
198
YE
387
111
388
218
WH
YE
RD
WH
587
217
BU
588
A0001078
7
24
CLS50D to CM42
A0001082
8
CLS50 to CM42
Endress+Hauser
Indumax CLS50D/ CLS50
5.2.2
Electrical connection
Cable extension
The sensor is supplied with a fixed cable. The cable between the sensor and transmitter can be
extended using the CYK11 (CLS50D) or CLK6 (CLS50) special measuring cable (does not apply
for use in a hazardous environment).
WH U BN
GN
YE
GY
PK
RD
BU
RD
BU
Shield
U+
WH
Memosens
RD
Com A
Com B
+
GN
WH
YE
BN n.c.
Additional
sensor supply
Pt 100
GY
A0017984
9
CYK11 for extension for CLS50D
Max. total cable length: 100 m (330 ft)
A002493
10
CLK6 for extension for CLS50
Max. total cable length: 55 m (180 ft)
CLS50 only:
The residual coupling of the sensor increases when the fixed cable is extended.
5.3
Ensuring the degree of protection
Only the mechanical and electrical connections which are described in these instructions and
which are necessary for the required, designated use, may be carried out on the device
delivered.
‣ Exercise care when carrying out the work.
Otherwise, the individual types of protection (Ingress Protection (IP), electrical safety, EMC
interference immunity) agreed for this product can no longer be guaranteed due, for example,
to covers being left off or cable (ends) which are loose or insufficiently secured.
5.4
Post-connection check
Device condition and specifications
Notes
Are the outside of the sensor, assembly, cable undamaged?
Visual inspection
Electrical connection
Notes
Are the installed cables strain-relieved and not twisted?
Is a sufficient length of the cable cores stripped, and is it positioned
in the terminal correctly?
Check the fit (by pulling gently)
Are all the screws terminals properly tightened?
Tighten
Are all cable entries mounted, tightened and leak-tight?
For lateral cable entries, make sure the cables
loop downwards to allow water to drip off
Are all cable entries installed downwards or mounted laterally?
Endress+Hauser
25
Commissioning
6
Indumax CLS50D/ CLS50
Commissioning
Before first commissioning, check if:
• the sensor is correctly installed
• the electrical connection is correct.
If using an assembly with automatic cleaning, check that the cleaning medium (e.g. water or
air) is connected correctly.
LWARNING
Escaping process medium
Risk of injury from high pressure, high temperatures or chemical hazards
‣ Before applying compressed air to an assembly with cleaning facility, make sure the
connections are correctly fitted.
‣ Do not install the assembly in the process if you cannot make the correct connection
reliably.
7
Maintenance
LCAUTION
Corrosive chemicals
Danger of chemical burns to the eyes and skin. Danger of damage to clothing and equipment
‣ It is absolutely essential to protect the eyes and hands properly when working with acids,
bases and organic solvents!
‣ Wear protective goggles and safety gloves.
‣ Clean away splashes on clothes and other objects to prevent any damage.
‣ Pay particular attention to the information provided in the safety data sheets for the
chemicals used.
LWARNING
Hydrofluoric acid and mineral acids
Risk of serious or fatal injury from caustic burns
‣ Wear protective goggles to protect your eyes.
‣ Wear protective gloves and appropriate protective clothing.
‣ Avoid all contact with the eyes, mouth and skin.
‣ If using hydrofluoric acid, only use plastic vessels.
LWARNING
Thiocarbamide
Harmful if swallowed. Limited evidence of carcinogenicity. Possible risk of harm to the unborn
child. Dangerous for the environment with long-term effects.
‣ Wear protective goggles, protective gloves and appropriate protective clothing.
‣ Avoid all contact with the eyes, mouth and skin.
‣ Avoid releases into the environment.
26
Endress+Hauser
Indumax CLS50D/ CLS50
Maintenance
Clean away fouling on the sensor as follows depending on the type of fouling:
1.
Oily and greasy films:
Clean with grease remover, e.g. alcohol, as well as hot water and (alkaline) agents
containing surfactants (e.g. dishwashing detergent).
2.
Lime, cyanide and metal hydroxide buildup and low solubility organic buildup:
Dissolve buildup with diluted hydrochloric acid (3 %) and then rinse thoroughly with
plenty of clear water.
3.
Sulfidic buildup (from flue gas desulfurization or sewage treatment plants):
Use a mixture of hydrochloric acid (3 %) and thiocarbamide (commercially available)
and then rinse thoroughly with plenty of clear water.
4.
Buildup containing proteins (e.g. food industry):
Use a mixture of hydrochloric acid (0.5 %) and pepsin (commercially available) and then
rinse thoroughly with plenty of clear water.
5.
Readily soluble biological buildup:
Rinse with pressurized water.
After cleaning or regeneration, you must rinse the sensor thoroughly with water .
Endress+Hauser
27
Repair
Indumax CLS50D/ CLS50
8
Repair
8.1
Spare parts
Item No.
Spare parts kit
Order No.
150
150, 255
71086368
280
285
286
CHEMRAZ seal kit
• Nut (item 150)
• CHEMRAZ O-ring, 2 pcs. (item 255)
150, 250
71086369
260
270
VITON seal kit
• Nut (item 150)
• VITON O-ring, 3. pcs., (item 250)
260
PTFE disk kit for DN 50
71086372
270
PTFE disk kit for ANSI 2" and JIS 10K 50A
71086374
150, 280
Fixed flange kit, DN 50, stainless steel 1.4404 (AISI
316L)
• Nut (item 150)
• Flange DN 50 (item 280)
51500525
150, 285
Fixed flange kit, ANSI 2", stainless steel 1.4404 (AISI
316L)
• Nut (item 150)
• Flange ANSI 2" (item 285)
51500527
150, 286
Fixed flange kit, JIS, stainless steel 1.4404 (AISI 316L)
• Nut (item 150)
• Flange DN 50 (item 286)
51500934
150, 288,
292
Lap joint flange kit, ANSI 2", PVDF
• Nut (item 150)
• Flange ANSI 2", PVDF (item 288)
• Lap joint flange, UP-GF (item 292)
51500937
150, 287,
291
Lap joint flange kit, DN 50, PVDF
• Nut (item 150)
• Flange DN 50, PVDF (item 287)
• Lap joint flange, UP-GF (item 291)
51500936
150, 289,
293
Lap joint flange kit, JIS, PVDF
• Nut (item 150)
• Flange JIS, PVDF (item 289)
• Lap joint flange, UP-GF (item 293)
51500935
250
255
A0025483
291
292
293
150
287
288
289
260
270
250
255
A0025484
28
Endress+Hauser
Indumax CLS50D/ CLS50
8.2
Repair
Return
The product must be returned if repairs or a factory calibration are required, or if the wrong
product was ordered or delivered. As an ISO-certified company and also due to legal
regulations, Endress+Hauser is obliged to follow certain procedures when handling any
returned products that have been in contact with medium.
To ensure swift, safe and professional device returns, please read the return procedures and
conditions at www.endress.com/support/return-material.
8.3
Disposal
The device contains electronic components and must therefore be disposed of in accordance
with regulations on the disposal of electronic waste.
Observe the local regulations.
Endress+Hauser
29
Technical data
9
Technical data
9.1
Input
9.1.1
Measured variables
Indumax CLS50D/ CLS50
• Conductivity
• Temperature
9.1.2
Measuring ranges
Conductivity
Temperature
9.1.3
2 μS/cm to 2000 mS/cm (uncompensated)
-20 to +180 °C (-4 to +350 °F)
Cell constant
k = 1.98 cm–1
9.1.4
Measuring frequency
2 kHz
9.1.5
Temperature measurement
CLS50D
Pt1000 (Class A according to IEC 60751)
CLS50
Pt100 (Class A according to IEC 60751)
9.2
Performance characteristics
9.2.1
Conductivity response time
t95 ≤ 2 s
9.2.2
Temperature response time
PEEK version:
PFA version:
9.2.3
Maximum measured error
-20 to 100 °C (-4 to 212 °F):
> 100 °C (212 °F):
9.2.4
t90 ≤ 7 min
t90 ≤ 11 min
±(5 μS/cm + 0.5 % of reading)
±(10 μS/cm + 0.5 % of reading)
Repeatability
For T < 100 °C (212 °F): 0.2 % of reading + 1 µS/cm
For T > 100 °C (212 °F): 0.2 % of reading + 2 µS/cm
30
Endress+Hauser
Indumax CLS50D/ CLS50
9.2.5
Technical data
Linearity
1.9 % (only applies in the 1 to 20 mS/cm measuring range)
9.3
Environment
9.3.1
Ambient temperature
CLS50D
-10 to +60 °C (+10 to +140 °F)
CLS50
-10 to +70 °C (+10 to +160 °F)
9.3.2
Storage temperature
-20 to +80 °C (0 to +180 °F)
9.3.3
Degree of protection
IP 68 / NEMA type 6 (sensor in installed state with genuine seal)
9.4
Process
9.4.1
Process temperature
CLS50D
Sensor
material
CLS50D-*1/2
Without flange
CLS50D-*3/4/5/6/8
DN50, ANSI 2"
CLS50D-*7
JIS
CLS50D-*A/B/C
PVDF lap joint flange
PEEK
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
PFA
–20 to 110 °C
(-4 to 230 °F)
–20 to 110 °C
(-4 to 230 °F)
–20 to 110 °C
(-4 to 230 °F)
–20 to 110 °C
(-4 to 230 °F)
Sensor
material
CLS50-*1/2
Without flange
CLS50-*3/4/5/6/8
DN50, ANSI 2"
CLS50-*7
JIS
CLS50-*A/B/C
PVDF lap joint flange
PEEK
–20 to 180 °C
(-4 to 360 °F)
–20 to 180 °C
(-4 to 360 °F)
–20 to 180 °C
(-4 to 360 °F)
–20 to 125 °C
(-4 to 260 °F)
PFA
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
–20 to 125 °C
(-4 to 260 °F)
CLS50
9.4.2
Process pressure (absolute)
Max. 21 bar (305 psi), depending on the sensor version, see pressure-temperature ratings
Endress+Hauser
31
Technical data
9.4.3
Indumax CLS50D/ CLS50
Temperature-pressure ratings
CLS50D
p (abs.)
PFA Ex
[psi] [bar]
305
21
247
17
160
11
1
3
2
4
5
15
1
–20
0
+20
–4
+23
+68
40
60
80
100
125
[°C]
230 257
[°F]
110
T
A0024981
11
1
2
3
4
5
32
Pressure-temperature ratings CLS50D
PEEK sensor, without a flange
PFA sensor, without a flange (blue line)
PEEK or PFA sensor, with DN50/ANSI 2" flange (red line)
PEEK or PFA sensor, with JIS flange
PEEK or PFA sensor, with PVDF lap joint flange (green line)
Endress+Hauser
Indumax CLS50D/ CLS50
Technical data
CLS50
p (abs.)
[psi] [bar]
305
21
247
17
160
11
1
2
3
4
6
5
15
1
–20
0
+20
–4
+23
+68
40
60
80
100
125
T
140
257
160
180 [°C]
356 [°F]
A0024979
12
1
2
3
4
5
6
Pressure-temperature ratings for CLS50
PEEK sensor, without a flange
PFA sensor, without a flange or with DN50/ANSI 2" flange (blue line)
PEEK sensor, with DN50/ANSI 2" flange (red line)
PFA sensor, with JIS flange (black line)
PEEK or PFA sensor, with PVDF lap joint flange (green line)
PEEK sensor, with JIS flange (gray line)
9.5
Mechanical construction
9.5.1
Weight
Approx. 0.65 kg (1.43 lbs)
9.5.2
Materials
Sensor
PEEK, PFA (depending on version)
Sensor seal
VITON, CHEMRAZ (depending on version)
Endress+Hauser
33
Technical data
Indumax CLS50D/ CLS50
Process connections
G¾
CLS50D-*1B/C**: PEEK GF30
CLS50D-*1D**: stainless steel (AISI 316Ti)
CLS50-*1A*: stainless steel 1.4571 (AISI 316Ti)
CLS50-*1B/C/1/2/3: PEEK GF30
CLS50-*1B/C5/6: stainless steel 1.4571 (AISI 316Ti)
NPT 1"
PEEK
Fixed flange
Stainless steel 1.4404 (AISI 316L)
Sealing disk
GYLON (PTFE ceramic-filled)
Lap joint flange
PP-GF
Flange combined with lap joint flange
PVDF
9.5.3
•
•
•
•
•
•
•
•
Process connections
G¾ thread
NPT 1" thread
Lap joint flange EN 1092 DN50 PN10
Lap joint flange ANSI 2" 150 lbs
Lap joint flange JIS 10K 50A
Flange EN 1092-1 DN50 PN16
Flange ANSI 2" 300 lbs
Flange JIS 10K 50A
Flange dimensions
a
Øk
D
b
d2
d2
b
2
1
a
Øk
D
A0024986
13
1
2
34
Flange dimensions
Lap joint flange (PP-GF)
Fixed flange (stainless steel)
Endress+Hauser
Indumax CLS50D/ CLS50
Technical data
Dimensions in mm
Lap joint flange PP-GF
DN50 PN10
ANSI 2" 150 lbs
JIS 10K 50A
D
165
165
152
Øk
125
121
120
d2
4 x 18
8 x 19
4 x 19
b
18
18
18
a
78
78
78
Screws
M16
M16
M16
Fixed flange SS 316 L
DN50 PN10
ANSI 2" 300 lbs
JIS 10K 50A
D
165
165.1
155
Øk
125
127
120
d2
4 x 18
8 x 19
4 x 19
b
18
22.2
16
a
27
27
27
Screws
M16
M16
M16
Dimensions in mm
9.5.4
Chemical resistance
Medium
PEEK
PFA
CHEMRAZ
VITON
Sodium hydroxide 0 to 50 %
solution
NaOH
20 to 100 °C
(68 to 212 °F)
20 to 50 °C
(68 to 122 °F)
0 to 150 °C
(32 to 302 °F)
Not suitable
Nitric acid
HNO3
0 to 10 %
20 to 100 °C
(68 to 212 °F)
20 to 80 °C
(68 to 176 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
0 to 40 %
20 °C (68 °F)
20 to 60 °C
(68 to 140 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
Phosphoric acid
H3PO4
0 to 80 %
20 to 100 °C
(68 to 212 °F)
20 to 60 °C
(68 to 140 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
Sulfuric acid
H2SO4
0 to 2.5 %
20 to 80 °C
(68 to 176 °F)
20 to 100 °C
(68 to 212 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
0 to 30 %
20 °C (68 °F)
20 to 100 °C
(68 to 212 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
0 to 5 %
20 to 100 °C
(68 to 212 °F)
20 to 80 °C
(68 to 176 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
0 to 10 %
20 to 100 °C
(68 to 212 °F)
20 to 80 °C
(68 to 176 °F)
0 to 150 °C
(32 to 302 °F)
0 to 120 °C
(32 to 248 °F)
Hydrochloric acid
HCl
Endress+Hauser
Concentration
35
EU Declaration of conformity
10
EU Declaration of conformity
10.1
CLS50D-BA****
36
Indumax CLS50D/ CLS50
Endress+Hauser
Indumax CLS50D/ CLS50
10.2
EU Declaration of conformity
CLS50-G***
Endress+Hauser
37
EU Declaration of conformity
10.3
38
Indumax CLS50D/ CLS50
CLS50D-BV****
Endress+Hauser
Indumax CLS50D/ CLS50
10.4
EU Declaration of conformity
CLS50-V***
Endress+Hauser
39
Index
Index
A
M
Air set . . . . . . . . . . . . . . . . . . . . . . . . 15
Ambient temperature . . . . . . . . . . . . . . . 31
Assembly . . . . . . . . . . . . . . . . . . . . . . 19
Materials . . . . . . . . . .
Maximum measured error
Measured variables . . . .
Measuring frequency . . .
Measuring ranges . . . . .
C
Cable extension . . . . . . . . . . . . . . . . . . .
Cell constant . . . . . . . . . . . . . . . . . . . .
Check
Connection . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . .
Chemical resistance . . . . . . . . . . . . . . . .
Conductivity response time . . . . . . . . . . . .
Connection
Check . . . . . . . . . . . . . . . . . . . . .
Ensuring the degree of protection . . . . .
Connection conditions . . . . . . . . . . . . . . .
25
30
25
19
35
30
25
25
20
D
Declaration of Conformity . . . . . . . . . . 13, 36
Degree of protection
Ensuring . . . . . . . . . . . . . . . . . . . . 25
Technical data . . . . . . . . . . . . . . . . 31
Designated use . . . . . . . . . . . . . . . . . . . . 4
Direct connection to transmitter . . . . . . . . . 24
Disposal . . . . . . . . . . . . . . . . . . . . . . . 29
E
EC Declaration of Conformity . . . . . . . . . . .
Electrical connection . . . . . . . . . . . . . . . .
Environment . . . . . . . . . . . . . . . . . . . .
Ex approvals . . . . . . . . . . . . . . . . . . . .
36
19
31
13
F
Flange . . . . . . . . . . . . . . . . . . . . . . . . 16
H
Hazardous areas . . . . . . . . . . . . . . . . . . . 5
I
Incoming acceptance . . . . . . . . . . . . . . . . 9
Installation . . . . . . . . . . . . . . . . . . . . . 14
Installation factor . . . . . . . . . . . . . . . . . 15
L
Linearity . . . . . . . . . . . . . . . . . . . . . . . 31
40
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
33
30
30
30
30
Nameplate . . . . . . . . . . . . . . . . . . . . .
12
N
O
Operational safety . . . . . . . . . . . . . . . . . . 5
Orientation . . . . . . . . . . . . . . . . . . . . . 14
P
Performance characteristics . . . . . . . . . . .
Post-installation check . . . . . . . . . . . . . .
Pressure-temperature ratings . . . . . . . . . .
Process . . . . . . . . . . . . . . . . . . . . . . . .
Process connections . . . . . . . . . . . . . . . .
Process pressure . . . . . . . . . . . . . . . . . .
Process temperature . . . . . . . . . . . . . . . .
Product identification . . . . . . . . . . . . . . .
Product safety . . . . . . . . . . . . . . . . . . . .
30
19
32
31
34
31
31
12
5
R
Repair . . . . . . . . . . . . . . . . . . . . . . . . 28
Repeatability . . . . . . . . . . . . . . . . . . . . 30
Return . . . . . . . . . . . . . . . . . . . . . . . . 29
S
Safety
Electrical equipment in hazardous areas . . 5
Operation . . . . . . . . . . . . . . . . . . . . 5
Product . . . . . . . . . . . . . . . . . . . . . 5
Workplace safety . . . . . . . . . . . . . . . 4
Safety instructions . . . . . . . . . . . . . . . . . . 4
Scope of delivery . . . . . . . . . . . . . . . . . . 12
Sensor
Cleaning . . . . . . . . . . . . . . . . . . . . 26
Connecting . . . . . . . . . . . . . . . . . . 24
Connection in hazardous area . . . . . . . 20
Mounting . . . . . . . . . . . . . . . . . . . 16
State of the art . . . . . . . . . . . . . . . . . . . . 5
Storage temperature . . . . . . . . . . . . . . . . 31
Symbols . . . . . . . . . . . . . . . . . . . . . . . . 3
Endress+Hauser
Index
T
Technical data
Environment . . . . . . . . . . . . . . . . . 31
Input . . . . . . . . . . . . . . . . . . . . . . 30
Mechanical construction . . . . . . . . . . 33
Performance characteristics . . . . . . . . 30
Process . . . . . . . . . . . . . . . . . . . . . 31
Temperature measurement . . . . . . . . . . . . 30
Temperature response time . . . . . . . . . . . . 30
Temperature-pressure ratings . . . . . . . . . . 32
Type code . . . . . . . . . . . . . . . . . . . . . . . 9
U
Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
W
Warnings . . . . . . . . . . . . . . . . . . . . . . . 3
Weight . . . . . . . . . . . . . . . . . . . . . . . . 33
Workplace safety . . . . . . . . . . . . . . . . . . 4
Endress+Hauser
41
*71325826*
71325826
www.addresses.endress.com