Endress + Hauser Operating Instructions Indumax CLS50D/ CLS50 Digital sensor with Memosens protocol or analog sensor
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
BA00182C/07/EN/18.16 71325826 Products Solutions Services Operating Instructions Indumax CLS50D/ CLS50 Digital sensor with Memosens protocol or analog sensor For inductive measurement of conductivity in liquids 0 Table of contents Table of contents 1 Document information . . . . . . . . . 3 1.1 1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Basic safety instructions . . . . . . . 4 2.1 2.2 2.3 2.4 2.5 Requirements for personnel . . . . . . . . . . . Designated use . . . . . . . . . . . . . . . . . . . . . . Workplace safety . . . . . . . . . . . . . . . . . . . . Operational safety . . . . . . . . . . . . . . . . . . . Product safety . . . . . . . . . . . . . . . . . . . . . . . 3 Incoming acceptance and product identification . . . . . . . . . . 9 3.1 3.2 3.3 3.4 Incoming acceptance . . . . . . . . . . . . . . . . . 9 Product identification . . . . . . . . . . . . . . . . . 9 Scope of delivery . . . . . . . . . . . . . . . . . . . . 12 Certificates and approvals . . . . . . . . . . . . 13 4 Installation . . . . . . . . . . . . . . . . . . . . 14 4.1 4.2 4.3 Installation conditions . . . . . . . . . . . . . . . 14 Mounting the sensor . . . . . . . . . . . . . . . . 16 Post-installation check . . . . . . . . . . . . . . . 19 4 4 4 5 5 5 Electrical connection . . . . . . . . . . 19 5.1 5.2 5.3 5.4 Connection conditions . . . . . . . . . . . . . . . Connecting the sensor . . . . . . . . . . . . . . . Ensuring the degree of protection . . . . . Post-connection check . . . . . . . . . . . . . . . 6 Commissioning . . . . . . . . . . . . . . . . 26 7 Maintenance . . . . . . . . . . . . . . . . . . 26 20 24 25 25 8 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8.1 8.2 8.3 Spare parts . . . . . . . . . . . . . . . . . . . . . . . . 28 Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 9 Technical data . . . . . . . . . . . . . . . . . 30 10 EU Declaration of conformity . . . . . . . . . . . . . . . . . . . . . 36 10.1 10.2 10.3 10.4 CLS50D-BA**** . . . . . . . . . . . . . . . . . . . . CLS50-G*** . . . . . . . . . . . . . . . . . . . . . . . CLS50D-BV**** . . . . . . . . . . . . . . . . . . . . CLS50-V*** . . . . . . . . . . . . . . . . . . . . . . . 2 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 36 37 38 39 Endress+Hauser Indumax CLS50D/ CLS50 Document information 1 Document information 1.1 Warnings Structure of information LDANGER Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action LWARNING Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action LCAUTION Causes (/consequences) Consequences of non-compliance (if applicable) ‣ Corrective action NOTICE Meaning This symbol alerts you to a dangerous situation. Failure to avoid the dangerous situation will result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid the dangerous situation can result in a fatal or serious injury. This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or more serious injuries. This symbol alerts you to situations which may result in damage to property. Cause/situation Consequences of non-compliance (if applicable) ‣ Action/note 1.2 Symbols Symbol Meaning Additional information, tips Permitted or recommended Not permitted or not recommended Reference to device documentation Reference to page Reference to graphic  Endress+Hauser Result of a step 3 Basic safety instructions 2 Basic safety instructions 2.1 Requirements for personnel Indumax CLS50D/ CLS50 • Installation, commissioning, operation and maintenance of the measuring system may be carried out only by specially trained technical personnel. • The technical personnel must be authorized by the plant operator to carry out the specified activities. • The electrical connection may be performed only by an electrical technician. • The technical personnel must have read and understood these Operating Instructions and must follow the instructions contained therein. • Measuring point faults may be repaired only by authorized and specially trained personnel. Repairs not described in the Operating Instructions provided may only be carried out directly by the manufacturer or by the service organization. 2.2 Designated use Indumax CLS50/CLS50D is particularly suitable for use in the chemical industry and process engineering. The six-decade measuring range and the excellent chemical resistance properties of the materials in contact with the medium (PFA or PEEK) make it possible to use this sensor in a wide ranges of applications, such as: • Concentration measurement of acids and bases • Quality monitoring of chemical products in tanks and pipes • Phase separation of product/product mixtures The CLS50D digital sensor is used with Liquiline CM44x or Liquiline M CM42, while the CLS50 analog sensor is used with the Liquiline M CM42, Liquisys CLM223/253 or Mycom CLM153 transmitters. Use of the device for any purpose other than that described, poses a threat to the safety of people and of the entire measuring system and is therefore not permitted. The manufacturer is not liable for damage caused by improper or non-designated use. NOTICE Non-designated use Incorrect measurements, malfunctions and even measuring point failure could result ‣ Only use the product in accordance with the product specifications. ‣ Pay particular attention to the technical data on the nameplate. 2.3 Workplace safety As the user, you are responsible for complying with the following safety conditions: • Installation guidelines • Local standards and regulations • Regulations for explosion protection 4 Endress+Hauser Indumax CLS50D/ CLS50 Basic safety instructions Electromagnetic compatibility • The product has been tested for electromagnetic compatibility in accordance with the applicable European standards for industrial applications. • The electromagnetic compatibility indicated applies only to a product that has been connected in accordance with these Operating Instructions. 2.4 Operational safety 1. Before commissioning the entire measuring point, verify that all connections are correct. Ensure that electrical cables and hose connections are undamaged. 2. Do not operate damaged products, and safeguard them to ensure that they are not operated inadvertently. Label the damaged product as defective. 3. If faults cannot be rectified: Take the products out of operation and safeguard them to ensure that they are not operated inadvertently. 2.5 Product safety 2.5.1 State of the art The product is designed to meet state-of-the-art safety requirements, has been tested, and left the factory in a condition in which it is safe to operate. The relevant regulations and European standards have been observed. 2.5.2 Electrical equipment in hazardous areas Sensors with ATEX approval (CLS50-G*** and CLS50D-BA**** for Zone 0, CLS50-V*** and CLS50D-BV**** for Zone 2) have been developed and manufactured in compliance with applicable European standards and guidelines and are suitable for use in hazardous locations. The Declaration of Conformity confirms compliance with the harmonized European standards for using the sensors in hazardous areas. CLS50D-BA****, CLS50D-IA****, CLS50D-GB****, CLS50D-NA****, CLS50D-H****, CLS50-G*** and CLS50-K*** • The sensors may be operated in an environment specified as Ex Zone 0 (1G). • The sensors may only be used in liquid media with a conductivity >10 nS/cm. • If the connecting cable runs through Ex Zone 0 (1G), it must be protected against electrostatic charge. CLS50D-BA****, CLS50D-IA****, CLS50D-NA**** and CLS50D-GB**** • The sensor is a digital sensor with the Memosens protocol and its connection values are those specified below. • The sensor may also be connected to the intrinsically safe Memosens connection of the FSDG1 module of the Liquiline transmitter, types CM42-LE, CM42-LF, CM42-LI, EC typeexamination certificate EX5 05 03 30266 012 (ATEX or IECEx) or CM42-LK (EAC Ex). • The maximum permitted length of the measuring cable is 100 m (330 ft) here. Endress+Hauser 5 Basic safety instructions Indumax CLS50D/ CLS50 Connection values of the CLS50D-BA****, CLS50D-IA**** and CLS50D-GB**** sensor Ui 5.1 V Ii 130 mA Pi 166 mW Ci 18 µF Li 72 µH Temperature classes of CLS50D-BA****, CLS50D-IA**** and CLS50D-GB**** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50D-BA/IA/ GB*D** CLS50D-BA/IA/ GB*C** CLS50D-BA/IA/ GB*B** -20 to +60 ˚C -20 to +60 ˚C -20 to +60 ˚C -20 to +110 ˚C -20 to +120 ˚C -20 to +120 ˚C T6 CLS50D-BA/IA/ GB*D** CLS50D-BA/IA/ GB*C** CLS50D-BA/IA/ GB*B** -20 to +60 ˚C -20 to +60 ˚C -20 to +60 ˚C -20 to +70 ˚C -20 to +70 ˚C -20 to +70 ˚C CLS50-G*** • The sensor may only be connected to the following transmitters: – Liquiline types CM42-IG, CM42-IE, CM42-IF, EC type-examination certificate TÜV 13 ATEX 7459 X – Mycom type CLM153-Z with transmitter module type FCL1, EC type-examination certificate DMT 99 ATEX E 076 – Mycom type CLM153-G, EC type-examination certificate DMT 01 ATEX E 174 • The maximum permitted length of the measuring cable is 55 m (180 ft) here. Temperature classes of CLS50-G*** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50-G*** -20 to +125 ˚C -20 to +125 ˚C T6 CLS50-G*** -20 to +75 ˚C -20 to +75 ˚C CLS50D-BV**** and CLS50-V*** • The sensor may be operated in an environment specified as Ex Zone 2 (3G). • The sensor may only be connected to the following transmitter: Liquiline type CM42-LV (CLS50D) or CM42-IV (CLS50), EU Declaration of Conformity EC_00143_01.16 • Only CLS50-V***: The maximum permitted length of the measuring cable is 55 m (180 ft) here. 6 Endress+Hauser Indumax CLS50D/ CLS50 Basic safety instructions Temperature classes of CLS50D-BV**** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50D-BV*D** CLS50D-BV*C** CLS50D-BV*B** -20 to +60 ˚C -20 to +60 ˚C -20 to +60 ˚C -20 to +110 ˚C -20 to +120 ˚C -20 to +120 ˚C T6 CLS50D-BV**** -20 to +60 ˚C -20 to +70 ˚C Temperature classes of CLS50-V*** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50-V*** -20 to +125 ˚C -20 to +125 ˚C T6 CLS50-V*** -20 to +75 ˚C -20 to +75 ˚C CLS50-K*** • The sensor may only be connected to the following transmitter: Liquiline type CM42-IK • The maximum permitted length of the measuring cable is 55 m (180 ft) here. Temperature classes of CLS50-K*** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50-K*** -20 to +125 ˚C -20 to +125 ˚C T6 CLS50-K*** -20 to +75 ˚C -20 to +75 ˚C Sensors with FM and CSA approval (CLS50D-FB****, CLS50D-C2****, CLS50-O***, CLS50-S***) Observe the documentation and the control drawings of the transmitter. Sensors with NEPSI approval (CLS50D-NA**** and CLS50-H*** for Zone 0, CLS50-V*** for Zone 2) Pay attention to the information on the NEPSI certificates. You can download these certificates from the product page: www.endress.com/cls50d or www.endress.com/cls50. Temperature classes of CLS50D-NA**** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50D-NA*D** CLS50D-NA*C** CLS50D-NA*B** -20 to +60 ˚C -20 to +60 ˚C -20 to +60 ˚C -20 to +110 ˚C -20 to +120 ˚C -20 to +120 ˚C T6 CLS50D-NA*D** CLS50D-NA*C** CLS50D-NA*B** -20 to +60 ˚C -20 to +60 ˚C -20 to +60 ˚C -20 to +70 ˚C -20 to +70 ˚C -20 to +70 ˚C Endress+Hauser 7 Basic safety instructions Indumax CLS50D/ CLS50 Temperature classes of CLS50-H*** Temperature class Sensor Ambient temperature range Ta Medium temperature range Tmed T4 CLS50-H*** -20 to +125 ˚C -20 to +125 ˚C T6 CLS50-H*** -20 to +75 ˚C -20 to +75 ˚C Sensors with TIIS approval (CLS50D-TA****, CLS50-T***) Sensors with TIIS approval may only be used in a Zone 1 (2G) environment. The following also applies for all the sensors listed • Compliance with the specified ambient and medium temperature ranges is a prerequisite for safe use. • The sensor must be connected and operated in accordance with the Operating Instructions of the sensor and of the transmitter to be connected. All sensor operating data must be observed. • Avoid electrostatic charge. Metal process connections must be electrostatically connected (R ≤ 1 MΩ). • Non-metal process connections must be protected against electrostatic charge. • In order to avoid electrostatic charge clean the sensor with a damp cloth only. • Full compliance with regulations for electrical systems in hazardous locations (EN60079-14) is mandatory when using the devices and sensors. • Ensure correct installation to maintain the housing protection type. (Use original seal. Fit cable entry properly. Tighten nut). • The degree of protection only applies when the flange is mounted. CLS50 only In the CLS50 sensor, the internal sensor circuits are connected with the shielded wire of the supply cable. When installing the CM42 or CLM153 transmitter, the shielding of the sensor cable must be connected to functional ground as prescribed. As a result, the intrinsically safe sensor circuits of CLS50 are also connected to ground. Therefore, the power supply of the transmitter must be galvanically isolated and connected to ground. The CM42 and CLM153 transmitters already have secure internal galvanic isolation and therefore safely separate the sensor circuit from the other circuits. 8 Endress+Hauser Indumax CLS50D/ CLS50 Incoming acceptance and product identification 3 Incoming acceptance and product identification 3.1 Incoming acceptance 1. Verify that the packaging is undamaged.  Notify your supplier of any damage to the packaging. Keep the damaged packaging until the matter has been settled. 2. Verify that the contents are undamaged.  Notify your supplier of any damage to the delivery contents. Keep the damaged products until the matter has been settled. 3. Check the delivery for completeness.  Check it against the delivery papers and your order. 4. Pack the product for storage and transportation in such a way that it is protected against impact and moisture.  The original packaging offers the best protection. The permitted ambient conditions must be observed (see "Technical data"). If you have any questions, please contact your supplier or your local sales center. 3.2 Product identification 3.2.1 Type code for versions with explosion protection Name Type Indumax CLS50D Version - BA For use in hazardous areas, ATEX II 1G Ex ia IIC T4/T6 Ga Name Type Indumax CLS50D Type Indumax CLS50D x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance Version - BV For use in hazardous areas, ATEX II 3G Ex ic IIC T4/T6 Gc Endress+Hauser x Version - IA For use in hazardous areas, IECEx Ex ia IIC T4/T6 Ga Name x x x x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance 9 Incoming acceptance and product identification Name Type Indumax CLS50D Version - NA For use in hazardous areas, NEPSI Ex ia IIC T4/T6 Ga Name Type Indumax CLS50D Type Indumax CLS50D - C2 Type Indumax CLS50D - FB Type Indumax CLS50D - GB Type Indumax CLS50 - TA + x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance x B/C/ x D x + x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x x + x x Process connections, materials, cable connection, calibration, service No Ex relevance Version - G For use in hazardous areas, ATEX II 1G Ex ia IIC T4/T6 Ga 10 x Version For use in hazardous areas, TIIS Ex ib IIC T4 Gb Name x Version For use in hazardous areas, EAC Ex, 0Ex ia IIC T6/T4 Ga X Name x Version For use in hazardous areas, FM IS NI C1.I Div.1&2, Gr. A-D Name x Version For use in hazardous areas, CSA IS NI Cl.I Div.1&2,Gr. A-D Name Indumax CLS50D/ CLS50 x x x Process connections, materials, cable connection, calibration, service No Ex relevance Endress+Hauser Indumax CLS50D/ CLS50 Name Type Indumax CLS50 Incoming acceptance and product identification Version - V For use in hazardous areas, ATEX II 3G Ex ic IIC T4/T6 Gc / NEPSI Ex ic IIC T4/T6 Gc Name Type Indumax CLS50 Type Indumax CLS50 - H Type Indumax CLS50 - O Type Indumax CLS50 - S Type Indumax CLS50 x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x Process connections, materials, cable connection, calibration, service No Ex relevance x x x Process connections, materials, cable connection, calibration, service No Ex relevance Version - K For use in hazardous areas, EAC Ex, 0Ex ia IIC T6/T4 Ga X Endress+Hauser x Version - T For use in hazardous areas, TIIS Ex ib IIC T4 Gb Name Process connections, materials, cable connection, calibration, service No Ex relevance Version For use in hazardous areas, CSA IS NI Cl.I Div.1&2,Gr. A-D Name x Version For use in hazardous areas, FM IS NI Cl.I Div.1&2,Gr. A-D Name x Version For use in hazardous areas, NEPSI Ex ia IIC T4/T6 Ga Name x x x 1/2 / 3/4 Process connections, materials, cable connection, calibration, service No Ex relevance 11 Incoming acceptance and product identification 3.2.2 Indumax CLS50D/ CLS50 Nameplate The nameplate provides you with the following information on your device: • Manufacturer identification • Extended order code • Serial number • Safety information and warnings • Cell constant (nominal value) • Protection class • Ex labeling on hazardous area versions ‣ Compare the data on the nameplate with your order. 3.2.3 Product identification Product page www.endress.com/cls50d www.endress.com/cls50 Interpreting the order code The order code and serial number of your product can be found in the following locations: • On the nameplate • In the delivery papers Obtaining information on the product 1. Go to the product page for your product on the Internet. 2. At the bottom of the page, select the "Online Tools" link followed by "Check your device features".  An additional window opens. 3. Enter the order code from the nameplate into the search field, and then select "Show details".  You will receive information on each feature (selected option) of the order code. Manufacturer's address Endress+Hauser Conducta GmbH+Co. KG Dieselstraße 24 D-70839 Gerlingen 3.3 Scope of delivery The scope of delivery includes: • Sensor in the version ordered • Operating Instructions If you have any questions, please contact your supplier or your local sales center. 12 Endress+Hauser Indumax CLS50D/ CLS50 3.4 Certificates and approvals 3.4.1  mark Incoming acceptance and product identification Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the  mark. 3.4.2 Ex approvals CLS50D-BA**** and CLS50-G*** ATEX II 1G Ex ia IIC T4/T6 Ga CLS50D-BV**** ATEX II 3G Ex ic IIC T4/T6 Gc CLS50D-IA**** IECEx Ex ia IIC T4/T6 Ga CLS50-V*** ATEX II 3G Ex ic IIC T4/T6 Gc + NEPSI Ex ic IIC T4/T6 Gc CLS50D-NA**** and CLS50-H*** NEPSI Ex ia IIC T4/T6 Ga CLS50D-FB**** and CLS50-O*** FM IS NI Cl.I Div.1&2,G. A-D CLS50D-C2**** and CLS50-S*** CSA IS NI Cl.I Div.1&2,Gr. A-D CLS50D-TA**** and CLS50-T*** TIIS Ex ib IIC T4 Gb CLS50D-GB**** and CLS50-K*** • EAC Ex, 0Ex ia IIC T6/T4 Ga X • Zone 0 • Certificate number: TC RU C-DE.AA87.B.00088 and TC RU C-DE.ГБ05.B.00172 (only CLS50-K***) • The product has been certified in accordance with Directive TR CU 012/2011 which applies in the European Economic Area (EEA). The EAC conformity mark has been affixed to the product. 3.4.3 Certification body (only CLS50D-GB and CLS50-K) OOO "НАНИО ЦСВЭ" Russian Federation Endress+Hauser 13 Installation Indumax CLS50D/ CLS50 4 Installation 4.1 Installation conditions 4.1.1 Orientation When installing, align the sensor in such a way that the medium flows through the flow opening of the sensor in the direction of medium flow. The sensor head must be completely immersed in the medium. 2 a max. 100 (3.94) 1 A0024950 1 1 2 a 14 Sensor orientation, dimensions in mm (inch) Direction of medium flow Minimum water level in the pipe Distance from pipe wall Endress+Hauser Indumax CLS50D/ CLS50 4.1.2 Installation Installation factor In confined installation conditions, the conductivity measurement is affected by the pipe walls. The installation factor compensates for this effect. The transmitter corrects the cell constant by multiplying by the installation factor. The value of the installation factor depends on the diameter and the conductivity of the pipe nozzle as well as the sensor's distance to the wall. The installation factor f can be disregarded (f = 1.00) if the distance to the wall is sufficient (a > 15 mm (0.59"), from DN 80). If the distance to the wall is smaller, the installation factor increases for electrically insulating pipes (f > 1) and decreases for electrically conductive pipes (f < 1). It can be measured using calibration solutions, or a close approximation determined from the following diagram. f 1.40 2 1.20 1.00 1 0.80 0 5 10 15 20 0.20 0.39 0.59 0.79 25 a [mm] 0.98 a [inch] A0005441 2 1 2 Relationship between installation factor f and wall distance Electrically conductive pipe wall Electrically insulating pipe wall 4.1.3 Air set CLS50D The digital sensor has already been adjusted at the factory. Onsite compensation is not required. CLS50 To compensate residual coupling in the cable and between the two sensor coils, zero adjustment in air ("air set") must be performed before installing the sensor. Follow the instructions provided in the Operating Instructions of the transmitter used. Endress+Hauser 15 Installation Indumax CLS50D/ CLS50 4.2 Mounting the sensor 4.2.1 Installation with flange The sensor is suitable for installation in T-pieces ≥ DN 80, with the outgoing diameter reduced to ≥ DN 50. LWARNING Leakage Risk of injury if medium escapes ‣ Tighten the sensor nut with a torque of 20 Nm. ‣ To avoid leakages, regularly check the tightness of the nut. Flange, not in contact with medium 1 2 3 5 4 A0024949 3 1 2 3 4 5 16 Fixed flange, not in contact with medium (for order option: "Process connection" = 5, 6, 7) Flange (stainless steel) Nut Sealing disk (GYLON) O-ring Sensor Endress+Hauser Indumax CLS50D/ CLS50 Installation Flange, in contact with medium 1 2 4 3 A0024953 4 1 2 3 4 Fixed flange, in contact with medium (for order option: "Process connection" = 3, 4) Flange (stainless steel) Nut O-ring Sensor Endress+Hauser 17 Installation Indumax CLS50D/ CLS50 Lap joint flange, not in contact with medium 1 2 5 3 4 A0024954 5 1 2 3 4 5 18 Lap joint flange, not in contact with medium (for order option: "Process connection" = A, B, C) Lap joint flange (PP-GF) Nut (stainless steel) Flange (PVDF) O-ring Sensor Endress+Hauser Indumax CLS50D/ CLS50 4.2.2 Electrical connection Installation in assembly 1 2 3 4 A0024960 6 1 2 3 4 4.3 Installation of sensor with assembly CLA111 with suspension bracket CLA111 with flange connection CLA140 with flange connection CYA112 Post-installation check Put the sensor into operation only if you can answer "yes" to the following questions: • Are the sensor and cable undamaged? • Have you observed the correct orientation (arrow on the threaded sleeve=flow direction=installation direction)? • Has the sensor been installed in the process connection, and does not suspend freely from the cable? 5 Electrical connection LWARNING Device is live Incorrect connection may result in injury or death ‣ The electrical connection may be performed only by an electrical technician. ‣ The electrical technician must have read and understood these Operating Instructions and must follow the instructions contained therein. ‣ Prior to commencing connection work, ensure that no voltage is present on any cable. Endress+Hauser 19 Electrical connection Indumax CLS50D/ CLS50 5.1 Connection conditions 5.1.1 Connection diagram: sensors for Zone 0 (ATEX/EAC Ex) II 3G Zone 2 EX Zone 1 II 2G EX Ex ia II 1G Zone 0 Ex ia CLS50D-BA CLS50-G CLS50-G A0013258 20 Endress+Hauser Indumax CLS50D/ CLS50 5.1.2 Electrical connection Connection diagram: sensors for Zone 0 (IECEx) EX 9 Zone 1 II 2G EX II 1G Zone 0 Ex ia CLS50D-IA A0025482 Endress+Hauser 21 Electrical connection 5.1.3 Indumax CLS50D/ CLS50 Connection diagram: sensors for Zone 0 (NEPSI) EX 9 Zone 1 II 2G EX II 1G Zone 0 Ex ia CLS50D-NA CLS50-H A0025481 22 Endress+Hauser Indumax CLS50D/ CLS50 5.1.4 Electrical connection Connection diagram: sensors for Zone 2 (ATEX/NEPSI) EX 4...20 mA Ex ic CLS50D-BV Zone 2 II 3G EX CLS50-V A0010316 5.1.5 Sensors with FM or CSA approval The instructions in the Control Drawing apply for sensors with FM or CSA approval. You can find the Control Drawing in the Operating Instructions of the transmitter used. Endress+Hauser 23 Electrical connection Indumax CLS50D/ CLS50 5.2 Connecting the sensor 5.2.1 Direct connection, e.g. to CM42 CM42 Sensor cable Sensor CM42 Cable Sensor RD 187 188 197 BN WH GN U+ 215 U– 216 Com A 112 Com B 113 BU RD GN J 198 YE 387 111 388 218 WH YE RD WH 587 217 BU 588 A0001078 7 24 CLS50D to CM42 A0001082 8 CLS50 to CM42 Endress+Hauser Indumax CLS50D/ CLS50 5.2.2 Electrical connection Cable extension The sensor is supplied with a fixed cable. The cable between the sensor and transmitter can be extended using the CYK11 (CLS50D) or CLK6 (CLS50) special measuring cable (does not apply for use in a hazardous environment). WH U BN GN YE GY PK RD BU RD BU Shield U+ WH Memosens RD Com A Com B + GN WH YE BN n.c. Additional sensor supply Pt 100 GY A0017984 9 CYK11 for extension for CLS50D Max. total cable length: 100 m (330 ft) A002493  10 CLK6 for extension for CLS50 Max. total cable length: 55 m (180 ft) CLS50 only: The residual coupling of the sensor increases when the fixed cable is extended. 5.3 Ensuring the degree of protection Only the mechanical and electrical connections which are described in these instructions and which are necessary for the required, designated use, may be carried out on the device delivered. ‣ Exercise care when carrying out the work. Otherwise, the individual types of protection (Ingress Protection (IP), electrical safety, EMC interference immunity) agreed for this product can no longer be guaranteed due, for example, to covers being left off or cable (ends) which are loose or insufficiently secured. 5.4 Post-connection check Device condition and specifications Notes Are the outside of the sensor, assembly, cable undamaged? Visual inspection Electrical connection Notes Are the installed cables strain-relieved and not twisted? Is a sufficient length of the cable cores stripped, and is it positioned in the terminal correctly? Check the fit (by pulling gently) Are all the screws terminals properly tightened? Tighten Are all cable entries mounted, tightened and leak-tight? For lateral cable entries, make sure the cables loop downwards to allow water to drip off Are all cable entries installed downwards or mounted laterally? Endress+Hauser 25 Commissioning 6 Indumax CLS50D/ CLS50 Commissioning Before first commissioning, check if: • the sensor is correctly installed • the electrical connection is correct. If using an assembly with automatic cleaning, check that the cleaning medium (e.g. water or air) is connected correctly. LWARNING Escaping process medium Risk of injury from high pressure, high temperatures or chemical hazards ‣ Before applying compressed air to an assembly with cleaning facility, make sure the connections are correctly fitted. ‣ Do not install the assembly in the process if you cannot make the correct connection reliably. 7 Maintenance LCAUTION Corrosive chemicals Danger of chemical burns to the eyes and skin. Danger of damage to clothing and equipment ‣ It is absolutely essential to protect the eyes and hands properly when working with acids, bases and organic solvents! ‣ Wear protective goggles and safety gloves. ‣ Clean away splashes on clothes and other objects to prevent any damage. ‣ Pay particular attention to the information provided in the safety data sheets for the chemicals used. LWARNING Hydrofluoric acid and mineral acids Risk of serious or fatal injury from caustic burns ‣ Wear protective goggles to protect your eyes. ‣ Wear protective gloves and appropriate protective clothing. ‣ Avoid all contact with the eyes, mouth and skin. ‣ If using hydrofluoric acid, only use plastic vessels. LWARNING Thiocarbamide Harmful if swallowed. Limited evidence of carcinogenicity. Possible risk of harm to the unborn child. Dangerous for the environment with long-term effects. ‣ Wear protective goggles, protective gloves and appropriate protective clothing. ‣ Avoid all contact with the eyes, mouth and skin. ‣ Avoid releases into the environment. 26 Endress+Hauser Indumax CLS50D/ CLS50 Maintenance Clean away fouling on the sensor as follows depending on the type of fouling: 1. Oily and greasy films: Clean with grease remover, e.g. alcohol, as well as hot water and (alkaline) agents containing surfactants (e.g. dishwashing detergent). 2. Lime, cyanide and metal hydroxide buildup and low solubility organic buildup: Dissolve buildup with diluted hydrochloric acid (3 %) and then rinse thoroughly with plenty of clear water. 3. Sulfidic buildup (from flue gas desulfurization or sewage treatment plants): Use a mixture of hydrochloric acid (3 %) and thiocarbamide (commercially available) and then rinse thoroughly with plenty of clear water. 4. Buildup containing proteins (e.g. food industry): Use a mixture of hydrochloric acid (0.5 %) and pepsin (commercially available) and then rinse thoroughly with plenty of clear water. 5. Readily soluble biological buildup: Rinse with pressurized water. After cleaning or regeneration, you must rinse the sensor thoroughly with water . Endress+Hauser 27 Repair Indumax CLS50D/ CLS50 8 Repair 8.1 Spare parts Item No. Spare parts kit Order No. 150 150, 255 71086368 280 285 286 CHEMRAZ seal kit • Nut (item 150) • CHEMRAZ O-ring, 2 pcs. (item 255) 150, 250 71086369 260 270 VITON seal kit • Nut (item 150) • VITON O-ring, 3. pcs., (item 250) 260 PTFE disk kit for DN 50 71086372 270 PTFE disk kit for ANSI 2" and JIS 10K 50A 71086374 150, 280 Fixed flange kit, DN 50, stainless steel 1.4404 (AISI 316L) • Nut (item 150) • Flange DN 50 (item 280) 51500525 150, 285 Fixed flange kit, ANSI 2", stainless steel 1.4404 (AISI 316L) • Nut (item 150) • Flange ANSI 2" (item 285) 51500527 150, 286 Fixed flange kit, JIS, stainless steel 1.4404 (AISI 316L) • Nut (item 150) • Flange DN 50 (item 286) 51500934 150, 288, 292 Lap joint flange kit, ANSI 2", PVDF • Nut (item 150) • Flange ANSI 2", PVDF (item 288) • Lap joint flange, UP-GF (item 292) 51500937 150, 287, 291 Lap joint flange kit, DN 50, PVDF • Nut (item 150) • Flange DN 50, PVDF (item 287) • Lap joint flange, UP-GF (item 291) 51500936 150, 289, 293 Lap joint flange kit, JIS, PVDF • Nut (item 150) • Flange JIS, PVDF (item 289) • Lap joint flange, UP-GF (item 293) 51500935 250 255 A0025483 291 292 293 150 287 288 289 260 270 250 255 A0025484 28 Endress+Hauser Indumax CLS50D/ CLS50 8.2 Repair Return The product must be returned if repairs or a factory calibration are required, or if the wrong product was ordered or delivered. As an ISO-certified company and also due to legal regulations, Endress+Hauser is obliged to follow certain procedures when handling any returned products that have been in contact with medium. To ensure swift, safe and professional device returns, please read the return procedures and conditions at www.endress.com/support/return-material. 8.3 Disposal The device contains electronic components and must therefore be disposed of in accordance with regulations on the disposal of electronic waste. Observe the local regulations. Endress+Hauser 29 Technical data 9 Technical data 9.1 Input 9.1.1 Measured variables Indumax CLS50D/ CLS50 • Conductivity • Temperature 9.1.2 Measuring ranges Conductivity Temperature 9.1.3 2 μS/cm to 2000 mS/cm (uncompensated) -20 to +180 °C (-4 to +350 °F) Cell constant k = 1.98 cm–1 9.1.4 Measuring frequency 2 kHz 9.1.5 Temperature measurement CLS50D Pt1000 (Class A according to IEC 60751) CLS50 Pt100 (Class A according to IEC 60751) 9.2 Performance characteristics 9.2.1 Conductivity response time t95 ≤ 2 s 9.2.2 Temperature response time PEEK version: PFA version: 9.2.3 Maximum measured error -20 to 100 °C (-4 to 212 °F): > 100 °C (212 °F): 9.2.4 t90 ≤ 7 min t90 ≤ 11 min ±(5 μS/cm + 0.5 % of reading) ±(10 μS/cm + 0.5 % of reading) Repeatability For T < 100 °C (212 °F): 0.2 % of reading + 1 µS/cm For T > 100 °C (212 °F): 0.2 % of reading + 2 µS/cm 30 Endress+Hauser Indumax CLS50D/ CLS50 9.2.5 Technical data Linearity 1.9 % (only applies in the 1 to 20 mS/cm measuring range) 9.3 Environment 9.3.1 Ambient temperature CLS50D -10 to +60 °C (+10 to +140 °F) CLS50 -10 to +70 °C (+10 to +160 °F) 9.3.2 Storage temperature -20 to +80 °C (0 to +180 °F) 9.3.3 Degree of protection IP 68 / NEMA type 6 (sensor in installed state with genuine seal) 9.4 Process 9.4.1 Process temperature CLS50D Sensor material CLS50D-*1/2 Without flange CLS50D-*3/4/5/6/8 DN50, ANSI 2" CLS50D-*7 JIS CLS50D-*A/B/C PVDF lap joint flange PEEK –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) PFA –20 to 110 °C (-4 to 230 °F) –20 to 110 °C (-4 to 230 °F) –20 to 110 °C (-4 to 230 °F) –20 to 110 °C (-4 to 230 °F) Sensor material CLS50-*1/2 Without flange CLS50-*3/4/5/6/8 DN50, ANSI 2" CLS50-*7 JIS CLS50-*A/B/C PVDF lap joint flange PEEK –20 to 180 °C (-4 to 360 °F) –20 to 180 °C (-4 to 360 °F) –20 to 180 °C (-4 to 360 °F) –20 to 125 °C (-4 to 260 °F) PFA –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) –20 to 125 °C (-4 to 260 °F) CLS50 9.4.2 Process pressure (absolute) Max. 21 bar (305 psi), depending on the sensor version, see pressure-temperature ratings Endress+Hauser 31 Technical data 9.4.3 Indumax CLS50D/ CLS50 Temperature-pressure ratings CLS50D p (abs.) PFA Ex [psi] [bar] 305 21 247 17 160 11 1 3 2 4 5 15 1 –20 0 +20 –4 +23 +68 40 60 80 100 125 [°C] 230 257 [°F] 110 T A0024981  11 1 2 3 4 5 32 Pressure-temperature ratings CLS50D PEEK sensor, without a flange PFA sensor, without a flange (blue line) PEEK or PFA sensor, with DN50/ANSI 2" flange (red line) PEEK or PFA sensor, with JIS flange PEEK or PFA sensor, with PVDF lap joint flange (green line) Endress+Hauser Indumax CLS50D/ CLS50 Technical data CLS50 p (abs.) [psi] [bar] 305 21 247 17 160 11 1 2 3 4 6 5 15 1 –20 0 +20 –4 +23 +68 40 60 80 100 125 T 140 257 160 180 [°C] 356 [°F] A0024979  12 1 2 3 4 5 6 Pressure-temperature ratings for CLS50 PEEK sensor, without a flange PFA sensor, without a flange or with DN50/ANSI 2" flange (blue line) PEEK sensor, with DN50/ANSI 2" flange (red line) PFA sensor, with JIS flange (black line) PEEK or PFA sensor, with PVDF lap joint flange (green line) PEEK sensor, with JIS flange (gray line) 9.5 Mechanical construction 9.5.1 Weight Approx. 0.65 kg (1.43 lbs) 9.5.2 Materials Sensor PEEK, PFA (depending on version) Sensor seal VITON, CHEMRAZ (depending on version) Endress+Hauser 33 Technical data Indumax CLS50D/ CLS50 Process connections G¾ CLS50D-*1B/C**: PEEK GF30 CLS50D-*1D**: stainless steel (AISI 316Ti) CLS50-*1A*: stainless steel 1.4571 (AISI 316Ti) CLS50-*1B/C/1/2/3: PEEK GF30 CLS50-*1B/C5/6: stainless steel 1.4571 (AISI 316Ti) NPT 1" PEEK Fixed flange Stainless steel 1.4404 (AISI 316L) Sealing disk GYLON (PTFE ceramic-filled) Lap joint flange PP-GF Flange combined with lap joint flange PVDF 9.5.3 • • • • • • • • Process connections G¾ thread NPT 1" thread Lap joint flange EN 1092 DN50 PN10 Lap joint flange ANSI 2" 150 lbs Lap joint flange JIS 10K 50A Flange EN 1092-1 DN50 PN16 Flange ANSI 2" 300 lbs Flange JIS 10K 50A Flange dimensions a Øk D b d2 d2 b 2 1 a Øk D A0024986  13 1 2 34 Flange dimensions Lap joint flange (PP-GF) Fixed flange (stainless steel) Endress+Hauser Indumax CLS50D/ CLS50 Technical data Dimensions in mm Lap joint flange PP-GF DN50 PN10 ANSI 2" 150 lbs JIS 10K 50A D 165 165 152 Øk 125 121 120 d2 4 x 18 8 x 19 4 x 19 b 18 18 18 a 78 78 78 Screws M16 M16 M16 Fixed flange SS 316 L DN50 PN10 ANSI 2" 300 lbs JIS 10K 50A D 165 165.1 155 Øk 125 127 120 d2 4 x 18 8 x 19 4 x 19 b 18 22.2 16 a 27 27 27 Screws M16 M16 M16 Dimensions in mm 9.5.4 Chemical resistance Medium PEEK PFA CHEMRAZ VITON Sodium hydroxide 0 to 50 % solution NaOH 20 to 100 °C (68 to 212 °F) 20 to 50 °C (68 to 122 °F) 0 to 150 °C (32 to 302 °F) Not suitable Nitric acid HNO3 0 to 10 % 20 to 100 °C (68 to 212 °F) 20 to 80 °C (68 to 176 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) 0 to 40 % 20 °C (68 °F) 20 to 60 °C (68 to 140 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) Phosphoric acid H3PO4 0 to 80 % 20 to 100 °C (68 to 212 °F) 20 to 60 °C (68 to 140 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) Sulfuric acid H2SO4 0 to 2.5 % 20 to 80 °C (68 to 176 °F) 20 to 100 °C (68 to 212 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) 0 to 30 % 20 °C (68 °F) 20 to 100 °C (68 to 212 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) 0 to 5 % 20 to 100 °C (68 to 212 °F) 20 to 80 °C (68 to 176 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) 0 to 10 % 20 to 100 °C (68 to 212 °F) 20 to 80 °C (68 to 176 °F) 0 to 150 °C (32 to 302 °F) 0 to 120 °C (32 to 248 °F) Hydrochloric acid HCl Endress+Hauser Concentration 35 EU Declaration of conformity 10 EU Declaration of conformity 10.1 CLS50D-BA**** 36 Indumax CLS50D/ CLS50 Endress+Hauser Indumax CLS50D/ CLS50 10.2 EU Declaration of conformity CLS50-G*** Endress+Hauser 37 EU Declaration of conformity 10.3 38 Indumax CLS50D/ CLS50 CLS50D-BV**** Endress+Hauser Indumax CLS50D/ CLS50 10.4 EU Declaration of conformity CLS50-V*** Endress+Hauser 39 Index Index A M Air set . . . . . . . . . . . . . . . . . . . . . . . . 15 Ambient temperature . . . . . . . . . . . . . . . 31 Assembly . . . . . . . . . . . . . . . . . . . . . . 19 Materials . . . . . . . . . . Maximum measured error Measured variables . . . . Measuring frequency . . . Measuring ranges . . . . . C Cable extension . . . . . . . . . . . . . . . . . . . Cell constant . . . . . . . . . . . . . . . . . . . . Check Connection . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . Chemical resistance . . . . . . . . . . . . . . . . Conductivity response time . . . . . . . . . . . . Connection Check . . . . . . . . . . . . . . . . . . . . . Ensuring the degree of protection . . . . . Connection conditions . . . . . . . . . . . . . . . 25 30 25 19 35 30 25 25 20 D Declaration of Conformity . . . . . . . . . . 13, 36 Degree of protection Ensuring . . . . . . . . . . . . . . . . . . . . 25 Technical data . . . . . . . . . . . . . . . . 31 Designated use . . . . . . . . . . . . . . . . . . . . 4 Direct connection to transmitter . . . . . . . . . 24 Disposal . . . . . . . . . . . . . . . . . . . . . . . 29 E EC Declaration of Conformity . . . . . . . . . . . Electrical connection . . . . . . . . . . . . . . . . Environment . . . . . . . . . . . . . . . . . . . . Ex approvals . . . . . . . . . . . . . . . . . . . . 36 19 31 13 F Flange . . . . . . . . . . . . . . . . . . . . . . . . 16 H Hazardous areas . . . . . . . . . . . . . . . . . . . 5 I Incoming acceptance . . . . . . . . . . . . . . . . 9 Installation . . . . . . . . . . . . . . . . . . . . . 14 Installation factor . . . . . . . . . . . . . . . . . 15 L Linearity . . . . . . . . . . . . . . . . . . . . . . . 31 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 30 30 30 30 Nameplate . . . . . . . . . . . . . . . . . . . . . 12 N O Operational safety . . . . . . . . . . . . . . . . . . 5 Orientation . . . . . . . . . . . . . . . . . . . . . 14 P Performance characteristics . . . . . . . . . . . Post-installation check . . . . . . . . . . . . . . Pressure-temperature ratings . . . . . . . . . . Process . . . . . . . . . . . . . . . . . . . . . . . . Process connections . . . . . . . . . . . . . . . . Process pressure . . . . . . . . . . . . . . . . . . Process temperature . . . . . . . . . . . . . . . . Product identification . . . . . . . . . . . . . . . Product safety . . . . . . . . . . . . . . . . . . . . 30 19 32 31 34 31 31 12 5 R Repair . . . . . . . . . . . . . . . . . . . . . . . . 28 Repeatability . . . . . . . . . . . . . . . . . . . . 30 Return . . . . . . . . . . . . . . . . . . . . . . . . 29 S Safety Electrical equipment in hazardous areas . . 5 Operation . . . . . . . . . . . . . . . . . . . . 5 Product . . . . . . . . . . . . . . . . . . . . . 5 Workplace safety . . . . . . . . . . . . . . . 4 Safety instructions . . . . . . . . . . . . . . . . . . 4 Scope of delivery . . . . . . . . . . . . . . . . . . 12 Sensor Cleaning . . . . . . . . . . . . . . . . . . . . 26 Connecting . . . . . . . . . . . . . . . . . . 24 Connection in hazardous area . . . . . . . 20 Mounting . . . . . . . . . . . . . . . . . . . 16 State of the art . . . . . . . . . . . . . . . . . . . . 5 Storage temperature . . . . . . . . . . . . . . . . 31 Symbols . . . . . . . . . . . . . . . . . . . . . . . . 3 Endress+Hauser Index T Technical data Environment . . . . . . . . . . . . . . . . . 31 Input . . . . . . . . . . . . . . . . . . . . . . 30 Mechanical construction . . . . . . . . . . 33 Performance characteristics . . . . . . . . 30 Process . . . . . . . . . . . . . . . . . . . . . 31 Temperature measurement . . . . . . . . . . . . 30 Temperature response time . . . . . . . . . . . . 30 Temperature-pressure ratings . . . . . . . . . . 32 Type code . . . . . . . . . . . . . . . . . . . . . . . 9 U Use . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 W Warnings . . . . . . . . . . . . . . . . . . . . . . . 3 Weight . . . . . . . . . . . . . . . . . . . . . . . . 33 Workplace safety . . . . . . . . . . . . . . . . . . 4 Endress+Hauser 41 *71325826* 71325826 www.addresses.endress.com