Analyzer Project FAT Supporting Docs Test records
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS PUNCH LIST Item Tag Problem Found Action Action by Complete 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 https://analyzedetectnetwork.com Sig Supplier Sig Purchaser Date INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS INSPECTION and TEST RECORD SHEET – Analyzer Enclosure Tag No: Date Tested: PASS 1. Visual Inspection 2. Check Tubing & Piping to ensure: 3. 4. a) Straightness b) Neatness c) Securely fastened d) Connections tight & ferrules fitted (check sample 10%) e) Correct size & material used, as per customer specification Sheet 1 FAIL                                                 COMMENTS Check Equipment mounted to ensure: a) Securely fastened b) Correct scales on gauges and flow meters c) Correct scales on gauges d) Correct labels fitted e) Correct client Cable dressing interface connections f) Bulkhead/cable entries secure and labelled g) Chains and hooks on cylinder racks h) Equipment straight/level i) Cable tray straight/level j) Unistrut straight/level Check electrical equipment to ensure: a) Correct certification b) Switches / MCB’s operate c) Terminal covers accessible d) Terminal screws tight e) Terminals and wires correctly marked f) Emergency light operates g) All cables identified correctly h) Equipment has path to ground Continued …. https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS INSPECTION and TEST RECORD SHEET – Analyzer Shelter PASS FAIL 5. Doors fit and close correctly   6. All drawings ‘As Built’   Sheet 2 COMMENTS Comments/Clarifications Witnessed by Signature: https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS Date: INSPECTION and TEST RECORD SHEET – Signal Cable Test Equipment S/N: Calibration Certificate No: CONTINUITY, CORE & EARTH LEAK TEST CABLE SUPPLY <=24VDC CABLE No. SERVICE CONTINUITY CORE TO EARTH TESTED BY https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS Witnessed by Signature: Date: https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS INSPECTION and TEST RECORD SHEET – Power Cable Test Equipment S/N: Calibration Certificate No: CONTINUITY, INSULATION, CORE & EARTH LEAK TEST MEGGER TEST VOLTAGE 500V - <50M NOT ACCEPTABLE CABLE No. SERVICE CONTINUITY MEGGER CORE TO EARTH MEGGER CORE TO CORE TESTED BY https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS Witnessed by Signature: Date: https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS INSPECTION and TEST RECORD SHEET – Power Cable Test Equipment S/N: Calibration Certificate No: FUNCTIONAL TEST DESCRIPTION ITEM TESTED Tag No: COMMENTS TESTED BY https://analyzedetectnetwork.com INSPECTION - FAT FORMS FOR ANALYZER SYSTEMS Witnessed by Signature: Date: https://analyzedetectnetwork.com