Welker® Adjustable Corrosion Coupon Probe Installation, Operation, Maintenance Manual
Industry Manual Repository
Join the AnalyzeDetectNetwork and Read This Manual and Hundreds of Others Like It! It's Free!
Installation, Operation, and
Maintenance Manual
Welker® Adjustable Corrosion Coupon Probe
Model
APM-4CC
Drawing No.: AD778BW
Manual No.: IOM-159
The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the
installation, operation, and maintenance of the Welker® equipment described above. Correct operating and/or installation
techniques, however, are the responsibility of the end user. Welker® reserves the right to make changes to this and all
products in order to improve performance and reliability.
This manual is intended to be used as a basic installation and operation guide for the Welker®
Adjustable Corrosion Coupon Probe, APM-4CC. For comprehensive instructions, please refer to the
IOM Manuals for each individual component. A list of relevant component IOM Manuals is given in
the Appendix section of this manual.
13839 West Bellfort
Sugar Land, TX 77498-1671
(281) 491-2331 - Office
(800) 776-7267 - USA Only
(281) 491-8344 - Fax
http://www.welkereng.com
©2012 Welker, Inc. All Rights Reserved.
TABLE OF CONTENTS
Welker®, Welker Jet®, and WelkerScope® are Registered Trademarks owned by Welker, Inc.
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 2 of 9
Section 1:
SPECIFICATIONS
We appreciate your business and your choice of Welker® products. The installation, operation, and
maintenance liability for this product becomes that of the purchaser at the time of receipt. Reading
the applicable Installation, Operation, and Maintenance (IOM) Manual prior to installation and
operation of this equipment is required for a full understanding of its application and performance
prior to use.*
If you have any questions, please call 1-800-776-7267 (USA) or 1-281-491-2331.
*The following procedures have been written for use with standard Welker® parts and equipment. Assemblies that
have been modified may have additional requirements and specifications that are not listed in this manual.
The Welker® Adjustable Corrosion Coupon Probe is designed to insert a corrosion coupon into a
pressurized pipeline. The probe length can be adjusted, using the stop and lock collars, to insert the
corrosion coupon attachment to the desired insertion depth.
The specifications listed in this section are generalized for this equipment. Welker® can
modify the equipment according to your company’s needs. However, please note that the
specifications may vary depending on the customization of your product.
Table 1: Product Specifications
Products Sampled
Gas or Liquid
Materials of Construction
316 Stainless Steel, Viton®, PTFE
Others available upon request.
Connections
1” NPT
Maximum Allowable Operating
Pressure
1440 psi @ -20o to 120oF
(99.3 bar @ -29o to 49oC)
Maximum Allowable Manual
Insertion & Retraction Pressure
For 5/8” Tubing: 160 psi (11.0 bar)
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 3 of 9
Figure 1: System Diagram
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 4 of 9
Section 2:
INSTALLATION & OPERATIONS
After unpacking the unit, check the equipment for compliance and for any damage that may
have occurred during shipment. Claims for damage caused during shipping must be
initiated by the receiver and directed to the shipping carrier. Welker® is not responsible
for any damage caused by mishandling by the shipping company.
When sealing fittings with PTFE tape, refer to the proper sealing instructions for the tape
used.
1. Welker® recommends the probe be threaded onto a full-open valve (hereafter, “pipeline isolation
valve”) which can be used to isolate the probe from pipeline pressure.
2. Handle the unit with care. Avoid bending the probe, which has a polished surface that travels
through seals.
3. Operate the unit slowly and smoothly while inserting and retracting to avoid unnecessary
slamming of the lock collar.
4. Be careful not to close the pipeline isolation valve on the probe while the probe is still inserted
into the pipeline. This is the most common cause of damage to Welker® probes.
1. Screw a customer-supplied corrosion coupon into the threaded opening of the coupon holder.
The corrosion coupon holder contains a Delrin® bearing to insulate the corrosion coupon
from electrical charges. Screw the coupon into the coupon holder gently to prevent damaging
the Delrin® bearing.
Positioning the stop collar (Figure 2):
2. Before installing the probe, the length the insertion probe will need to travel inside the pipeline
must be determined. Measure the distance the probe must travel from the top of the pipeline
isolation valve to the desired insertion depth (e.g., center 1/3 of the pipeline). This will be the
probe insertion length.
The desired insertion depth should be determined based on company policy and
standards. Ensure the corrosion coupon will not come into contact with the internal
sides or bottom of the pipeline when inserted.
3. Ensure that the probe is fully retracted. The corrosion coupon should be flush with the bottom of
the adapter.
4. Beginning at the top of the body, measure up on the probe from the bottom of the corrosion
coupon to the desired insertion length. It may help to mark this point with a felt-tip pen.
5. Loosen the two set screws in the stop collar, and move the bottom of the stop collar to the
desired probe insertion length, or the mark made in Step 4.
6. Tighten the set screws in the stop collar to hold the stop collar in place on the shaft.
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 5 of 9
Figure 2: Positioning the Stop Collar
Installing the Probe:
7. With the pipeline isolation valve closed and the probe shaft fully retracted, install the probe onto
the threaded connection on the pipeline isolation valve.
8. Ensure all valves are closed.
9. Slowly open the pipeline isolation valve.
10. Firmly push the shaft into the pipeline.
When pushing the shaft into the pipeline, push straight downward; do not allow the shaft to
bend. Do NOT insert the probe at pressures higher than the pressure specified in Table 1 of
these instructions.
11. Tighten the stop collar bolts to lock the stop collar in place. Continue to push downward on the
shaft until the stop collar is locked in place.
12. Check the system for leaks and repair as necessary.
Retracting the Probe:
13. Push downward on the unit, and simultaneously loosen the stop collar bolts.
Failure to maintain downward force on the probe unit while loosening the lock collar may
cause the probe to retract too quickly, possibly resulting in damage to the equipment or
injury of personnel.
14. Slowly allow pipeline pressure to push the probe shaft out of the pipeline. Gently pull up on the
probe shaft as needed until the probe is fully retracted.
Maintain downward pressure and allow the probe to retract slowly; do not allow the
shaft to bend. Do NOT retract the probe at pressures higher than the pressure specified
in Table 1 of these instructions.
15. Close the pipeline isolation valve.
Ensure the probe is fully retracted prior to closing the isolation valve. Failure to fully
retract the probe shaft prior to closing the isolation valve is the leading cause of damage to
Welker® probes.
16. Open the valve on the probe to relieve any remaining pressure from the probe.
17. Unscrew the unit from the pipeline threaded connection. The unit is now ready for maintenance
or to be moved to another location.
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 6 of 9
Section 3:
MAINTENANCE
1. Welker® recommends that the unit have annual maintenance under normal operating
conditions. In cases of severe service, dirty conditions, excessive usage, or other unique
applications that may lead to excess wear on the unit, a more frequent maintenance schedule may
be appropriate.
2. Prior to maintenance or disassembly of the unit, it is advisable to have a repair kit available for
repairs of the system in case of unexpected wear or faulty seals.
New seals supplied in spare parts kits are not lubricated. They should be lightly coated with
lubrication grease before installation. Welker® recommends Dow Corning 111 [DC 111] or
an equivalent lubricant for use with this unit.
3. All maintenance and cleaning of the unit should be done on a smooth, clean surface.
4. During system operation, check for leaks and repair as necessary.
5. Prior to maintenance, remove the unit from operation and retract the unit from the pipeline
(Section 2.2, Steps 13-17).
1. Loosen the lock collar and slide it down the shaft. Be careful with the pin, which is a small part
and may be easily lost.
2. Unscrew the base from the top of the shaft.
3. Replace the O-ring inside the base.
4. Slide the lock collar and pin off the end of the shaft.
5. Remove the stop collar bolts.
6. Loosen and remove the stop collar from the shaft.
7. Gently slide the probe shaft out of the body. Be careful not to bend or scratch the probe shaft.
8. Replace the wiper, O-ring, and back-up rings in the body.
9. Inspect the probe shaft for scratches, bending, or other damage. If the probe shaft is scratched or
otherwise damaged, polish or replace as necessary. The shaft may need to be replaced if it is bent
or deeply scratched.
10. Remove the coupon holder from the end of the probe shaft.
11. Replace the O-ring on the end of the probe shaft.
12. Reattach the coupon holder to the end of the probe shaft.
13. Gently slide the probe shaft through the body.
14. Reattach the stop collar to the probe shaft.
15. Reattach and tighten the lock collar and base to the end of the probe shaft. The probe is now
ready to be reinstalled.
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 7 of 9
Figure 3: Maintenance Diagram
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 8 of 9
APPENDIX
Welker® Installation, Operation, and Maintenance Manuals suggested for use with this unit:
None
Other Installation, Operation, and Maintenance Manuals suggested for use with this unit:
None
Welker® drawings and schematics suggested for use with this unit:
Assembly Drawing: AD778BW
13839 West Bellfort
Sugar Land, TX 77498-1671
Phone: (281) 491-2331
Fax: (281) 491-8344
Toll Free: (800) 776-7267
Web Page: www.welkereng.com
IOM-159
PART #: APM-4CC
Rev: -
Last Updated: 09/25/2012
Page 9 of 9